4-5-3. - ADDITIONAL REQUIREMENTS.

The following are requirements additional to the 2014 Illinois Plumbing Code. In the event that any provision of City Code Section 4-5-3 is in conflict with the 2014 Illinois Plumbing Code, as amended, the 2014 Illinois Plumbing Code shall prevail. (A) Safety: Any part of a structure or premises which is changed, altered, or for which replacement is required as a result of the installation, alteration, renovation, or replacement of a plumbing system, or any part thereof, shall be left in a safe, nonhazardous condition. All penetrations through fire rated construction shall be fire stopped with a through penetration protection system approved by the Building Official. (B) Installation: All plumbing installed within the City of Evanston shall be installed in accordance with the 2014 Illinois Plumbing Code. If required by the Code Official, an approved backflow prevention device is necessary for the safety of the public water supply system, the Public Works Agency Director or his/her designee will give notice to the property owner or person in charge (collectively, "property owner") of the building structure or premises to install such an approved device immediately. The property owner shall, at his/her own expense, immediately install such an approved device at a location and in a manner in accordance with the 2014 Illinois Plumbing Code; Illinois Environmental Agency Rules and Regulations, Title 35: Environmental Protection, Subtitle F: Public Water Supply, Chapter I: Pollution Control Board, Part 604 Subpart O: Cross Connections and Chapter II: Environmental Protection Agency, Part 653 subpart H Cross Connections; and all applicable local regulations, and shall have inspections and tests made of such approved devices upon installation and annually thereafter, at a minimum. The property owner shall maintain records to document that testing, servicing, and repairs are conducted as required. (C) Right of Entry: A City inspector, who shall be a licensed plumber, shall have the right to enter at any reasonable time any property served by a connection to the public water supply or distribution system of the City for the purpose of verifying information submitted by the property owner or person in charge of the building, structure, or premises regarding the required cross connection control inspection. On demand, the property owner or person in charge of the building, structure, or premises so served shall furnish to the Code Official, his/her authorized agent, or approved cross connection control device inspector any information which these individuals may request regarding the piping system or systems or water use on such property. The Code Official or his/her authorized agents shall have a right to enter at any reasonable time any property served by a connection to the public water supply or distribution system of the City for the purpose of verifying information submitted by the property owner or person in charge of the building, structure, or premises regarding the required cross connection inspection. (D) Contamination: The occupant or property owner of the building, structure, or premises responsible for back siphoned material or contamination of the potable water supply system which occurs through an illegal cross connection or an improperly installed, maintained, or repaired device, or a device which has been bypassed, must bear the cost of cleanup of the potable water supply system. Said costs to include, but not be limited to, overhead and administrative costs of the City and any other costs reasonably incurred by the City in the cleanup. (E) Discharge to Sanitary Drainage System: Every plumbing fixture, drain, appliance, or appurtenance thereof which is to receive water or waste, or discharge any liquid wastes or sewage, shall discharge to the sanitary drainage system of the structure in accordance with the requirements of this Chapter. Building drains shall be constructed of either service weight cast iron or schedule 40 PVC pipe and fittings or a material approved by the City Plumbing Inspector. Building sewers shall be constructed of either service weight cast-iron, schedule 40 PVC pipe and fittings, SDR 26 or SDR 35 or a material approved by the City Plumbing Inspector. Underground piping shall be laid on a firm bed of sand or gravel for its entire length, except where support is otherwise provided and approved by a City Plumbing Inspector. Six (6) inches of compacted stone, sand, or other approved material shall be provided under pipe and minimum of twelve (12) inches of stone or sand shall be provided above the crown of the pipe. The remaining soil fill shall be compacted in compliance with Metropolitan Water Reclamation District bedding regulations. (F) Automatic