§ 37-619.6 — Site Plan Design Requirements
Code of Ordinances of the City of Champaign, Illinois (Codified through C.B. No. 2026-125, adopted August 18, 2026 (Supp. No. 81, Update 1)) · Champaign Code of Ordinances § 37-619.6
Corpus is an independent public-information project, not the official City of Champaign website. Stable reference: corpuslaw.us/code/1e504476-218f-411b-8f00-8ad736d1206b
Sec. 37-619.6. - Site Plan Design Requirements.
For any development within the Curtis Road Interchange Area Overlay District, a site plan is required to be submitted and shall be consistent with the approved Overall Development Plan. Any person or entity seeking approval of any development in the Curtis Road Interchange Area Overlay District shall comply with each of the requirements identified in Table XI-F. Property with SF-1 and SF-2 Zoning are not subject to Table XI-F: Design Requirements for the Curtis Road Interchange Area Overlay District. Where the standards differ between Table XI-F and other standards of Chapter 37 of the Champaign Municipal Code, Table XI-F will supersede the conflicting standard. Table XI-F Design Requirements for Curtis Road Interchange Area Overlay District Stage 2: Site Plan BUILDING DESIGN Purpose: To ensure buildings within the Curtis Road Interchange Overlay District are composed of durable materials and have a cohesive and compatible architectural design. 1.0 | No structure shall exceed seventy-five (75) feet in height. 1.1 | Where a structure exceeds a height of forty (40) feet, the building must be setback from any adjacent residentially zoned parcel by a minimum of 200 feet. 1.2 | Any exterior walls 125 feet in length or greater that face a public street, private street or outdoor gathering space must include a minimum of two (2) feet in variation of the vertical plane of wall at intervals of seventy-five (75) feet or less. At least 50% of the vertical surface area of each horizontal interval must be recessed, projected, or offset to meet this requirement. Intervals do not need to be equal in length. 1.3 | Each building shall have a primary entrance facing a public street, private street or outdoor gathering space. The facade containing the primary entrance shall be the primary facade of the building. The entrance shall connect to a public sidewalk, adjacent trail or outdoor gathering space in the most direct route, as determined by the Zoning Administrator, via an on-site pedestrian walkway. The pedestrian walkway shall meet the following requirements: a. The walkway must be a minimum of five (5) feet wide. Where the walkway is parallel to a parking row, it must be buffered by a minimum of three (3) feet from walkway edge to back of curb. The buffered area may be turf or landscape plantings. b. Where a pedestrian walkway crosses a drive aisle or vehicle lane, the pedestrian walkway material shall differ from the drive aisle material by composition, texture, or through the use of a differing color that is integral to the material. 1.4 | The primary entrance shall be covered by a shelter that is no less than three (3) feet in depth and five (5) feet in width. This shelter may be provided with a projection from the wall, an inset into the wall, or a combination of the two. 1.5 | Exterior building cladding must be of one or more of the following materials: true brick, genuine stone, precast concrete, glass, wood and rigid fiber cement product. Synthetic materials such as synthetic stucco (e.g. EIFS), vinyl siding, and pre-fabricated metals are permitted to comprise up to a maximum of twenty percent (20%) of a building's façade, excluding areas for glazing. 1.6 | Buildings two stories or more in height must have an expression line, such as a cornice, delineating the first floor. [image omitted; see the official code] A one story building shall have an expression line delineating the first floor or shall have an expression line located at the top of the building. [image omitted; see the official code] 1.7 | Where the principal use buildings share one lot and are less than twenty (20) feet from one another, the height of any cornice or expression line delineating the first floor shall be placed at the same height. [image omitted; see the official code] 1.8 | Awnings are permitted and shall be constructed of durable materials. Awnings may not be constructed of plastic nor be internally illuminated. 1.9 | A minimum of 35% of the area of the ground floor of the primary facade must consist of transparent glass. A minimum of 35% of the area of the ground floor of a second facade, selected by the applicant, must also consist of transparent glass. The Planning and Development Director may, at his or her discretion, approve a reduction of the minimum requirement for transparent glass of the ground floor of the second facade to no less than 17%. This waiver may only be approved if the applicant provides a site and building analysis demonstrating that utility, loading or other unsightly features either within or outside the building cannot be located in such a way to enable the required standard to be met. The calculation shall be measured from the ground to the top of the building, unless the building is two stories or greater. For buildings two stories or greater, a minimum of 17% of the area of each upper floor building facade must consist of transparent glass. No more than two facades are subject to this requirement. The calculation shall be measured from the expression line delineating the upper floor to the top of the building. Mirror reflective glass is prohibited. The percentage of glazing for each facade area subject to this requirement shall be provided on the building permit. 