§ 170.11.04. - Footings design.
(a) A trench footing, defined as a footing which is constructed by solidly filling a trench with concrete may be used under the following conditions: NOTE: The following three conditions do not apply to a trench footing which is 16 inches or wider.) (1) For one story single family construction, concrete slab on grade, non-load bearing walls, the trench footing width shall be at least eight inches. (2) For one story single family construction, concrete slab on grade, load-bearing walls, the trench footing width shall be at least eight inches, unless soil conditions require a wider trench footing or traditional spread footing. (3) Trench footings are not allowed for two-story construction. (b) The design depth for frost shall be 36 inches below the finished grade. (c) No reduction may be made to the required foundation width except for four-inch wide by eight-inch high recessed pocket to allow for installation of brick veneer. If the recessed pocket needs to be higher than eight inches, the foundation width must be increased by at least two inches. _____
(Ord. No. 826-12-06, § 1(Exh. A), 12-19-06)