§ 172.11.07. - Hydro-massage bathtub electrical accessibility.

Section 680.73 of the NEC requires electrical equipment for hydro-massage bathtubs to be accessible without damaging the building structure or building finish. This accessibility must be achieved by means of an access panel provided on the same floor level as the hydro-massage tub. It is not acceptable to provide accessibility to a first floor hydro-massage bathtub from the basement, or to a second floor hydro-massage bathtub from the first floor. The contractor must remove the access panel prior to calling for a final inspection.

(Ord. No. 826-12-06, § 1(Exh. A), 12-19-06)