§ 121-10 — Design and layout standards

Code of Ordinances of the City of Rockford, Illinois (Supp. No. 18: codified through Ordinance No. 2024-245-O, enacted December 2, 2024) · Rockford Code of Ordinances § 121-10

Corpus is an independent public-information project, not the official City of Rockford website. Stable reference: corpuslaw.us/code/93bc85fe-d6a2-4542-a98b-aac729edc9db

Sec. 121-10. - Design and layout standards.

(a) Design and construction of public improvements. All public improvements shall be designed and constructed in each new subdivision in accordance with the standards and requirements described in the current engineering design criteria for public works improvements and the stormwater technical guidance manual. (b) Streets. (1) Location of street rights-of-way. Location of street rights-of-way shall be in conformance with the currently adopted official plan and other city-council-approved plans. (2) Street patterns. The street pattern in subdivisions shall be based on topographic conditions, drainage, public convenience, safety, and the proposed land uses to be served, and shall provide for the alignment and continuation of existing rights-of-way, and also access to adjacent undeveloped land. Where continuation is impractical, offset intersections shall be permitted with a minimum offset of 150 feet, measured from centerline to centerline. Streets shall be located on the edge of or one lot depth from the edge of the tract. (3) Street types. a. Principal arterial streets. 1. No direct access from individual lots; 2. Right-of-way width shall be in accordance with the current version of the engineering design criteria for public works improvements. b. Minor arterial streets. 1. No direct access from individual lots is permitted; 2. Right-of-way width shall be in accordance with the current version of the engineering design criteria for public works improvements. c. Collector streets. 1. May provide direct access. 2. Right-of-way width shall be in accordance with the current version of the engineering design criteria for public works improvements. d. Local streets. 1. Provide direct access; 2. Sixty feet of right-of-way. e. Half-streets. Half-streets shall not be permitted, except to provide right-of-way for officially adopted planned streets. f. Culs-de-sac. Culs-de-sac designed to be permanent shall be limited to a length of 500 feet, measured from the centerline of the intersection to the center of the circle. The right-of-way diameter shall be a minimum of 120 feet, with a 90-foot diameter improvement. Culs-de-sac are prohibited where street connections are possible. g. Private streets shall not be allowed. When approved by the city council within a planned residential development or planned unit development, private streets may be permitted if the developer of the subdivision has adequately provided for the future maintenance of the roadways. The property owner shall provide a dedicated cul-de-sac on the property for any public stub streets immediately adjacent to the property. The owner shall also provide and maintain at the owner's expense street signs in compliance with the specifications of the department of public works identifying the streets as private. Private streets shall be built in accordance with the specifications of the department of public works. h. Stub streets. Stub streets shall be provided to serve as access to adjacent undeveloped property. Construction of a temporary paved turnaround within an easement is required to provide for adequate fire protection when the stub street length is more than one lot depth or greater than 150 feet, whichever is less. When the stub street is extended by further platting, the temporary turnaround shall be removed by the developer extending the street. If for any reason the stub street is not extended by the developer of the proposed plat, a permanent turnaround shall be constructed on the proposed development by the developer. If a temporary turnaround is not required for the stub street, traffic control devices as required by the traffic engineer shall be installed. i. Dead-end streets. Dead-end streets are not permitted. (c) Sidewalks. (1) Sidewalks shall be installed by the developer along both sides of all streets within the public right-of-way. If topography or existing trees create a logistical problem, the city engineer will determine the most appropriate location for sidewalk construction. (2) In the event that the city engineer determines that an appropriate location for sidewalk construction in the subdivision does not exist, the developer shall deposit an amount to be determined by the city engineer based upon the product of the lineal foot of right-of-way multiplied by the average lineal foot cost of sidewalk for the subdivision as reviewed and approved within the construction plans. This amount shall be directed to the city capital improvement program for pedestrian improvements. (3) The city has designated certain public streets as locations for the installation of a multi-purpose path instead of sidewalks. These locations are designated within Rockford Metropolitan Agency for Planning's document "Rockford Area Transportation Study Pedestrian & Bicycle Plan" and subsequent updates. If development is proposed adjacent to these designated locations, it shall be the responsibility of the developer to install the multi-purpose path. In the event that the city engineer determines the multi-purpose path is unfeasible, he will have the discretion to require the installation of sidewalks or have the developer deposit an amount equal to the construction of the multi-purpose path. This amount shall be based upon the product of the lineal foot of right-of-way multiplied by the average lineal foot cost of the multi-purpose path within standard construction plans. This amount shall be directed to the City of Rockford Capital Improvement Program for pedestrian improvements. (d) Block length. Block length shall not exceed 1,320 feet (one-quarter mile). (e) Lots. (1) Lot layout. a. The number of dwelling units in a development shall not exceed 40 unless a second public access is provided. b. A minimum of 20 feet of frontage on a public street shall be provided for each lot. Lots abutting principal and minor arterial streets shall have access to internal streets only. c. Building setback lines shall equal one-half the right-of-way, not to exceed 40 feet or in accordance with the zoning ordinance. d. Stormwater detention areas shall be included as portions of platted lots and not be established as separate unbuildable lots except when provisions have been made by the developer of the subdivision to establish a special service area or a homeowners association/condominium regulations/covenants and restrictions with provisions for a backup special service area for the maintenance of the lot, and subject to the approval of the public works department. (2) Lot size. a. Residential lots shall meet the minimum width, depth, area and density requirements as set forth in the current zoning ordinance of the city. b. Commercial and industrial lots shall be designed to meet setbacks, off-street loading, parking and landscaping requirements as set forth in the zoning ordinance of the city. c. Corner lots shall be designed so that structures can conform to front yard setbacks on both streets. d. Flag lots shall not be allowed. The city engineer, in his or her discretion with the advice and consent of the city council, may determine based upon the location, platted land configuration or topography of a lot that a flag lot is appropriate. e. Residual parcels. Subdivisions shall not contain or create leftover pieces, corners or remnants of land. (f) Easements. (1) Electrical, cable and telephone utility easements. Electrical, cable and telephone utility easements not less than six feet wide shall be provided on each side of rear lot lines and, where necessary, to provide continuity or provide streetlights, alongside lot lines. Exact locations and widths are subject to the requirements of the utility company. Easements for street lighting shall be provided subject to the current edition of the street lighting policy for the city and the engineering design criteria for public works improvements. (2) Sanitary sewer and water main easements. Sanitary sewer and water main easements shall be located on private property only when necessary and shall be an exclusive easement for the sanitary sewer or water utility, and shall be a minimum of 20 feet wide. The water main shall be centered in easement. Sanitary sewer and water main easements may be located on private property pursuant to this chapter. (3) Storm sewer and drainage easements. Storm sewer and drainage easements shall be of a necessary width, based on engineering standards, to carry surface water runoff to stormwater detention areas and to existing storm sewer systems and shall be a minimum of ten feet wide. (g) Spite strips and restricted access. Reserved or spite strips controlling access to street or to adjacent property are not permitted. Any restricted access from public street to private streets is not permitted, including but not limited to gates, except in conjunction with a planned residential or planned unit development.

(Code 1970, § 27-10; Ord. No. 1989-295-O, 11-6-1989; Ord. No. 1992-1-O, 1-13-1992; Ord. No. 1997-101-O, 6-2-1997: Ord. No. 2002-130-O, 5-28-2002; Ord. No. 2007-277-O, § 27-10, 12-17-2007; Ord. No. 2015-169-O, 8-17-2015)

Ask a question about Rockford law

Corpus searches the Rockford sections it holds and shows the ones that match, with their citations. Free, no sign-in.