4-4-2. - AMENDMENTS.
2021 International Fire Code: The 2021 International Fire Code adopted hereby shall read as follows with respect to the indicated Sections. 101.1: Title: These regulations shall be known as the Fire Code of the City of Evanston, hereinafter referred to as "this Code." 111.1: Appeals: Any person, firm or corporation affected by any decision, interpretation or order of the Fire Official made under any provision of these Codes or the standards adopted herein, may appeal such decision, interpretation, or order to the Fire Chief by filing a written notice of such intent to the office of the Fire Chief within fifteen (15) days after the day the decision, interpretation, or order was served. For purposes of this Section, a decision, interpretation, or order is served upon delivery, in the case of personal delivery, and in the case of mailing, five (5) days after deposit in the U.S. mail with first-class postage prepaid. The Fire Chief, or his/her designee, shall convene a hearing upon such appeal within ten (10) days of receipt thereof and may, when no immediate hazard exists, continue such hearing from time to time for cause. The Fire Chief shall establish reasonable rules for such hearings and shall make a record of proceedings. The rules shall be on file with the Fire Chief's office. The decision of the Fire Chief shall be deemed final as to the order or interpretation appealed from. The decision shall be in writing and shall be issued within two (2) business days of its rendering. Where there are practical difficulties in the implementation of the strict provisions of these Codes, the Fire Chief may modify such provision provided that such modification shall effect substantial conformance with the provisions hereof, provide for the public safety. A person is "affected" for the purposes of an appeal pursuant to this Section when the person has a material or definitive interest in the decision, interpretation, or order of the official. An application for appeal shall be based on a claim that the true intent of a Code adopted by the City or the rules legally adopted thereunder, have been incorrectly interpreted, or the provision of these Codes are adequately satisfied by other means. 307.4.3 Fire Pit Regulations: The use of fire pits will be allowed provided the following regulations are complied with: 1) For clarity, a fire pit includes a permanent below ground fire pit, a permanent grade level outdoor fireplace or a portable outdoor fireplace, all intended to contain and control outdoor wood fires. 2) Portable fire pits, constructed of steel, brick, or masonry, shall be used in accordance with the manufacturers specifications and safety guidelines and must be placed upon a non-combustible surface. 3) Only natural seasoned firewood or commercial logs may be burned. 4) The fires in fire pits shall be kept manageable. 5) The use of the fire pit must be attended and supervised by a competent adult property owner until the fire has been completely extinguished. A legal resident/tenant of a property may use a fire pit in accordance to this ordinance as long as the property owner or assigned management company grants written permission to the legal resident/tenant. The use of the fire pit must be attended and supervised by the legal resident/tenant until the fire has been completely extinguished. 6) A portable ten pound (10 lb.) ABC type fire extinguisher or other approved extinguishing equipment, such as a garden hose, bucket of sand, or dirt, must be readily available. 7) The use of a fire pit which creates a hazardous or objectionable condition shall be prohibited. The code official is authorized to order the extinguishment of a fire in a fire pit creating a hazardous or objectionable condition. 8) The use of the fire pit shall not be located within ten feet (10') of a structure or any combustible material. In no case shall the appliance be located directly under overhead combustible construction. 9) The use of the fire pit shall not cause any building fire alarm system to activate. 10) Guidelines when using fire pit shall include common sense, respect for neighbors and neighborhoods. 308.1.4: Open-Flame Cooking Grills: Barbecue grills shall not be used on any stairs or porches that serve as a means of egress. The use of barbecues will be allowed on balconies or at ground level provided the following regulations are complied with: 1) The use of a cooking grill which creates or adds to a hazardous or objectionable situation shall be prohibited. 2) Read the owner's manual for safety guidelines. 3) The use of the barbecue shall not cause the building's fire alarm system to activate. 4) A portable fire extinguisher shall be located in close proximity to the barbecue, but not affixed to the grill. The fire extinguisher shall be at least a 10 pound ABC type extinguisher. 5) Extreme caution shall be exercised when lighting the barbecue to prevent flames from elevating to an excessive height. 6) Hot ashes or cinders shall be deposited into noncombustible receptacles free of all combustible material and away from combustible construction. 404.4.1: Emergency guide: Fire safety evacuation plans in accordance with Section 404.2.1 shall be provided to each living unit on an annual basis. Living units include apartments, condominiums, dormitories, hotels, and any other type of residential or commercial living unit. 505.1.1: Address on Rear and Side Doors: Signage with the address, including the name of the street and business name or building name, shall be installed at all other entrance and exit doors. The sign shall be installed at a height of approximately five feet (5') above the standing surface. The sign shall be installed immediately to the latch side of the door so it is visible with the door in the open or closed position. All other installation locations shall be approved by the Fire Official. 505.3: Truss (Wood) Construction Signage: Identification signage as designated by the Fire Official shall be installed by the property owner on all structures in which the roof is of a truss construction design. The signage shall be approved by the Fire Official and installed so that it is visible from the street for the Fire Department use. 508.1.1.1: Fire Command Center: All fire command centers shall be equipped with a five (5)-button combination keypad for entry into the room or other entry device approved by the Fire Official. 