1.10 | Loading docks, overhead doors, and other vehicular service entries shall be screened in accordance with Sec. 37-559 and not be located on a façade facing the public right-of-way, outdoor gathering space or commons area. 1.11 | Each site must include space to adequately store all refuse, including recycling, until such time as the refuse is collected by a licensed waste hauler. 1.12 | Refuse storage areas integrated into a building shall not be accessed from the side of the building that faces a public right-of-way. 1.13 | Refuse storage areas separated from the building shall be consolidated and sized to adequately accommodate all refuse, including recycling, containers. Refuse storage areas shall be enclosed on all sides, with an opaque wall exceeding the height of the dumpster lid when opened. Refuse storage areas shall also include gates, or doors, that can be opened to access refuse and recycling containers. Refuse storage areas shall be clad in the same materials used on the exterior of the main building. 1.14 | Refuse storage areas shall include a horizontal cover or screen over the top of the enclosure. The horizontal screen or cover shall be integrated into the enclosure design. In lieu of a horizontal cover or screen, specialty dumpsters or waste receptacles may be used in place of traditional dumpsters or waste receptacles. The specialty dumpster(s) or waste receptacle(s) must include the following: a fully enclosed design with a disposal lid comprised of heavy-gauge metal that opens and closes via gravity when dumped and deposit doors comprised of heavy-gauge metal that are self-closing. The manufacturer's specifications of the specialty dumpster must be attached to the building permit. [image omitted; see the official code] 1.15 | Entities that offer food or other goods that are commonly consumed or used on site shall provide an outdoor wastebasket within ten feet of each public entrance, drive-through window, and outdoor seating area. Such uses may include, but are not limited to: mini-mart/service station, restaurant, and retail uses. 1.16 | Exterior mechanical equipment, including but not limited to, HVAC, utility meters or electrical cabinets must be screened from view using either built materials or landscaping from the approved plant material list. Exterior mechanical equipment cannot be located on a primary façade. PARKING AND ACCESS DESIGN Purpose: To ensure a safe an efficient traffic network that reduces conflicts between vehicles, pedestrians and bicyclists as well as to improve the aesthetic quality of the area. 2.0 | Parking areas, loading areas and access drives must be sited and designed in accordance with the standards outlined in Article VII of the Zoning Ordinance, as well as the requirements of this Table XI-F. 2.1 | Parking lots shall provide no less than 75% and no more than 125% of the minimum number of parking spaces that would otherwise be required in Article VII, Division 4. Residential uses are exempt from the maximum. The Planning and Development Director may approve an alternative number of parking spaces if an analysis of parking demand demonstrates justification for such alternative. 2.2 | When more than one principal use is established on a single lot, parking shall be shared in compliance with Sec. 37-357(c)(3). 2.3 | A minimum of 50% of the vehicular parking spaces shall be located to the side or rear of the principal building. The Planning and Development Director may approve an alternative parking design if an analysis of parking demand demonstrates justification for such alternative. 2.4 | For uses containing a drive-through, order boxes, menu boards, and pick-up or drop-off windows are prohibited in the front yard and on the front façade of the building. If the property is on a corner lot, the order box, menu board and pick-up or drop-off windows may be located on the buildings side façade or yard facing the street only when located at the rear two-thirds of the façade or yard. Menu boards shall contain landscaping around the menu board. LANDSCAPING AND SCREENING Purpose: To beautify the district with landscaping materials and to adequately screen parking, storage and utility areas. Landscaping and screening is also provided to protect the natural environment through the use of "best management practices", including shade trees, low impact stormwater management techniques and pollinator supporting plants. 3.0 | Landscaping and screening shall be in compliance with the standards set forth in Article X, as well as the requirements of this Table XI-F. 3.1 | Selection of plant materials shall be in conformance with the Approved Plant List, found in the Appendix of the Champaign Municipal Code. A minimum of 50% of species selected shall be those designated in the Approved Plant List as "pollinator supporting." 3.2 | Stormwater management plans shall demonstrate a Low Impact Design (LID) approach as a component of the overall stormwater management system for the site. LID includes stormwater management practices such as rain gardens, bio-retention areas, green roofs, and parking lot absorption islands. The site plan shall include best management practices designed to retain the 24-hour, 1-year storm with a discharge rate at or below the pre-development discharge rate. The stormwater management system is subject to approval by the City Engineer. 