Chapter 7 — Sanitary Drainage (18-29-701 et seq.)
Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026), Chicago, IL · 155 sections. Independent public-information project, not the official City of Chicago website.
- § 18-29-701.1 — Scope
- § 18-29-701.2 — Sewer required
- § 18-29-701.3 — Separate building sewer connection
- § 18-29-701.4 — Sewage treatment
- § 18-29-701.5 — Damage to drainage system or public sewer
- § 18-29-701.6 — Tests
- § 18-29-701.7 — Connections
- § 18-29-701.8 — Notification of wrecking buildings and sealing or abandoning sewer facilities
- § 18-29-702.1 — Above-ground sanitary drainage and vent pipe
- § 18-29-702.1.1 — Mixed-occupancy buildings
- § 18-29-702.2 — Underground building sanitary drainage and vent pipe
- § 18-29-702.3 — Building sewer pipe
- § 18-29-702.4 — Fittings
- § 18-29-702.5 — Temperature rating
- § 18-29-702.6 — Chemical waste system
- § 18-29-702.8 — Safe pans
- § 18-29-702.8.1 — Material
- § 18-29-702.8.2 — Construction
- § 18-29-703.1 — Building sewers, building drains or drainage systems installed near the water pipes and water supply system
- § 18-29-703.2 — Drainage pipe in filled ground
- § 18-29-703.3 — Sanitary and storm sewers
- § 18-29-703.3.1 — Combined sewers
- § 18-29-703.4 — Existing building sewers and drains
- § 18-29-703.4.1 — Inspection of existing underground building sewers for drain and reuse
- § 18-29-704.1 — Slope of horizontal drainage piping
- § 18-29-704.2 — Change in size
- § 18-29-704.3 — Connections to offsets and bases of stacks
- § 18-29-704.4 — Future fixtures
- § 18-29-705.1 — General
- § 18-29-705.5 — Cast iron
- § 18-29-705.5.1 — Caulked joints
- § 18-29-705.5.2 — Compression gasket joints
- § 18-29-705.5.3 — Mechanical joint coupling
- § 18-29-705.6 — Concrete joints
- § 18-29-705.7 — Copper pipe
- § 18-29-705.7.1 — Brazed joints
- § 18-29-705.7.2 — Mechanical joints
- § 18-29-705.7.3 — Soldered joints
- § 18-29-705.7.4 — Threaded joints
- § 18-29-705.7.5 — Welded joints
- § 18-29-705.8 — Copper tubing
- § 18-29-705.8.1 — Brazed joints
- § 18-29-705.8.2 — Mechanical joints
- § 18-29-705.8.3 — Soldered joints
- § 18-29-705.9 — Borosilicate glass joints
- § 18-29-705.9.1 — Caulked joints
- § 18-29-705.10 — Steel
- § 18-29-705.10.1 — Threaded joints
- § 18-29-705.10.2 — Mechanical joints
- § 18-29-705.12 — PVC plastic
- § 18-29-705.12.1 — Mechanical joints
- § 18-29-705.12.2 — Solvent cementing
- § 18-29-705.12.3 — Threaded joints
- § 18-29-705.13 — Vitrified clay
- § 18-29-705.14 — Polyethylene plastic
- § 18-29-705.14.1 — Heat-fusion joints
- § 18-29-705.14.2 — Mechanical joints
- § 18-29-705.15 — Polyolefin plastic
- § 18-29-705.15.1 — Heat-fusion joints
- § 18-29-705.15.2 — Mechanical and compression sleeve joints
- § 18-29-705.16 — Polyvinylidene fluoride plastic
- § 18-29-705.16.1 — Heat-fusion joints
- § 18-29-705.16.2 — Mechanical and compression sleeve joints
- § 18-29-705.18 — Joints between different materials
- § 18-29-705.18.1 — Copper pipe or tubing to cast-iron hub pipe
- § 18-29-705.18.2 — Copper or copper-alloy pipe or tubing to galvanized steel pipe
- § 18-29-705.18.3 — Cast-iron pipe to galvanized steel or brass pipe
- § 18-29-705.18.4 — Plastic pipe or tubing to other piping material
- § 18-29-705.18.6 — Borosilicate glass to other materials
- § 18-29-705.18.7 — Stainless steel drainage systems to other materials
- § 18-29-705.19 — Drainage slip joints
- § 18-29-705.20 — Caulking ferrules
- § 18-29-705.22 — Stainless steel drainage systems
