§ 170.11.05 — Foundation for stud bearing wall; minimum requirements based on minimum of 2,000 PSF soil bearing pressure

Code of Ordinances, City of Springfield, Illinois (Supp. No. 82: codified through Ordinance No. 146-04-26, enacted April 7, 2026) · Springfield, Ill., City Code § 170.11.05

Corpus is an independent public-information project, not the official City of Springfield website. Stable reference: corpuslaw.us/code/3a3a9410-bff4-42d9-b2ee-59686aa4ee9b

§ 170.11.05. - Foundation for stud bearing wall; minimum requirements based on minimum of 2,000 PSF soil bearing pressure.

(a) Where soil bearing pressure is 2,000 PSF, the following shall apply: Number of Floors Supported by the Foundation | Minimum Width Foundation Wall (Inches) | Minimum Width of Footing (Inches) | Minimum Thickness of Footing (Inches) | Minimum Depth Below Adjacent Final Grade (Inches) Concrete | Unit Masonry 1 | 6 | 8 | 16 | 8 | 36 2 | 8 | 8 | 16 | 8 | 36 3 | 10 | 12 | 18 | 12 | 36 (b) Except for one- and two-family dwellings, the PSF soil bearing pressure shall be provided to the building official when making application for a building permit. (c) Where unusual conditions or frost conditions are found, footings and foundations shall be as required in the International Building Code. (d) The ground under the floor may be excavated to the elevation of the top of the footing. (e) The foundation may support a roof in addition to the stipulated number of floors. Foundations supporting roofs only shall be as required for supporting one floor.

(Ord. No. 826-12-06, § 1(Exh. A), 12-19-06)