3.3 | Parking Lot Perimeter. In lieu of Section 37-555, parking lot perimeter setback, screening and landscaping shall meet the following standards: A. Parking lots shall be setback from the property line by a minimum of ten (10) feet and shall be screened with plantings. B. Parking lot perimeter screening shall have a minimum height of thirty-six (36) inches. Where the parking lot perimeter faces a public street, screening shall not exceed forty-two (42) inches in height. Screening provided by plantings shall obtain that height through natural growth within three years of the planting date. C. The Landscape Plan shall demonstrate a screening plan with plantings that will achieve a continuous hedge along 85% of the perimeter of the parking lot, where adjacent to a public or private street. The continuous hedge shall be achieved through natural growth within three years of the planting date. To achieve a continuous hedge, a minimum of one tree per twenty-five (25) feet and a minimum of five shrubs between each tree are required. At access points, screening may be reduced to allow for an adequate site triangle. D. Decorative fences or walls shall be allowed to provide up to fifty (50) percent of the required screening for the areas where they are used. Where decorative fencing is installed, one tree per twenty-five (25) feet is required. Required plantings shall be installed on the side of the decorative fence or wall that faces the street. Decorative fences shall be at least seventy-five (75) percent opaque and shall adhere to the following requirements: i. Materials. The decorative fence or wall shall consist of treated wood or naturally resistant wood such as redwood, cypress, or cedar, decorative split face concrete blocks or brick masonry; ii. Braces, supports or posts shall be located on the side of the property providing the screening; iii. In the front yard, fences may not exceed three feet in height, in the rear yard, fences may not exceed ten feet in height. Decorative fences or walls shall utilize the definitions and standards outlined in Division 3 - Yards and Setback Requirements. E. Parking lot design shall implement low-impact methods for stormwater management. This includes curb inlets coupled with parking lot edge zones that capture, filter and slow the flow of stormwater runoff. The final design of the parking lot edge zones, including the selected plantings, shall be approved by the City Engineer. F. The reference elevation for the base of the required screen shall be the surface of the parking area that is to be screened. 3.4 | Parking Lot Interior. In lieu of Section 37-556, Parking lot interior landscaping shall meet the following standards: A. Landscape islands shall be located at the ends of all rows of parking. For rows greater than 20 spaces, there shall be additional islands at a rate of one per fifteen (15) spaces. Fifteen spaces is along one side of a parking island. B. Landscape islands shall have an average minimum width of eight (8) feet wide from back of curb to back of curb and 150 square feet and shall be protected by a barrier curb. C. Each Landscape Island shall contain at least one tree approved for parking lot interiors from the approved plant list in the Appendix of the Champaign Municipal Code. A minimum of 75 percent of trees selected shall be designated as shade trees. There must be a minimum of two tree species selected. D. A continuous planting strip between parking rows may be substituted for the required landscaped islands. The planting strip shall be a minimum of eight (8) feet in width and shall be protected by a barrier curb with inlets allowing stormwater to drain into the planting strip. The planting strip shall be designed as a bioretention area that is depressed from the grade of the parking lot to capture and reduce the flow rate pollutant load of stormwater using Low Impact Design principles. A minimum of one tree for every six (6) parking spaces shall be planted in any such strip, with a tree at the end of each strip. E. Landscape Islands shall be designed to capture and reduce the flow rate of stormwater using Low Impact Design principles. A minimum of 75% of the total square footage of parking lot Landscape Islands shall be designed as bioretention areas and depressed from the grade of the parking lot. Inlets in the barrier curb shall be constructed to allow stormwater runoff to drain into the island. The final design of the Landscape Islands, including the selected plantings, shall be approved by the City Engineer. 3.5 | In parking lots with five or more parallel parking rows of 18 spaces or more, OR parking lots over 150 spaces, a continuous median island with pedestrian walkway must be provided running the length of the parking lot, connecting the primary public entrance to the building with the public sidewalk. The continuous median island shall adhere to the following standards: i. Total width shall be a minimum of thirteen (13) feet from back of curb to back of curb. The island shall contain a minimum eight (8) foot planting area with a five (5) foot pedestrian sidewalk. ii. A minimum of one tree for every six parking spaces shall be planted in the space, with a tree at each end of the island. iii. An access point from the drive aisle to the walkway must be provided a minimum of every twelve spaces. The access point must meet ADA standards for accessibility. iv. Where a pedestrian walkway crosses a drive aisle or vehicle lane, the pedestrian walkway material shall differ from the drive aisle material by composition, texture, or through the use of a differing color that is integral to the material. v. An additional median island shall be provided for each additional 200 spaces. In lieu of the additional median island, alternative pedestrian facilities that function to slow parking lot traffic and safely convey pedestrians from the main public entrance to the main public thoroughfare may be approved at the discretion of the Planning and Development Director. The continuous median island with pedestrian walkway may be substituted for the required landscaped islands described in 3.4 (above) for the parking rows impacted. 