Clothes Washing Machine/Water Heater Floor Drains: For all new construction, a pan or receptor with a drain to an approved floor drain, or an impervious floor with a floor drain, shall be required for all automatic clothes washing machines and water heaters in multi-family and commercial occupancies. For existing multi-family and commercial buildings, a pan and automatic shut-off valve shall be required for all automatic clothes washing machines and water heaters where installation of a floor drain is not feasible. (G) Underground Piping: Piping installed in underground plumbing systems shall be protected from structural damage by an approved method of installation which accounts for the conditions of the installation and application and the type of piping material. In new construction, all plumbing shall be overhead. All fixtures below grade shall be directed to an ejector pit and lifted to an overhead system. Footings, grade beams and/or foundation walls shall be properly sleeved or cored in compliance with a design from a licensed design professional to accommodate for the proper installation of the buildings plumbing system. (H) Sillcocks: All buildings have a minimum of two (2) frost-proof, anti-siphon type sillcocks. (I) Public Toilet Room Drains: All public toilet rooms, including employee facilities, shall be graded into floor drains. (J) Unmaintained Plumbing Fixtures: All plumbing fixtures not maintained shall be disconnected, removed, and sealed. (K) Sewer Depth: Building sewers shall be installed below frost line depth per IRC Table R301.2(1). Current frost line depth is forty-two (42) inches. (L) Subsoil Drain Pipe: Subsoil drains shall be open jointed, horizontally split or perforated pipe. Footing drains to be connected to the sump pump as discharge shall terminate water discharge to grade a minimum of three (3) feet away from any portion of the structure and not within ten (10) feet of any property line or as approved by the Civil Reviewer. Water discharge shall not be directed toward adjacent properties or discharge in a manner that will disturb adjacent properties. Discharge to storm or combination sewer will be upon approval the Public Works Director, Civil Engineer Reviewer or his/her designee. Discharge to sanitary sewer shall not be allowed. All windows wells require drains. The drains shall be connected to drain tile and drain into the sump. (M) Roof Drains: Roof drains shall conform to ASME A112.21.2. Buildings in R1, R2 and R3 zoning districts, and all one- and two-family dwelling units shall drain roof stormwater by gutters and downspouts to the front and rear of the property, Water discharge shall terminate to grade a minimum of three (3) feet away from any portion of the structure and not within ten (10) feet of any property line or as approved by the Civil Reviewer. Water discharge shall not be directed toward adjacent properties or discharge in a manner that will disturb adjacent properties. No connections to the combined or sanitary sewer shall be made in the above zoning districts. All roofs of buildings not mentioned above may drain directly in the storm sewer system. (N) Car Wash Facilities: Unless designed to use thirty (30) gallons or less of water per wash, new car wash facilities or replacement of existing facilities shall be equipped with water recycling systems. (O) Reduced Pressure Principle Backflow Preventers: A reduced pressure principle backflow prevention assembly (RPZ) shall be installed in the water service supplying food service, manufacturing or production establishments. RPZs shall conform to ASSE 1013, 1047 AWWA C511 or CSA CAN/CSA-B64.4. These devices shall be allowed where subject to continuous pressure conditions. The relief opening shall discharge by air gap and shall be prevented from being submerged. (P) All-Gender Restrooms: Restrooms intended for use by all genders shall comply with applicable State laws, including the Equitable Restrooms Act (410 ILCS 35). (Q) Protection Against Physical Damage: In concealed locations where piping, other than cast iron, is installed through holes or notches in studs, joists, rafters or similar members less than 11/4 inches (32 mm) from the nearest edge of the member, the pipe shall be protected by steel shield plates. Such shield plates shall have a thickness of not less than 0.0575 inch (1.463 mm) (No. 16 gage). Such plates shall cover the area of the pipe where the member is notched or bored, and shall extend not less than two (2) inches (51 mm) above sole plates and below top plates.

(Ord. No. 29-O-22, § 5(Exh. D), 4-25-2022; Ord. No. 106-O-24, § 3, 12-9-2024)

Ask a question about Evanston law

Corpus searches the Evanston sections it holds and shows the ones that match, with their citations. Free, no sign-in.