18-29-1102.5 Subsoil drain pipe.

Subsoil drains shall be open-jointed, horizontally split or perforated pipe conforming to one of the standards listed in Table 18-29-1102.5, except corrugated pipe is not allowed. Table 18-29-1102.5 Subsoil Drain Pipe Material | Standard Cast-iron pipe | ASTM A74; ASTM A888; CISPI 301 Polyethylene (PE) plastic pipe | ASTM F405; ASTM F667; CSA B182.1; CSA B182.6; CSA B182.8 Polyvinyl chloride (PVC) plastic pipe (Type Sewer Pipe, PS25, SDR35, PS50 or PS100) | ASTM D 2729; ASTM D3034; ASTM F891; CSA B182.2; CSA B182.4 Stainless steel drainage systems, Type 316L | ASME A112.3.1 Vitrified clay pipe | ASTM C4; ASTM C700 (Amend Coun. J. 7-29-15, p. 3537, § 4; Amend Coun. J. 10-14-21, p. 37722, Art. XI, § 3)