4-4-4. - SIGNAL BOOSTING.
(A) Emergency Responder Radio Coverage in Buildings: All buildings shall have approved radio coverage for emergency responders within the building, based upon the existing coverage levels of the public safety communication systems of the City of Evanston at the exterior of the building. This Section shall not require improvement of the existing public safety communication system. Existing buildings that do not have approved radio coverage for emergency responders within the building shall be equipped with such coverage according to one of the following: 1. Wherever existing wired communication system cannot be repaired or is being replaced. 2. Within a time frame established by the Fire Official. (B) Radio Signal Strength: A building shall be considered to have acceptable emergency responder radio coverage when signal strength measurements in ninety-five (95) percent of all areas on each floor of the building meet the following requirements: 1. A minimum signal strength of -95 dBm. 2. A minimum signal strength of -100 dBm received at the closest City of Evanston Radio Communications site. 3. The frequency range which must be supported shall be 151-159 MHz and 450-476 MHz. 4. Starcom 21 frequencies. They have control channels between the 850-860 MHz ranges. When measuring the performance of a bi-directional amplifier, signal strength measurements shall be based on one (1) input signal adequate to obtain a maximum continuous operating output level. (C) Amplification Systems Allowed: Buildings and structures that do not support the required level of radio coverage shall be equipped with either a radiating cable system or an internal multiple antenna system, with or without FCC type accepted bi-directional required MHz amplifiers, as needed. If any part of the installed system or systems contains an electrically-powered component, the system shall be capable of operating on an independent battery and/or generator system for a period of at least twelve (12) hours without external power input. The battery system shall automatically charge in the presence of an external power input. If used, bi-directional amplifiers shall include filters to reduce adjacent frequency interference to at least thirty-five (35) dB below the COE P/S band. The filters shall be tuned to one hundred fifty-four (154) MHz and to four hundred seventy (470) MHz so that they will be thirty-five (35) dB below the COE P/S frequencies of one hundred fifty-four (154) MHz and four hundred seventy (470) MHz respectively. Other settings may be used provided they do not attenuate the COE-P/S frequencies and are not more than one (1) MHz from the COE-P/S frequencies. (D) Testing Procedures: 1. Acceptance Test Procedure: When an in-building radio system is required, and upon completion of installation, it shall be the building owner's responsibility to have the radio system tested to ensure that two-way coverage on each floor of the building is a minimum of ninety-five (95) percent. Each floor of the building shall be divided into a grid of approximately twenty (20) equal areas. No more than one (1) such area shall be allowed to fail the test. In the event that two (2) or more of the areas fail the test, in order to be more statistically accurate, the floor may be divided into forty (40) equal areas. In such event, no more than two (2) nonadjacent areas will be allowed to fail the test. If, after the forty (40)-area test, the system continues to fail, the building owner shall have the system altered to meet the ninety-five (95) percent coverage requirement. The test shall be conducted using a Motorola HT1250, or equivalent, portable radio, talking through the City of Evanston Radio Communications System (COE-911) as specified by the authority having jurisdiction. A spot located approximately in the center of a grid area shall be selected for the test, then the radio shall be keyed to verify two-way communications to and from the outside of the building through the City of Evanston 911 center. Once the spot has been selected, prospecting for a better spot within the grid area shall not be permitted. The building owner shall keep the gain values of all amplifiers and the test measurement results on file so that the measurements may be verified each year during annual tests. In the event that the measurement results are lost, the building owner shall repeat the acceptance test to reestablish the gain values. 2. Annual Tests: When an in-building radio system is required, the building owner shall test, at once every twelve (12) months, all active components of the system, including, but not limited to, amplifiers, power supplies and backup batteries. Amplifiers shall be tested to ensure that the gain is the same as it was upon initial installation and acceptance. Backup batteries and power supplies shall be tested under load for a period of one (1) hour to verify that, they will properly operate during an actual power outage. If, within the one (1) hour test period, the battery exhibits symptoms of failure in the opinion of the testing technician, the test shall be extended for additional one (1) hour periods until the testing technician confirms the integrity of the battery. All other active components shall be checked to determine that they are operating within the manufacturer's specifications for the intended purpose. 3. Five Year Tests: In addition to the annual test, the building owner shall perform a radio coverage test at least once every five (5) years to ensure that the radio system continues to meet the requirements of the original acceptance test. The procedure set forth above shall apply to such tests. 4. Qualifications of Testing Personnel: All tests shall be conducted, documented and signed by a person in possession of a current FCC license, or a current technician certification issued by the Associated Public-Safety Communications Officials International (APCO) or the Personal Communications Industry Association (PCIA). All test records shall be retained on the inspected premises by the building owner and a copy submitted to the Fire Official. (E) Field Testing: Police and fire personnel, after providing reasonable notice to the owner or his representative, shall have the right to enter onto the property to conduct field testing to be certain that the required level of radio coverage is present. (F) Maintenance: The public radio coverage system shall be maintained operational at all times.
(Ord. No. 29-O-22, § 4(Exh. C), 4-25-2022)
Ask a question about Evanston law
Corpus searches the Evanston sections it holds and shows the ones that match, with their citations. Free, no sign-in.