509.1.2: Room Identification: Signage shall be placed at all doors identifying the room. The signage shall be installed at a height of approximately five feet (5') above the standing surface. The signage shall be installed immediately to the latch side of the door so it is visible with the door in the open or closed position. 603.2.3: Electrical Equipment: The Fire Official may require remote power disconnects for specialized electrical equipment such as solar panels, wind turbines, etc. 604.3.1: Manual Transfer: Standby power shall be manually transferable to all elevators in each bank. This transfer switch shall be located in the fire command room or location designated by the Fire Official. 901.7: Systems Out of Service: Any required fire protection/detection system placed out of service for more than six (6) hours in a day and/or for a cumulative total of twenty (20) hours a week shall require the approval of the Fire Official or his designee. Any fire protection/detection system placed out of service for periods equal to or greater than those stated without the approval of the Fire Official, will be subject to the following fines: ■ First warning: No charge ■ Second warning: $200.00 ■ Third warning: $300.00 ■ Fourth and subsequent warnings: $500.00 903.2: Where Required: Approved automatic sprinkler systems in new buildings and structures shall be provided in the locations described in Sections 903.2.1 through 903.2.12. In any Group, where the condition requiring an automatic sprinkler system states a fire area greater than 5,000 square feet, that square footage shall be changed to 5,000. All other conditions for the Group shall apply. The building area shall be defined in accordance with Section 202 and include each story. Reference the 2021 International Residential Code Section R313 Automatic Fire Sprinkler Systems as amended for provisions for townhouses and one- and two-family dwellings including those with accessory dwelling units. 903.3.1: Standards: Sprinkler systems shall be designed and installed in accordance with Section 903.3.1.1, Section 903.3.1.2, or Section 903.3.1.3 and other chapters of this Code, as applicable. A minimum of five (5) psi safety factor in the fire protection system hydraulic calculations shall be provided for all systems, except in one- and two-family dwellings. The system demand shall be five (5) psi below the seasonal low-water test supply. Sprinklers shall be required in all clothes closets, linen closets, pantries, and bathrooms, regardless of size, except in one- and two-family dwellings. 903.3.7.1: Number of Fire Department Connections: The Fire Official shall determine the number of Fire Department connections appropriate for the building. 903.3.7.2 Access to Fire Department Connections: Any Fire Department connection located behind or within landscaping or vegetation shall have a concrete path from the sidewalk or closest public way to the connection. A concrete pad with minimum dimensions of forty-eight inch (48") x forty-eight inch (48") shall also be provided at the Fire Department connection. 903.3.7.3: Type of Fire Department Connections: Unless otherwise approved by the Fire Code Official, a five (5) inch Storz type connection with a thirty (30) degree down turn shall be required. The fire department connection shall be installed between twenty-four (24) inches and forty-two (42) inches above the standing surface. 903.3.7.4: Fire Department Connection Locator: Provide a white strobe light above all Fire Department connections to flash upon activation of the fire alarm system. All strobes shall be installed at a height that will make it visible from the street. Exception: Existing systems, unless the system is altered, modified, or upgraded. 903.4.3.1: Sprinkler Control Valves: Approved supervised indicating control valves shall be provided at the point of connection to the riser on each floor in all buildings. Control valves shall also be provided for each individual unit (commercial, residential, or business) where the units share a common water supply and have individual entrances. 904.3.5.1 Alternate Systems Monitoring: All new alternate automatic fire extinguishing systems shall be monitored by a fire alarm signaling system in accordance with NFPA 72 remote or central supervision station. 905.3.1: Required Locations. Class I standpipe systems shall be installed throughout buildings where the floor level of the highest story is located more than thirty feet (30', 9.144 m) above the lowest level of the Fire Department vehicle access, or where the floor level of the lowest story is located more than thirty feet (30', 9.144 m) below the highest level of Fire Department vehicle access. Class I standpipe systems shall be installed throughout buildings where the floor level of the highest story is less than thirty feet (30', 9.144 m) above the lowest level of the Fire Department vehicle access, but the length of hose laid by the Fire Department is greater than one hundred fifty feet (150') from the point of the Fire Department vehicle's access to the furthest point in the building. 905.4.3: Standpipe Hose Connections: All standpipe hose connections shall include a two and one-half inch connection with a cap attached to a chain. The hose connections shall be installed on a forty-five degree (45°) angle towards the floor level unless otherwise approved by the Fire Official. 906.3 Size and distribution. The size and distribution of portable fire extinguishers shall be in accordance with Section 906.3.1 through 906.3.4. In new structures or occupancies, the minimum size fire extinguishers installed shall be 4A:60B:C (Ten (10) Pound). 906.6.1: Fire Extinguisher Signage: Projection style signage shall be installed above each extinguisher to identify the location. The sign shall be installed at a height of approximately six to seven feet (6' to 7') above the standing surface where the extinguisher is mounted. Style of that sign must be approved by the Fire Official. 907.4.3.1: Smoke Detectors, Where Required: Smoke detectors, installed as part of an approved automatic fire alarm system, shall be installed at the top of all interior stairways and elevator shafts unless otherwise directed by the Fire Official. 