Sec. 53.64. - Pretreatment equipment maintenance.
(A) The FOG pretreatment system shall be maintained continuously in satisfactory and effective operation at the FSE's expense. (B) The contact person or authorized agent shall be responsible for the proper removal and disposal, by appropriate means, of the collected material removed from the FOG pretreatment system. (C) The contact person or authorized agent shall ensure that the FOG interceptor is inspected when pumped to ensure that all fittings and fixtures inside the interceptor are in good condition and functioning properly. The depth of grease inside the tank shall be measured and recorded in the maintenance log during every inspection along with any deficiencies, the date, and the identity of the inspector (see section 53.64(D)(3)). (D) The contact person or authorized agent shall determine the frequency at which its FOG interceptor(s) shall be pumped according to the following criteria: (1) The FOG interceptor shall be cleaned by a subsurface sewage disposal cleaner whenever 25 percent of the operating depth of the FOG interceptor is occupied by fats, oils, grease, and settled solids, or a minimum of once every three months; whichever is more frequent. Cleaning of FOG interceptors shall include the complete removal of all contents, including floating materials, wastewater and settled sludge. Decanting back into the FOG interceptor shall not be permitted unless specific variance is granted in the FSE's permit. FOG interceptor cleaning shall include scraping excessive solids from the wall, floors, baffles and all piping. (2) If the contact person can provide data demonstrating that less frequent cleaning of the FOG interceptor will not result in a grease level in excess of 25 percent of the operating depth of the FOG interceptor, the director may allow less frequent cleaning. The contact person shall provide data including pumping receipts for four consecutive cleanings of the FOG interceptor, complete with a report from the grease trap/interceptor cleaner indicating the grease level at each cleaning, and the FOG interceptor maintenance log. (3) A maintenance log of activities related to the FOG interceptor shall be maintained on the premises, and shall include the following information: dates of all activities related to the FOG interceptor, volume pumped, grease depth, grease trap/interceptor cleaner's name, location of the waste disposal, means of disposal for all material removed from the FOG interceptor, and the name of the individual recording the information. The maintenance log and grease trap/interceptor cleaner's receipts shall be made available to bureau personnel for inspection on demand. Interceptor cleaning and inspection records shall be maintained on file a minimum of five years. (E) All material removed and hauled from FOG pretreatment systems shall be disposed of at a FOG disposal facility approved by the Indiana Department of Environmental Management, or, if taken out of state, approved by a similar state agency. (F) The contact person shall be responsible for the cost and scheduling of all actions needed to comply with this chapter. The contact person shall be notified in writing of violations of this chapter by the director.
(Ord. No. 1-11, § 1(Exh. A), 2-7-11)
Ask a question about Muncie law
Corpus searches the Muncie sections it holds and shows the ones that match, with their citations. Free, no sign-in.