§ 9-251 — General standards
Code of Ordinances of the City of Champaign, Illinois (Codified through C.B. No. 2026-125, adopted August 18, 2026 (Supp. No. 81, Update 1)) · Champaign Code of Ordinances § 9-251
Corpus is an independent public-information project, not the official City of Champaign website. Stable reference: corpuslaw.us/code/b8f2f1a7-cb5a-4a9d-a004-33d5a29f1ca8
Sec. 9-251. - General standards.
In all special flood hazard areas, the following standards are required: (a) Anchoring. (1) All new construction and substantial improvements shall be anchored to prevent flotation, collapse, or lateral movement of the structure. (2) All mobile homes shall be anchored to resist flotation, collapse, or lateral movement by providing over-the-top and frame ties to ground anchors. Special requirements shall be that: (i) Over-the-top ties be provided at each of the four (4) corners of the mobile home, with two (2) additional ties per side at intermediate locations, with mobile homes less than fifty (50) feet long requiring one additional tie per side; (ii) Frame ties be provided at each corner of the home with five (5) additional ties per side at intermediate points, with mobile homes less than fifty (50) feet long requiring four (4) additional ties per side; (iii) All components of the anchoring system be capable of carrying a force of four thousand eight hundred (4,800) pounds; and (iv) Any additions to the mobile home be similarly anchored. (b) Construction materials and methods. All new construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage and using methods and practices that minimize flood damage. These requirements may be met by any of the following methods: (1) A structure may be constructed on a permanent landfill in accordance with the following: (i) The area to be filled shall be cleared of all standing trees, brush, down timber, trash, and other growth or objects unsuitable for use as foundation material. (ii) The fill shall be placed in layers no greater than one foot deep before compaction, and compacted to no less than ninety-five (95) percent of standard density. (iii) The surface of the fill shall be at or above the base flood elevation. The fill shall extend at least ten (10) feet beyond the foundation of the structure before sloping below the base flood elevation. (iv) The fill shall be protected against erosion and scour during flooding by vegetation cover, riprap, or bulkheading. If vegetative cover is used, the slopes shall be no steeper than 3 horizontal to 1 vertical. (v) The fill shall not adversely affect the flow of surface drainage from or onto neighboring properties. (vi) The Building Safety Manager shall maintain a record of the as-built elevation of the lowest floor of the structure and certification to subsections 9-251(b)(1) through (3), as provided by a registered architect or engineer. (2) A structure may be elevated in accordance with the following: (i) The structure or improvements shall be elevated on stilts, piles, walls, crawl space, or other foundation that is permanently open to floodwaters and not subject to damage by hydrostatic pressures. (ii) The foundation and supporting member shall be anchored, shaped and aligned so as to minimize exposure to known hydrodynamic forces such as currents, waves, and floating debris. (iii) All areas below the base flood elevation shall be constructed of materials resistant to flood damage. The bottom of the joists of the lowest flood and all utility meters shall be located at or above the base flood elevation. (iv) Building Safety Manager shall maintain a record of the as-built elevation of the lowest floor of the structure, as provided by a registered architect or engineer. (v) No area below the base flood elevation shall be used for storage of items or materials subject to flood damage unless such items or materials are declared "property not covered" by a standard flood insurance policy of the National Flood Insurance Program. (vi) Any future alteration of the area below the base flood elevation that violates the requirements of this section shall be deemed a violation of this article. (3) A nonresidential building may be floodproofed in accordance with the following: (i) A registered architect or engineer shall certify that the building has been designed so that below the base flood elevation, the structure and attendant utility facilities are watertight and capable of resisting the effects of the base flood. The building design shall take into account flood velocities, duration, rate of rise, hydrostatic and hydrodynamic forces, the effects of buoyancy, and impacts from debris or ice. (ii) Floodproofing measures shall be operable without human intervention and without an outside source of electricity. (iii) The Building Safety Manager shall maintain the certificate of the registered architect or engineer and a record of the as-built elevation to which the building was floodproofed. (c) Utilities. (1) All new and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system. (2) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and discharge from the systems into floodwaters. (3) On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding. (d) Subdivision and planned unit development proposals within special flood hazard areas. (1) All subdivision and planned unit development proposals shall be consistent with the need to minimize flood damage by complying with the requirements of this article. (2) All subdivision and planned unit development proposals shall have public utilities and facilities such as sewer, gas, electrical, and water systems located and constructed to minimize flood damage. (3) All subdivisions and planned unit development shall have adequate drainage provided to reduce exposure to flood damage. (4) Plats or plans for new subdivisions and planned unit developments shall display the following flood data: (i) Boundary of the special flood hazard area; (ii) Boundary of the floodway, if shown on available flood boundary-floodway map and flood insurance rate maps, City of Champaign; (iii) Easements or lands dedicated to the public for channel maintenance purposes; and (iv) The base flood elevation for each building site. (e) Other development requirements. (1) The City Council shall take into account flood hazards, to the extent that they are known, in all official actions related to land management, use and development, including, but not limited to, annexation agreements, plats both inside and outside the City limits, capital improvements programming, and acquisition. (2) Plans for the development activities to be undertaken by the City in the special flood hazard areas shall be reviewed by the City Engineer to ensure that they comply with this article. Except as exempted by law, no local government shall be relieved of compliance with this article.
(C.B. No. 81-1, § 5.1, 1-6-81; C.B. No. 2026-125, § 1(Exh. 1), 8-18-26)
Ask a question about Champaign law
Corpus searches the Champaign sections it holds and shows the ones that match, with their citations. Free, no sign-in.
