Sec. 9-252. - Specific standards.

In all special flood hazard areas where base flood elevation data have been provided as set forth in section 9-222, Basis for establishing special flood hazard areas, or in section 9-235, Use of Base flood elevation data, the following standards are required: (a) Residential construction. New construction and substantial improvement of any residential structure shall have the lowest floor, including basement, elevated to or above the base flood elevation with the use of fill or other methods such as columns or piles. (b) Nonresidential construction. New construction and substantial improvement of any commercial, industrial or other nonresidential structure shall either have the lowest floor, including basement, elevated to the level of the base flood elevation or, together with attendant utility and sanitary facilities, shall: (1) Be floodproofed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water; (2) Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyance; and (3) Be certified by a registered architect or engineer that the standards of this subsection are satisfied. Such certifications shall be provided to the Building Safety Manager as required in Division 2 of this article. (c) Mobile homes. (1) Mobile homes shall be anchored in accordance with subsection 9-251(a). (2) For new mobile home parks and mobile home subdivisions, expansions to existing mobile home parks and mobile home subdivisions, existing mobile home parks and mobile home subdivisions where the repair, reconstruction or improvement of the streets, utilities and pads equals or exceeds fifty (50) percent of the value of the streets, utilities and pads before the repair, reconstruction or improvement has commenced, and for mobile homes not placed in a mobile home park or mobile home subdivision, the City Engineer or the Building Safety Manager shall require that: (i) Stands or lots as elevated on compacted fill or on pilings so that the lowest floor of the mobile home will be at or above the base flood level; and (ii) Adequate surface drainage and access for a hauler are provided. (3) In the instance of elevation on pilings that: (i) Lots are large enough to permit steps; (ii) Piling foundations are placed in stable soil no more than ten (10) feet apart; and (iii) Reinforcement is provided for pilings more than six (6) feet above the ground level. (4) No mobile home shall be placed in a floodway, except in an existing mobile home park or an existing mobile home subdivision.

(C.B. No. 81-1, § 5.2-3, 1-6-81; C.B. No. 2026-125, § 1(Exh. 1), 8-18-26)

Ask a question about Champaign law

Corpus searches the Champaign sections it holds and shows the ones that match, with their citations. Free, no sign-in.