§ 18-29-705.18.3 — Cast-iron pipe to galvanized steel or brass pipe
Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 18-29-705.18.3
Corpus is an independent public-information project, not the official City of Chicago website. Stable reference: corpuslaw.us/code/dd68a2a2-ccc5-4f70-a7f4-75dd00a2744d
18-29-705.18.3 Cast-iron pipe to galvanized steel or brass pipe.
Joints between cast-iron pipe and galvanized steel or brass pipe shall be made by either caulked or threaded joints or with an approved adapter fitting. (Amend Coun. J. 10-14-21, p. 37722, Art. VII, § 5)
Ask a question about Chicago law
Corpus searches the Chicago sections it holds and shows the ones that match, with their citations. Free, no sign-in.
