4-5-2. - AMENDMENTS.

The 2014 Illinois Plumbing Code adopted hereby shall read as follows with respect to these Sections. Subsection 890.1130(g): g) Installation of Devices or Assemblies 1) A backflow prevention device shall be installed on each water service pipe/line to a business, commercial, or industrial facility in accordance with the Illinois Plumbing Code. This requirement applies whenever there is an installation of a water service pipe/line, or alteration, renovation, or replacement of an existing pipe/line, and for new construction. A reduced pressure principle backflow, prevention assembly (RPZ) shall be installed in the water service supplying food service, manufacturing, or production establishments. Subsection 890.1150(a)(3): a) 3) The minimum depth for any water service pipe shall be at least 60" deep or the maximum frost penetration of the local area, whichever is greater. Subsection 890.1190(b): b) The water meter shall be installed within the building within 60" of the water service entrance. The meter shall have unions on the inlet and outlet openings. A full-port valve with an open area at least that of the water service shall be provided for all meters and shall be provided with a drain valve installed on the discharge side of the meter valve when located inside of a building. (See Appendix I, Illustrations H and I.) Subsection 890.1200(a): a) Water Service Piping Sizing. The water service pipe from the street main (including the tap) to the water distribution system for the building shall be sized in accordance with Appendix A, Tables M, N, O, P, and Q. Water service pipe and fittings shall be at least one inch in diameter. If flushometers or other devices requiring a high rate of water flow are used, the water service pipe shall be designed and installed to provide this additional flow. Approved Materials for Water Service Pipe 1) Cast Iron (ductile iron) 2 ASTM A 377-2008e1 Water Pipe CSA B70-2012 2) Copper/Copper Alloy Tubing 2,3 ASTM B 88-2009 1 Solvent cement must be handled in accordance with ASTM F 402-1988. 2 Water service pipe must meet the appropriate NSF standard for potable water. 3 Minimum Type K copper shall be installed underground.

(Ord. No. 29-O-22, § 5(Exh. D), 4-25-2022; Ord. No. 106-O-24, § 3, 12-9-2024)

Ask a question about Evanston law

Corpus searches the Evanston sections it holds and shows the ones that match, with their citations. Free, no sign-in.