Sec. 50.43. - Use of "Y" branch for connection; exception.

The connection between the building sewer and the sanitary district's sewer shall be made at the "Y" or "T" branch provided, there is one. Where no "Y" branch was left for the building sewer, a hole may be cut in the sanitary district's sewer large enough to receive the end of the building sewer, and the connection made so that the building sewer enters the municipal sewer at an angle. In no case shall the spigot end extend past the inside surface of the municipal sewer. A smooth joint shall be made and the connection made secure and watertight by encasing with concrete. The person securing the permit shall notify the commissioners when the work will be completed and ready for an inspection. No backfill shall be placed over any connection made with the sanitary district's sewer until it has been inspected and approved by the commissioners or their authorized representative. Such inspection shall be made within 30 hours after the receipt of notice that the connection is made and ready for inspection.

(Code 1968, § 50.43)