§ 5-812 — International Plumbing Code—Sections 1003.2 and 1003.3.1 amended

Code of Ordinances of the City of Lawrence, Kansas (Codified through Ordinance No. 10209, enacted April 14, 2026 (Supp. No. 4)) · Lawrence Code of Ordinances § 5-812

Corpus is an independent public-information project, not the official City of Lawrence website. Stable reference: corpuslaw.us/code/bb145dc1-4d80-4407-957a-9695156d933b

Sec. 5-812. - International Plumbing Code—Sections 1003.2 and 1003.3.1 amended.

Sections 1003.2 and 1003.3.1 of the 2018 International Plumbing Code are hereby amended to read as follows: 1003.2 Approval. The size, type and location of each interceptor and of each separator shall be designed and installed in accordance with the manufacturer's instructions and the requirements of this section based on the anticipated condition of use. Gravity grease interceptors shall be located outside the building in an accessible location; hydromechanical grease interceptors are prohibited; and automatic grease removal devices shall only be installed with the prior approval of the building official. Wastes that do not require treatment or separation shall not be discharged into any interceptor or separator. 1003.3.1 Grease interceptors and automatic grease removal devices required. A grease interceptor or automatic grease removal device shall be required to receive the drainage from fixtures and equipment with grease-laden waste located in food preparation areas, such as in restaurants, hotels, kitchens, hospitals, school kitchens, bars, factory cafeterias, and clubs. Fixtures and equipment shall include pot sings, pre-rinse sinks; soup kettles or similar devices; wok stations; floor drains or sinks into which kettles are drained; automatic hood wash units and dishwashers. Grease interceptors and automatic grease removal devices shall receive waste only from fixtures and equipment that allow fats, oils, or grease to be discharged. Where a lack of space or other constraints prevent the installation or replacement of a grease interceptor, one or more grease interceptors shall be permitted to be installed on or above the floor and upstream of an existing grease interceptor.

(Code 2018, § 5-512)

Ask a question about Lawrence law

Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.