§ 18-28-801.13 — Cleanouts
Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 18-28-801.13
Corpus is an independent public-information project, not the official City of Chicago website. Stable reference: corpuslaw.us/code/a4237a29-0a91-44a7-b674-be6315db6267
18-28-801.13 Cleanouts.
Masonry chimney flues shall be equipped with a cleanout opening that has a minimum height of 6 inches (152 mm). The upper edge of the opening shall be located not less than 6 inches (152 mm) below the lowest chimney inlet opening. The cleanout shall be provided with a tight-fitting, noncombustible cover. Exceptions: Cleanouts shall not be required for chimney flues that serve masonry fireplaces if the flues are provided with access through the fireplace opening.
Ask a question about Chicago law
Corpus searches the Chicago sections it holds and shows the ones that match, with their citations. Free, no sign-in.
