18-29-1105.1 Strainers.
Roof drains shall have strainers extending not less than 4 inches (100 mm) above the surface of the roof immediately adjacent to the roof drain. Strainers shall have an available inlet area, above roof level, of not less than one and one-half times the area of the conduct or leader to which the drain is connected. All downspouts from gravel roofs shall be fitted with serviceable devices to screen out loose gravel.