Section 21.12 - Specific Standards
In all SFHAs, the following provisions are required: (a) In addition to the requirements of Section 21.11, all structures to be located in the SFHA shall be protected from flood damage below the FPG. This building protection requirement applies to the following situations: (1) Construction or placement of any new structure having a floor area greater than 400 square feet; (2) Structural alterations made to: a. An existing (previously unaltered) structure, the cost of which equals or exceeds 50 percent of the value of the pre-altered structure (excluding the value of the land); b. Any previously altered structure. (3) Reconstruction or repairs made to a damaged structure that are valued at or more than 50 percent of the market value of the structure (excluding the value of the land) before damage occurred; (4) Installing a travel trailer or recreational vehicle on a site for more than 180 days; (5) Installing a manufactured home on a new site or a new manufactured home on an existing site. This article does not apply to returning the existing manufactured home to the same site it lawfully occupied before it was removed to avoid flood damage; and (6) Reconstruction or repairs made to a repetitive loss structure. (b) Residential Construction. New construction or substantial improvement of any residential structure (or manufactured home) shall have the lowest floor, including basement, at or above the FPG (two feet above the base flood elevation). Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movements of floodwaters shall be provided in accordance with the standards of [subsection] (d) below. (c) Non-Residential Construction. New construction or substantial improvement of any commercial, industrial, or non-residential structure (or manufactured home) shall have the lowest floor, including basement, elevated to or above the FPG. Structures located in all "A Zones" may be floodproofed in lieu of being elevated if done in accordance with the following: (1) A registered professional engineer or licensed architect shall certify that the structure has been designed so that below the FPG, the structure and attendant facilities are watertight and capable of resisting the effects of the regulatory flood. The structural design shall take into account flood velocities, duration, rate of rise, hydrostatic pressures, and impacts from debris or ice. Such certification shall be provided to the enforcement official, as set forth in Section 21.06(b)(10). (2) Floodproofing measures shall be operable without human intervention and without an outside source of electricity. (d) Elevated Structures. (1) New construction or substantial improvements of elevated structures that include fully enclosed areas formed by foundation and other exterior walls below the FPG shall be designed to preclude finished living space and designed to allow for the entry and exit of floodwaters to automatically equalize hydrostatic flood forces on exterior walls. (2) Structural calculations shall be submitted demonstrating sufficient structural capacity is provided in accordance with this ordinance. (3) Designs for complying with this requirement must either be certified by a professional engineer or licensed architect or meet the following minimum criteria: a. Provide a minimum of two openings that have a total net area of not less than one square inch for every one square foot of enclosed area; b. The bottom of all openings shall be no higher than one foot above foundation interior grade (which must be equal to in elevation or higher than the exterior foundation grade); c. Openings may be equipped with screens, louvers, valves or other coverings or devices provided they permit the automatic flow of floodwaters in both directions; d. Access to the enclosed area shall be no more than the minimum necessary to allow for parking vehicles (garage door) or limited storage of maintenance equipment used in connection with the premises (standard exterior door) or entry to the living area (stairway or elevator); e. The interior portion of the enclosed area shall not be partitioned or finished into separate rooms; and f. Portions of the building below the FPG must be constructed with materials resistant to flood damage. (4) Where elevation requirements exceed six feet above the highest adjacent grade, a copy of a legally recorded deed restriction prohibiting the conversion of the area below the lowest floor to a use or dimension contrary to the structure's originally approved design, shall be presented as a condition of issuance of the final certificate of occupancy. (e) Structures Constructed on Fill. A residential or nonresidential structure may be constructed in a permanent fill in accordance with the following: (1) The fill shall be placed in layers no greater than one foot deep before compacting to 95 percent of the maximum density obtainable with the Standard Proctor Test method. (2) The fill shall extend at least ten feet beyond the foundation of the structure before sloping below the FPG. (3) The fill shall be protected against erosion and scour during flooding by vegetative cover, riprap, or bulkheading. If vegetative cover is used, the slopes shall be no steeper than three horizontal to one vertical. (4) The fill shall not adversely affect the flow of surface drainage from or onto neighboring properties. (5) The top of the lowest floor, including basements, shall be above the FPG. (f) Structures Constructed with a Crawlspace. A residential or nonresidential structure may be constructed with a crawlspace located below the FPG, provided that the following conditions are met: (1) The building must be designed and adequately anchored to resist flotation, collapse, and lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy; (2) Any enclosed area below the FPG shall have openings that equalize hydrostatic pressures by allowing for the automatic entry and exit of floodwaters. (3) A minimum of two openings having a total net area of not less than one square inch per square foot of enclosed area is provided. The bottom of the openings shall be no more than one foot above grade; (4) The interior height of the crawlspace measured from the interior grade of the crawlspace to the top of the foundation wall must not exceed four feet at any point; (5) Utility systems within the crawlspace must be elevated above the FPG; (6) An adequate drainage system must be installed to remove floodwaters from the interior area of the crawlspace within a reasonable period of time after a flood event; (7) Portions of the building below the FPG must be constructed with materials resistant to flood damage; and (8) Utility systems within the crawlspace must be elevated above the FPG. (g) Manufactured Homes and Recreational Vehicles. Manufactured homes and recreational vehicles to be installed or substantially improved on a site for more than 180 days must meet the following requirements: (1) The manufactured home shall be elevated on a permanent foundation such that the lowest floor shall be at or above the FPG and securely anchored to an approved foundation system to resist flotation, collapse, and lateral movement. This requirement applies to all manufactured homes to be placed on a site: a. Outside a manufactured home park or subdivision; b. In a new manufactured home park or subdivision; c. In an expansion to an existing manufactured home park or subdivision; or d. In an existing manufactured home park or subdivision on which a manufactured home has incurred "substantial damage" as a result of a flood. (2) Recreational vehicles placed on a site shall either: a. Be on site for less than 180 days; b. Be fully licensed and ready for highway use (defined as being on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions); or c. Meet the requirements for "manufactured homes" as state earlier in this section.
Ask a question about Michigan City law
Corpus searches the Michigan City sections it holds and shows the ones that match, with their citations. Free, no sign-in.