§ 18-29-1102.5 — Subsoil drain pipe
Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 18-29-1102.5
Corpus is an independent public-information project, not the official City of Chicago website. Stable reference: corpuslaw.us/code/d2f0f5d3-57d8-4efb-a44c-38e5e673c329
18-29-1102.5 Subsoil drain pipe.
Subsoil drains shall be open-jointed, horizontally split or perforated pipe conforming to one of the standards listed in Table 18-29-1102.5, except corrugated pipe is not allowed. Table 18-29-1102.5 Subsoil Drain Pipe Material | Standard Cast-iron pipe | ASTM A74; ASTM A888; CISPI 301 Polyethylene (PE) plastic pipe | ASTM F405; ASTM F667; CSA B182.1; CSA B182.6; CSA B182.8 Polyvinyl chloride (PVC) plastic pipe (Type Sewer Pipe, PS25, SDR35, PS50 or PS100) | ASTM D 2729; ASTM D3034; ASTM F891; CSA B182.2; CSA B182.4 Stainless steel drainage systems, Type 316L | ASME A112.3.1 Vitrified clay pipe | ASTM C4; ASTM C700 (Amend Coun. J. 7-29-15, p. 3537, § 4; Amend Coun. J. 10-14-21, p. 37722, Art. XI, § 3)
Ask a question about Chicago law
Corpus searches the Chicago sections it holds and shows the ones that match, with their citations. Free, no sign-in.