3.6 | Service and storage areas may not be located at the front of buildings. Service and storage areas shall be screened from any public or private street, or adjacent property with a 100 percent opaque masonry or wood fence, landscaping or any combination thereof which provides a minimum height of six (6) feet. 3.7 | Street trees along public streets and private access drives shall be provided in the public right-of-way at a ratio of at least one (1) tree per fifty (50) feet of frontage. 3.8 | The use of barbed and/or razor wire is prohibited. SIGNAGE Purpose: To allow for an appropriate amount of signage but yet not detract from high-quality aesthetics for development in the Curtis Road Interchange Overlay District. 4.0 | Signs in the Curtis Road Interchange Overlay District shall meet the requirements of Article VIII, with the following exceptions: (a) Freestanding signs. Freestanding signs shall only be monument-style signs and signs shall not be mounted on a pole. Freestanding signs for three or fewer businesses shall have a maximum height of six (6) feet. Freestanding signs for four or more businesses shall have a maximum height of twenty (20) feet. When located within the visibility triangle required by Section 37-195, the maximum height shall be three (3) feet. (b) Shopping center signage. Signage for shopping centers, as defined in Sec. 37-437(i), will follow the standards outlined in Article VIII, and shall be a maximum height of twenty (20) feet. (c) OASS and Interstate Highway Signs, as otherwise provided therein, are not permitted in the Curtis Road Interchange Overlay District. LIGHTING Purpose: Lighting standards are intended to provide adequate lighting for safety, security and convenience of users, yet reduce impacts of light pollution on occupants of adjacent properties and the environment. 5.0 | All private exterior lighting, including lighting on buildings as well as parking lot lights, shall at a minimum, meet the requirements set forth by the International Dark Sky Association and the Illuminating Engineering Society of North America in their 2011 Model Lighting Ordinance. 5.1 | Where street lights are required to be installed in the public right-of-way, the street lights used shall conform to those required in the University District as provided in the Champaign Municipal Code, except that the luminaire shall be dark sky compliant and the light source shall be LED. An alternative light source that has greater energy efficiency than an equivalent LED light source may be permitted with the approval of the City Engineer. The luminaire oriented toward the street shall be a cobra-head style, while the luminaire oriented toward the sidewalk shall conform to the amended University District standard. Light poles may have a maximum height of twenty-seven (27) feet along collector level streets and twelve (12) feet along local streets. 5.2 | Under-canopy lighting shall be fully recessed into the canopy to minimize light trespass. During business hours, canopy lighting shall not exceed five (5) footcandles. After business hours, canopy lighting shall not exceed one footcandle. Lighting level shall be measured at the property line. 5.3 | Parking lot lighting shall be mounted no higher than twenty-six (26) feet high and shall be fully shielded. Luminaires shall be certified as "Dark Sky Compliant" by the International Dark Sky Association. The light source shall be LED. An alternative light source that has greater energy efficiency than an equivalent LED light source may be permitted with the approval of the City Engineer. 5.4 | All development applications are required to include a photometric lighting plan. Photometric lighting plans shall show maximum average lighting levels per lot of five (5) footcandles for commercial and office uses. Multifamily residential uses shall have maximum average lighting levels per lot of one (1) footcandles. In addition, lighting plans shall show a maximum of 0.2 footcandles at the property line when property line is within or adjacent to the MF1 or MF2 zoning district or within 250 feet of any lot zoned SF-1 or SF-2, land outside of the municipal boundaries of the City of Champaign that is designated for low-density residential use in the generalized future land use map of the Comprehensive Plan, and future zoning of SF-1 or SF-2 as specified in a recorded annexation agreement. 5.5 | On lots which abut residentially zoned property or property that is designated by the Comprehensive Plan for future residential land use, all outdoor lighting fixtures must be set back a minimum of thirty (30) feet from the nearest residentially zoned property line. 5.6 | After 11:00 pm, parking lot lighting must be turned off or reduced by at least fifty percent (50%) of full operational level. For safety purposes, entities that provide services after 11:00 p.m. must provide parking lot lighting levels of not less than 0.2 footcandles as measured horizontally at the surface on which the light pole is mounted. The manufacturers specifications demonstrating that specified light fixtures include this capability shall be attached to the building permit.
(C.B. No. 2018-149, § 1(Exh. A), 9-18-18) (C.B. No. 2017-014, § 6(Att. F), 2-7-17; C.B. No. 2018-062, § 3(Exh. A), 5-1-18; C.B. No. 2018-149, § 1(Exh. A), 9-18-18)
Ask a question about Champaign law
Corpus searches the Champaign sections it holds and shows the ones that match, with their citations. Free, no sign-in.