914.3.1.2: Water supply to required fire pumps: Required fire pumps for high-rise buildings shall be supplied by connections to at least two (2) water supplies. The two (2) connections shall be made to the same main and valved in such that an interruption can be isolated so that the water supply will continue without interruption through at least one (1) of the connections. Each connection and the supply piping between the connection and the pumps shall be sized to supply the flow and pressure required for the pumps to operate and be provided with its own backflow prevention device. Exceptions: Any water supply arrangement that is approved by the Fire Official and Utilities Department. 1023.9: Stairway Identification Signs: An interior exit stairway and ramp shall not continue below its level of exit discharge unless an approved barrier is provided at the level of exit discharge to prevent persons from unintentionally continuing into levels below. Directional exit signs shall be provided as specified in Section 1011. The top of the approved barrier shall not be less than thirty-six inches (36") from the finished floor of the landing. The barrier shall be self-closing. The only approved method of holding the barrier in the open position shall be a magnetic 'hold open' connected to the building fire alarm system. The barrier shall be a contrasting color from the colors in the immediate area. 1023.9.1.1: Signage Requirement: A sign shall be provided at each floor landing in an interior exit stairway and ramp connecting more than two (2) stories designating the floor level, the terminus of the top and bottom of the interior exit stairway and ramp and the identification of the stair or ramp. The signage shall also state the story of, and the direction to, the exit discharge and the availability of roof access from the interior exit stairway and ramp for the Fire Department. The sign shall be located five (5) feet above the floor landing in a position that is readily visible when the doors are in the open and closed positions. In addition to the stairway identification sign, a floor-level sign in raised characters and Braille complying with ICC A117.1 shall be located at each floor-level landing adjacent to the door leading from the interior exit stairway and ramp into the corridor to identify the floor level. 1101.2.1 Rehabilitation Work Area: That portion of a building affected by any renovation, modification, or reconstruction work as initially intended by the owner, and indicated as such in the permit, but excluding other portions of the building where incidental work entailed by the intended work must be performed, and excluding portions of the building where work not initially intended by the owner is specifically required. 1103.1.2 Rehabilitation Work Area: In a building with rehabilitation work areas involving over 50 percent of the aggregate building area, automatic sprinkler and detection, alarm, and communications systems shall be provided throughout the building with the requirements of other sections of this Code applicable to new construction for the occupancy. Exception: One- and Two-Family Dwellings. 1103.1.3 Change of Occupancy: Where a change of occupancy classification occurs, automatic sprinkler and detection, alarm, and communications systems shall be provided throughout the building with the requirements of other sections of this Code applicable to new construction for the occupancy created by the change. In a change of occupancy where the fire area is less than 5,000 square feet, a fire alarm signaling system in accordance with NFPA 72 remote or central supervision station will be required. In a change of occupancy where the fire area is 5,000 or greater, an automatic sprinkler system and detection alarm will be required. 1103.7.5.2 Group R-1 boarding and rooming houses manual fire alarm system. A manual fire alarm system that activates the occupant notification system in accordance with Section 907.6 shall be installed in existing Group R-1 boarding and rooming houses. Exception: Buildings less than two (2) stories in height where all sleeping units, attics, and crawl spaces are separated by one (1)-hour fire-resistance-rated construction and each sleeping unit has direct access to a public way, egress court or yard. Buildings equipped with an approved automatic sprinkler system that is monitored in accordance with Section 903.4.1. 5601.1.3: Fireworks and Explosives: The possession, manufacture, storage, sale, handling and use of fireworks and explosives are prohibited except as approved by the Fire Official. 5602.1: The following terms are defined in Chapter 2: 5602.1: Fireworks: Fireworks include any combustible or explosive composition, and any substance and combination of substances and articles prepared for the purpose of producing a visible or an audible effect by combustion, explosion, deflagration or detonation. Fireworks shall include blank cartridges, toy pistols, toy cannons, toy canes and toy guns in which explosives are utilized; balloons requiring fire underneath to propel the balloon; firecrackers, torpedoes, skyrockets, Roman candles, sparklers and other devices of similar construction; any device containing any explosive or flammable compound; and any tablets and other devices containing any explosive substance. The term "fireworks" shall not include automobile flares or paper caps containing not more than an average of 0.25 grain (16 mg) of explosive content per cap, and toy pistols, toy canes, toy guns, and other devices utilizing such caps. The sale and utilization of types of explosive devices listed herein which are not considered fireworks shall be permitted at all times. 5608.2 Permit application. Prior to issuing permits for a fireworks display, plans for the display, inspections of the display site, and demonstrations of the display operations shall be approved. All requests for permits must be made at least fifteen (15) days in advance of the event unless otherwise approved by the Fire Official. A plan establishing procedures to follow and actions to be taken in the event that a shell fails to ignite in, or discharge from, a mortar so fails to function over the fallout area or other malfunctions shall be provided to the Fire Official.
(Ord. No. 29-O-22, § 4(Exh. C), 4-25-2022)
Ask a question about Evanston law
Corpus searches the Evanston sections it holds and shows the ones that match, with their citations. Free, no sign-in.