For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18.28.020 — Sanitary and storm utilities

Code of Ordinances of the City of Elgin, Illinois (Codified through Ordinance No. G18-26, enacted May 27, 2026 (Supp. No. 8)) · Elgin Code of Ordinances § 18.28.020

Corpus is an independent public-information project, not the official City of Elgin website. Stable reference: corpuslaw.us/code/288880ca-cce2-4524-8f6a-a8a289021166

18.28.020. - Sanitary and storm utilities.

A. Sanitary sewer service lines, including sewer stub terminals at the property line of each lot or each potential building location, shall be installed to serve all properties except where private septic systems are permitted. Sanitary sewer service lines shall be connected to a public sanitary sewage collection system which shall be connected to a public sanitary wastewater treatment facility. All sanitary sewer services shall have a cleanout located on the service one (1) foot inside the property line. B. Interim septic systems may be allowed when sanitary sewer service is not available and shall be subject to the following requirements: 1. The property shall be annexed to the Fox River water reclamation district or, if not contiguous to the district, a restrictive annexation to the district when contiguity is established and requiring disconnection from the temporary septic system and connection to the sanitary sewer system within six (6) months of the availability of sewer service. Annexation and connection fees shall be payable consistent with standard district requirements. The owner of the property shall cause a copy of such restriction to be filed in the office of the recorder of deeds. 2. No further municipal action, including, but not limited to, approval of a performance bond, issuance of a building permit, or approval of engineering plans and specifications shall be taken until the required covenant has been recorded. 3. All service and lateral sewer line extensions shall be installed for future connection when feasible and as determined by the city engineer. 4. The developer shall submit required percolation tests and septic system design prepared and sealed by a professional engineer registered in the state, prior to the issuance of any building permit. C. A stormwater drainage system meeting requirements of title 21 shall be installed throughout the entire subdivision to control water from all inlets and shall be provided with an adequate outfall. The stormwater drainage system shall be separate and independent of the sanitary sewer system. The stormwater drainage system shall include a major drainage system designed to safely convey the one (1) percent (one hundred (100) year) event to detention facilities and then to a receiving conveyance. The stormwater drainage system shall consider upstream runoff and shall provide facilities to pass upstream runoff. D. Where a storm sewer system with a greater capacity than is necessary to serve the development is required by the city engineer, the developer shall pay for the installation of the entire system. The developer shall be eligible for future reimbursement for oversizing, the amount of which shall be determined jointly by the developer and the city engineer and approved by the city council. The city council shall subsequently pass an ordinance which will list the amount each property upstream of and contributing to the sewer system and not under the control of the developer shall pay for the oversizing. E. Sanitary and storm sewers shall consist of materials approved by the city engineer and Fox River water reclamation district. Sanitary and storm sewer systems shall be watertight in all aspects. The city engineer may permit the use of drywell or perforated pipe systems. F. Connections to a sanitary sewer shall be made with manufactured wyes and tees. Cutting the sewer main to install a service is prohibited. Connections to a storm sewer shall only be made at a catch basin, manhole or approved structure. Direct connection to storm sewer pipe is prohibited. G. All sanitary and storm sewer mains (does not include laterals) to be publicly owned and maintained shall be inspected one (1) year following the system's completion via videotape or an approved electronic recording system. Said inspection must be provided to the city engineer for approval prior to acceptance of the sewers for public maintenance. H. Each lot within a plotted subdivision shall be given access to a storm sewer structure for the purpose of connecting a sump pump. Each residential building within a subdivision that includes a sump pump shall be provided with a connection to a storm sewer structure and a six (6) inch diameter drain tile from the structure to the building. The owner of the property shall be responsible for the maintenance of the six (6) inch diameter drain tile and the connection to the storm sewer structure. I. All sanitary sewers and storm sewers shall conform to titles 14 and 21.

(Ord. No. G37-13, 2013; Ord. No. G35-00, § 1, 2000; Code 1976, § 18.28.020)

Ask a question about Elgin law

Corpus searches the Elgin sections it holds and shows the ones that match, with their citations. Free, no sign-in.