18.28.030. - Water supply.

A. Water distribution facilities shall be installed to serve all properties within the development. B. The water distribution system shall be designed to be compatible with the overall distribution network of the city. Dead-end mains shall be avoided wherever possible as determined by the city engineer. C. Where a water system is required by the city engineer with a capacity which is greater than that necessary to serve the proposed development, the city shall pay the cost of oversizing for the additional capacity. D. Where it is necessary to extend a water distribution facility outside the boundaries of the proposed development, the required extension may be eligible for reimbursement as determined by the city engineer and approved by the city council. E. The minimum size required for water distribution mains shall be eight (8) inches. In water main replacement projects, size of feeder main will be taken into account for sizing purposes. F. Water taps shall be made, bringing the water service to the property line of each lot or each potential building location, to serve all properties within the development prior to the completion of street surfacing. G. One (1) inch water taps shall be provided for all one (1) family and two (2) family zoned lots, and eight (8) inch water taps shall be provided for all lots or potential building locations within developments zoned for manufacturing. H. The size of water taps within multifamily and commercial developments shall be determined by the city engineer. I. Except in planned unit developments, the water taps will be made by the department of public works and engineering and the developer shall reimburse the city according to the fees established by the city council. J. Water mains shall be looped. Water main shall not pass through side yards or rear yards. K. Valves shall be spaced to have a maximum shutdown of twenty (20) homes. L. Maximum fire hydrant spacing is three hundred (300) feet.

(Ord. No. G37-13, 2013; Ord. No. G35-00, § 1, 2000; Code 1976, § 18.28.030)

Ask a question about Elgin law

Corpus searches the Elgin sections it holds and shows the ones that match, with their citations. Free, no sign-in.