§ 18-29-708.7 — Minimum size
Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 18-29-708.7
Corpus is an independent public-information project, not the official City of Chicago website. Stable reference: corpuslaw.us/code/d39429ae-f7e2-4208-b4fa-6e464d3bb970
18-29-708.7 Minimum size.
Cleanouts shall be the same nominal size as the pipe they serve up to 4 inches (100 mm). For pipes larger than 4 inches (100 mm) nominal size, the minimum size of the cleanout shall be 4 inches (100 mm). Exception: "P" trap connections with slip joints or ground joint connections, or stack cleanouts that are no more than one pipe diameter smaller than the drain served, shall be approved.
Ask a question about Chicago law
Corpus searches the Chicago sections it holds and shows the ones that match, with their citations. Free, no sign-in.
