For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-238 — Appendix K

Code of Ordinances of the City of Lawrence, Kansas (Codified through Ordinance No. 10209, enacted April 14, 2026 (Supp. No. 4)) · Lawrence Code of Ordinances § 8-238

Corpus is an independent public-information project, not the official City of Lawrence website. Stable reference: corpuslaw.us/code/03b47ed3-1ca4-40d7-b89c-878c2b27f16a

Sec. 8-238. - Appendix K.

Appendix K of the 2018 International Fire Code is hereby amended to reads as follows: Appendix K. Residential day care facilities. K101. Purpose. The purpose of this appendix is to provide a reasonable degree of safety to children and providers attending residential day care facilities. K102. Scope. The provisions of this appendix shall apply to all newly established or existing licensed and group day care facilities within the city when other provisions and inspections are not provided for by the state office of the state fire marshal. K103. Definitions. (A) Group day care. Care provided for no more than 12 children less than 16 years of age. (B) Licensed day care. Care provided for no more than ten children less than 16 years of age. K104. Exits. (A) Escape corridor. Every escape path, including all stairways, shall be clear of obstructions and all doors shall be in proper working condition. (B) Exit doors. Every required exit door must be capable of being easily opened from the inside at all times when the facility is operating. (C) Exit pathway passing by a basement stairway. If an exit pathway passes by a basement stairway, the stairway must be separated by a door or gate to prevent children from accidentally entering the basement. K105. Doors. (A) Closet doors. At all times, every closet door must be capable of being easily opened from the inside by children. (B) Bathroom doors. Every bathroom door must be capable of being unlocked from the outside at all times. The unlocking key/device must be readily accessible to the staff. K106. Basement and second floor use. (A) Before May 1, 1998. Facilities which possess a certificate or day care license dated before May 1, 1998, may use a basement or second floor for day care only if there are at least two separate exits to the outside. One exit must be a door and one exit may be an approved escape window. Day care providers must be able to demonstrate that everyone under their care can safely exit the house and go to a designated safe area within four minutes. The code official may require day care providers to demonstrate their ability to conduct such an exit drill. (B) On or after May 1, 1998. Facilities which possess a certificate or day care license dated on or after May 1, 1998, may use a basement for day care only if there are at least two exits to the outside. One exit must be a door leading directly to the outside. If the two exits in use are within ten feet of each other, a third exit, which may be an approved exit window, will be required. Residential day care is not allowed on the second floor of a residence. Bi-level houses must be inspected by the code official to determine if they comply with this provision prior to their use as a day care facility. K107. Portable fire extinguishers. (A) Type and location. A fire extinguisher rated at 2A:10B:C: is required and must be placed or mounted so that the unit's operating and mounting mechanisms are located no higher than 48 inches from the floor and no lower than 15 inches above the floor. (B) Maintenance. Fire extinguishers provided for the day care must be inspected and/or serviced and tagged within the previous 12 months by a person or business licensed by the state fire marshal. If the fire extinguisher is purchased new, a purchase receipt must be retained that shows the date of purchase. Such a new fire extinguisher does not need to inspected within the first 12 months after the date shown on the purchase receipt. K108. Smoke detectors. (A) Smoke detector installation. Smoke detectors shall be installed on every level of the residence according to the manufacturer's instructions. Smoke detectors shall be located in the pathways serving sleeping and use areas and in each sleeping room used for children. (B) Smoke detector maintenance. Smoke detectors shall be tested monthly. The batteries in battery-powered smoke detectors shall be changed every six months and records of the tests and battery changes required in this section shall be kept on file for review upon request of the code official. The batteries in standard battery-powered smoke detectors shall be changed every six months and the battery replacement documented with monthly detector tests. Standard battery-powered smoke detectors shall be replaced within ten years of date of manufacture with ten-year lithium or 110 volt interconnected smoke detectors. K109. Heating devices. (A) Venting. All natural gas, kerosene, wood, propane heaters, and other open flame heating devices shall be properly vented to the outside of the residence. (B) Protective barriers. All heating devices shall be shielded by a noncombustible barrier that prevents accidental contact with the devices. (C) Combustible storage. No combustible storage is allowed within 36 inches of the furnace or hot water heater or other open flame device. All heating devices shall be kept clean and dust free. K110. Emergency procedures. (A) Exit drills. Exit drill procedures shall be posted and exit drills shall be conducted monthly. Accurate written records of the exit drills conducted in the previous 12 months shall be kept and posted in plain view at the day care. (B) Tornado procedures. Written emergency procedures for tornadoes shall be posted and shall be practiced monthly. Accurate written records of the emergency tornado procedures practice conducted in the previous 12 months shall be kept and posted in plain view at the day care. K111. General fire safety. (A) Electrical outlets. All unused electrical outlets in licensed areas shall have child-resistant protective covers in place. (B) Flashlights. A working flashlight shall be available for each staff member in the day care.

(Code 2018, § 8-237)

Ask a question about Lawrence law

Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.