For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18-29-712.2 — Check and gate valve required

Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 18-29-712.2

Corpus is an independent public-information project, not the official City of Chicago website. Stable reference: corpuslaw.us/code/d8ad3bd2-19c4-41c4-a6f4-69f6c8f6653c

18-29-712.2 Check and gate valve required.

A gate valve located on the discharge side of the check valve shall be installed in the pump or ejector discharge piping between the pump or ejector and the gravity drainage system. Access shall be provided to such valves. Such valves shall be located above the sump cover required by Section 18-29-712.1 or, when the discharge pipe from the ejector is below grade, the valves shall be accessibly located outside the sump below grade in an access pit with a removable access cover. (Amend Coun. J. 6-17-26, p. 45214, Art. IV, § 62)

Ask a question about Chicago law

Corpus searches the Chicago sections it holds and shows the ones that match, with their citations. Free, no sign-in.