4-6-6. - ADDITIONAL REGULATIONS.
(A) Treatment of Aluminum Wire: All aluminum wire installed in any installation shall be wire brushed and treated with a compound according to manufacturers' recommendations. (B) Reserved. (C) Luminaires: Luminaires two square feet (2 ft 2 ) and larger located in framing members of a suspended ceiling shall be supported to the structure by a minimum of two (2) pencil rods or other approved means. (D) Receptacle Outlets: Receptacle outlets connected to small appliance branch circuits, as required by Art. 210.52(B)(1), shall be 20 amp rated devices.
(Ord. No. 29-O-22, § 6(Exh. E), 4-25-2022)