Sec. 53.62. - FOG pretreatment system requirements.
(A) Except as provided by section 53.63, the wastewater generated from FSEs shall be treated to remove FOG using a FOG interceptor or FOG trap. (B) An application for the design and installation of a FOG pretreatment system shall be subject to review and approval by the director and shall be subject to the sizing guidelines of the Indiana State Board of Health's Bulletin S.E. 13 Sec. 501 and all other applicable codes, ordinances, and laws. (C) Every structure at the FSE shall be constructed, operated and maintained in a manner to ensure that the discharge of food preparation wastewater is directed solely to the FOG interceptor, or alternate FOG pretreatment system. No valve or piping bypass equipment that could prevent the discharge of food preparation wastewater from entering appropriate treatment equipment shall be present. (D) The contact person at each FSE shall notify the bureau of water quality when the FOG pretreatment system is ready for inspection and connection to the public sewer. Newly installed FOG interceptors must be left uncovered to allow for inspection by MSD personnel. Inspections will be carried out within 72 hours of receipt of notification that the interceptor is ready for inspection. (E) All other applicable state and local plumbing/building codes shall be followed during the installation of the FOG pretreatment system. (F) FOG interceptor requirements: (1) The FOG interceptor shall be installed on' a separate building sewer line servicing kitchen flows and shall be connected only to those fixtures or drains which would allow fats, oils, and grease to be discharged. This shall include: (a) Pot sinks; (b) Pre-rinse sinks; (c) Any sink into which fats, oils and grease are likely to be introduced; (d) Soup kettles or similar devices; (e) Wok stations; (f) Floor drains or sinks into which kettles may be drained; (g) Automatic hood wash units; (h) Dishwashers without pre-rinse sinks; and (i) Any other fixtures or drains likely to allow fats, oils and grease to be discharged. (2) All food grinders or food garbage disposals shall discharge to the FOG interceptor, unless specifically stated otherwise in the permit. (3) No fixture or drain other than those listed in section 53.62(F)(1) shall be directly connected to the FOG interceptor unless approved by the director. The following shall not be discharged into FOG interceptor: (a) Waste that does not contain FOG and that otherwise does not require treatment; (b) Wastewater from dish washing machines or wastewater with a temperature exceeding 140°F; (c) Sanitary waste; (d) Any substance that may cause excessive foaming in the MWPCF; (e) Emulsifiers, chemicals, and enzymes. (4) The outlet discharge line from the FOG interceptor shall be directly connected to the municipal sanitary sewer. (5) Separate cleanout covers shall be provided over the inlet and outlet of the FOG interceptor to provide easy access for inspection and cleaning. (G) All costs and related expenses associated with the installation and connection of the FOG interceptor(s) or alternate FOG pretreatment system(s) shall be borne by the FSE. The FSE shall indemnify the Muncie Sanitary District and its agents for any loss or damage that may directly or indirectly occur due to the installation of the FOG pretreatment system.
(Ord. No. 1-11, § 1(Exh. A), 2-7-11; Ord. No. 10-12, § 2, 6-4-12)
Ask a question about Muncie law
Corpus searches the Muncie sections it holds and shows the ones that match, with their citations. Free, no sign-in.