§ 13.10.160 — Seepage pit requirements

Municipal Code of the City of Evansville, Indiana (legislation through 06-22-2026) · Evansville Municipal Code § 13.10.160

Corpus is an independent public-information project, not the official City of Evansville website. Stable reference: corpuslaw.us/code/7d905399-1b26-488c-a60c-4b681aabc909

§ 13.10.160: Seepage pit requirements.

(A) The use of seepage pits is permitted with septic tanks when their use is necessary because of soil conditions or topography and when their use is acceptable to the Evansville-Vanderburgh County Health Department. The construction of seepage pits or sewage dry wells in limestone areas or in localities where wells are used as a source of individual supply is prohibited. This is to be interpreted that no seepage pit will be allowed to be constructed within 300 feet of a private water supply unless approved by the Health Department. Where seepage pits are constructed as secondary disposal units, it is necessary to provide the following: (1) A septic tank of the size required by this chapter, and with the installation of two seepage pits connected in a series constructed as described in this chapter. (2) All seepage pits in the series must be installed so that the sewage will overflow from the first pit into the second pit and so on, only after the first pit is entirely filled with sewage. (3) The invert of the outlet from the pit must be at least one inch lower than the invert of the inlet tile. (4) The pits will be connected by sealed joint bell and spigot, vitrified clay pipe which is laid on a slope of at least one-eighth-inch per lineal foot. (B) At the discretion of the Health Department, subsection (A) of this section may be waived if the private sewage disposal system being installed includes a properly constructed sand trap as outlined herein. To fulfill this requirement, the sand trap shall be located in the private sewage disposal system between the septic tank and the seepage pit in such a manner that the outlet line from the septic tank shall connect to the inlet of the sand trap, and the outlet line from the sand trap shall connect to the inlet line of the seepage pit. Where the installation of the sand trap shall result in the waiving of subsection (A) of this section, the minimum septic tank requirements as outlined in EMC § 13.10.130 shall prevail. Where the sand trap is approved for installation in a private sewage disposal system, it shall conform to the following requirements: (1) The minimum inside dimensions shall be three feet in width, 15 feet in length and with a sand depth of 30 inches. (2) The four sides and top of this trap shall be constructed in a manner approved by the Health Department. (3) Each sand trap must have a top and bottom tile line. The top tile shall be located on top of the sand material and not enclosed. The bottom tile shall be located on the bottom of the trap and shall be enclosed in pea gravel. (4) The sand used in any sand trap shall meet the same specifications as outlined in EMC § 13.10.170(C). (C) Location of seepage pits, in addition to the general provisions under subsection (A) of this section, shall be not less than the stated minimum distances from the following: (1) Dwellings, 50 feet. (2) Lot lines, 10 feet. (3) Other seepage pits, 18 feet on center. (4) Private water supply, 300 feet. (D) Construction of all seepage pits shall conform to the following requirements: (1) Before construction, boring results, in the presence of a Health Department representative, must disclose that a sandy soil is present. (2) The minimum depth of a seepage pit will be 20 feet unless otherwise stated by the Health Department. (3) The minimum bottom width of a seepage pit will be five feet in diameter and the minimum top width of a seepage pit will be six feet in diameter. In both cases this shall be interpreted as the distance between the lining material. (4) When seepage pits are used with subsurface disposal trenches, the filter material in the trenches shall terminate at least six feet from the pit excavation, and this section of the trench shall not be excavated below the grade of the tile. (5) Bell and spigot pipe with tight joints shall be used in connecting the tile to the pit. (6) The lining may be brick, stone, block, or similar materials at least four inches thick, laid in cement mortar above the inlet, and dry with open vertical joints below the inlet. When necessary because of soil conditions, the annular space between the lining and the earth wall shall be filled with crushed rock or gravel. The lining of brick, stone, or similar materials must be at least six inches above the top of the inlet and laid in cement mortar. The inlets and outlets must be either ells or tees, which will direct the sewage flow downward and will prevent to a minimum sewage solids from entering the second pit. The inlet and outlet tiles must be sealed in an approved method to the lining. (7) A reinforced concrete top at least four inches thick bearing on at least six inches of soil outside the pit, and with a watertight concrete manhole and cover or other acceptable means of closure, shall be 12 to 18 inches below the ground surface.

( 1962 Code § 1731.17 ; Ord. G-64-8 , passed 7-6-1964 ; 1982 Code § 51.16 ; 1983 Code § 5.51.16 )

Ask a question about Evansville law

Corpus searches the Evansville sections it holds and shows the ones that match, with their citations. Free, no sign-in.