- § 18-29-706.1 — Connections and changes in direction
- § 18-29-706.2 — Obstructions
- § 18-29-706.3 — Installation of fittings
- § 18-29-707.1 — Prohibited joints
- § 18-29-708.1 — Scope
- § 18-29-708.2 — Cleanout plugs
- § 18-29-708.3 — Where required
- § 18-29-708.3.1 — Horizontal drains within buildings
- § 18-29-708.3.2 — Building sewers
- § 18-29-708.3.3 — Changes of direction
- § 18-29-708.3.4 — Base of stack
- § 18-29-708.3.5 — Building drain and building sewer junction
- § 18-29-708.3.6 — Manholes
- § 18-29-708.4 — Concealed piping
- § 18-29-708.5 — Opening direction
- § 18-29-708.6 — Prohibited installation
- § 18-29-708.7 — Minimum size
- § 18-29-708.8 — Pipes 8 inches and larger
- § 18-29-708.9 — Clearances
- § 18-29-708.10 — Access
- § 18-29-709.1 — Values for fixtures
- § 18-29-709.2 — Fixtures not listed in Table 18-29-709.1
- § 18-29-709.3 — Conversion of gpm flow to dfu values
- § 18-29-709.5 — Values for indirect waste receptor
- § 18-29-709.5.1 — Clear-water waste receptors
- § 18-29-710.1 — Maximum fixture unit load
- § 18-29-710.1.1 — Sizing building drains and building sewers for combined sanitary and storm drainage
- § 18-29-710.1.2 — Minimum size
- § 18-29-710.1.3 — Horizontal stack offsets
- § 18-29-710.1.4 — Vertical stack offsets
- § 18-29-710.2 — Future fixtures
- § 18-29-710.3 — Underground drainage piping
- § 18-29-711.1 — Horizontal branch connections above or below vertical stack offsets
- § 18-29-711.1.1 — Omission of vents for vertical stack offsets
- § 18-29-711.2 — Horizontal branch connections to horizontal stack offsets
- § 18-29-711.3 — Horizontal stack offsets
- § 18-29-711.3.1 — Omission of vents for horizontal stack offsets
- § 18-29-711.3.2 — Suds pressure zones
- § 18-29-711.3.2.1 — Height
- § 18-29-711.3.2.2 — Upstream
- § 18-29-711.3.2.3 — Downstream
- § 18-29-711.4 — Offsets below lowest branch
- § 18-29-712.1 — Building drains below sewer
- § 18-29-712.2 — Check and gate valve required
- § 18-29-712.3 — Sump design
- § 18-29-712.3.1 — Sump pump
- § 18-29-712.3.2 — Sump pit
- § 18-29-712.3.3 — Discharge piping
- § 18-29-712.3.4 — Maximum effluent level
- § 18-29-712.3.5 — Ejector connection to the drainage system
- § 18-29-712.4 — Sewage pumps and sewage ejectors
- § 18-29-712.4.1 — Capacity
- § 18-29-712.4.2 — Duplex equipment required
- § 18-29-713.1 — Scope
- § 18-29-713.2 — Bedpan washers and clinical sinks
- § 18-29-713.3 — Indirect waste
- § 18-29-713.4 — Vacuum system station
- § 18-29-713.5 — Bottle system
- § 18-29-713.6 — Central disposal system equipment
- § 18-29-713.7 — Central vacuum or disposal systems
- § 18-29-713.7.1 — Piping
- § 18-29-713.7.2 — Velocity
- § 18-29-713.8 — Vent connections prohibited
- § 18-29-713.9 — Local vents and stacks for bedpan washers
- § 18-29-713.9.1 — Multiple installations
- § 18-29-713.9.2 — Trap required
- § 18-29-713.9.3 — Trap seal maintenance
- § 18-29-713.10 — Sterilizer vents and stacks
- § 18-29-713.10.1 — Drainage
- § 18-29-713.11 — Sterilizer vent stack sizes
- § 18-29-713.11.1 — Bedpan steamers
- § 18-29-713.11.2 — Boiling-type sterilizers
- § 18-29-713.11.3 — Pressure sterilizers
- § 18-29-713.11.4 — Pressure instrument washer sterilizer sizes
- § 18-29-715.1 — Sewage backflow
- § 18-29-715.2 — Fixture branches
- § 18-29-715.3 — Material
- § 18-29-715.4 — Seal
- § 18-29-715.5 — Diameter
- § 18-29-715.6 — Location
- § 18-29-716.1 — Flood control devices
- § 18-29-716.2 — Flood control systems