For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 53.53 — Sample collection

Code of Ordinances of the City of Muncie, Indiana (Codified through Ordinance No. 5-26 enacted January 5, 2026. (Supp. No. 34)) · Muncie Municipal Code § 53.53

Corpus is an independent public-information project, not the official City of Muncie website. Stable reference: corpuslaw.us/code/6b4fd0e7-2f7c-402f-a434-8bedf1611ec0

Sec. 53.53. - Sample collection.

Samples collected to satisfy reporting requirements must be based on data obtained through appropriate sampling and analysis performed during the period covered by the report, and based on data that is representative of conditions occurring during the reporting period. (A) Except as indicated in section (B) and (D) below, the IU must collect wastewater samples using 24-hour flow proportional composite collection techniques. In the event flow proportional sampling is infeasible, the director may authorize the use of time proportional sampling or grab samples where the user demonstrates that this will provide a representative sample of the effluent being discharged. Using protocols (including appropriate preservation) specified in 40 CFR 136 and appropriate EPA guidance, multiple grab samples collected during a 24-hour period may be composited prior to analysis as follows: for cyanide, total phenols, and sulfides, the samples may be composited in the laboratory or in the field; for volatile organics and oil and grease, the samples may be composited in the laboratory. Composite samples for other parameters unaffected by the compositing procedures as documented in approved EPA methodologies may be authorized by the director as appropriate. In addition, grab samples may be required to show compliance with daily maximum discharge limits and instantaneous limits. (B) Samples for oil and grease, temperature, pH, cyanide, total phenols, toxicity, sulfides, and volatile organic chemicals must be obtained using grab collection techniques. (C) A categorical industrial user subject to the limits described in Federal 40 CFR of the Act shall take samples immediately downstream from their pretreatment facility if pretreatment exists, or immediately downstream from the regulated process if no pretreatment exists. If other wastewaters are mixed with the regulated wastewater prior to pretreatment, the IU should measure the flows and concentrations necessary to allow use of the combined wastestream formula in order to evaluate compliance with the pretreatment standards. Where an alternate concentration or mass limit has been calculated, this adjusted limit along with the supporting data shall be submitted to the bureau. (D) For sampling required in support of baseline monitoring and 90-day compliance reports described in section 53.43 and 53.45, for facilities which do not have historical sampling data available, a minimum of four grab samples must be used for determination of pH, cyanide, total phenols, oil and grease, sulfide, and volatile organic compounds; for which historical sampling data is available, the director may authorize a lower minimum. For reports required by section 53.46, the IU is required to collect the number of grab samples necessary to access and ensure compliance with applicable pretreatment standards and requirements.

(Ord. No. 1-11, § 1(Exh. A), 2-7-11)

Ask a question about Muncie law

Corpus searches the Muncie sections it holds and shows the ones that match, with their citations. Free, no sign-in.