Sec. 5-806. - International Plumbing Code—Sections 312.3 and 3.125 amended.

Sections 312.3 and 3.125 of the 2018 International Plumbing Code are hereby amended to read as follows: 312.3 Drainage and vent water test. An air test shall be made by forcing air into the system until there is a uniform gauge pressure of five psi (34.5 kPa) or sufficient to balance a ten-inch (254 mm) column of mercury. This pressure shall be held for a test period of not less than 15 minutes. Any adjustments to the test pressure required because of changes in ambient temperatures or the seating of gaskets shall be made prior to the beginning of the test period. 312.5 Water supply system test. Upon completion of a section of or the entire water supply system, the system, or portion completed, shall be tested and proved tight under a water pressure not less than the working pressure of the system; or, by an air test of not less than 50 psi (344 kPa). This pressure shall be held for not less than 15 minutes. The water utilized for tests shall be obtained from a potable source of supply. The required tests shall be performed in accordance with this section and section 107.

(Code 2018, § 5-506)

Ask a question about Lawrence law

Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.