4-6-3. - AMENDMENTS.
The 2020 National Electrical Code adopted hereby shall read as follows with respect to the indicated Sections: Article 210.8 (A)(5), Ground-Fault Circuit-Interrupter Protection for Personnel Exception to (5): Add sump pumps and ejector pumps Article 210.11(3) Bathroom Branch Circuits: Delete the Exception. Article 210-70 Lighting Outlets Required (A)(2): (Add the following) (4) All exterior lighting shall be designed, shielded and directed so that direct light from the lamp does not cause light trespass and protects adjacent properties and public ways from glare and excessive lighting. Light level at any property line is limited to one-half (0.5) foot-candle unless otherwise regulated by city code. Exception: 1. Security lighting: Exterior lighting installed primarily for safety or emergency shall be permitted provided that said lighting is solely for security and activated by a motion or a controlled system and shall be extinguished within 5 minutes of cessation of actual or perceived emergency. 2. Holiday lighting: Subject to NFPA 70 National Electric Code regulations as adopted and amended by the City of Evanston. Article 230 Services: Add the following: "The maximum number of branch circuits allowed for a 100-amp, 120/240 volt, single phase service is thirty (30). The maximum number of branch circuits allowed for a 200-amp, 120/240 volt, single phase service is sixty (60)." Article 230 Services: Add the following: "No additional fuse or breaker boxes shall be installed without the prior written approval of the city's Electrical Inspector." Article 250.62: Grounding Electrode Conductor Material: Delete the words "Aluminum" and "Copper Clad Aluminum." Article 334 Nonmetallic Sheathed Cable: Types NM, NMC, and NMS: Delete. Article 338 Service Entrance Cable: Types SE and USE: Delete. Article 352 Polyvinyl Chloride Conduit: Type PVC 352.12(A) Concealed: PVC conduit shall only be concealed in the following manner: direct buried below grade, in slab below grade, in slab at and above grade. PVC conduit stub ups where subject to physical damage shall be RMC, IMC, or EMT. Article 362 Electrical Nonmetallic Tubing: Types ENT: Add the following: 1) Shall not be used for Electrical Power and Lighting Circuits. 2) When not concealed inside walls and ceilings, only Plenum Rated ENT shall be installed. Article 625.43 Disconnecting Means. Revise this article to read as follows: The disconnecting means shall be provided and installed in a readily accessible location. The disconnecting means shall be lockable open in accordance with 110.25. Appeals: Delete.
(Ord. No. 29-O-22, § 6(Exh. E), 4-25-2022; Ord. No. 106-O-24, § 4, 12-9-2024)
Ask a question about Evanston law
Corpus searches the Evanston sections it holds and shows the ones that match, with their citations. Free, no sign-in.