For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18-29-1106.2 — Vertical conductors and leaders

Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 18-29-1106.2

Corpus is an independent public-information project, not the official City of Chicago website. Stable reference: corpuslaw.us/code/b9b1a9ab-8e02-4169-aeef-7bdd33e800a0

18-29-1106.2 Vertical conductors and leaders.

No downspout shall be of smaller size than shown in Table 18-29-1106.2, based on the maximum horizontal projected roof area drained. Downspouts that are offset at 90 degrees shall be sized as a horizontal storm drain and shall be full size to the storm drain or sewer or combined drain or sewer. The above sizes of downspouts are based on the diameter of circular downspouts and other shapes shall have equivalent cross-sectional area. Table 18-29-1106.2 Downspouts Diameter of Downspout (inches) | Max. Horizontal Projected Roof Area (square feet) Diameter of Downspout (inches) | Max. Horizontal Projected Roof Area (square feet) 2 | 720 2 1/2 | 1,300 3 | 2,150 4 | 4,600 5 | 8,300 6 | 13,000 8 | 29,000 10 | 52,000 12 | 83,000 13 | 155,000

Ask a question about Chicago law

Corpus searches the Chicago sections it holds and shows the ones that match, with their citations. Free, no sign-in.