Sec. 8-603. - Permits required.

A permit application to use or possess explosive materials subject to regulation under this article shall be made to the division of fire prevention which shall issue the same only if the Lawrence-Douglas County Fire Medical fire marshal or designated representative shall after inspection and review approve issuance of the permit. The Lawrence-Douglas County Fire Medical fire marshal or designated representative shall have seven days after receipt of a completed application to review the application, including all supporting documentation, and to issue or deny a permit. The process to apply for a permit shall be as follows: (a) For blasting operations occurring at a distance greater than 1,500 feet of any structure or utility line: (1) The application for a permit shall be accompanied by a blasting plan for the blasting operation. The blasting plan shall contain the following information: a. The name of the contractor conducting the blasting operation; and b. The names of all responsible on-site personnel with copies of their permits to blast explosives issued by the Lawrence-Douglas County Fire Medical fire marshal. (2) The applicant shall maintain and provide proof of liability insurance coverage for the purpose of payment of damages to persons or property which arise from, or are caused by, the blasting operations. The policy or policies shall provide for the following minimum coverage: a. Liability insurance to cover injuries or damages to persons or property which might result from blasting operations: 1. General aggregate (or a combination of general liability insurance and an umbrella policy insuring the blasting operations): $5,000,000. 2. Each occurrence: $2,000,000.00. b. Automobile liability insurance combined single limit: $1,000,000.00. c. Workers' compensation: statutory coverage. (3) The applicant shall pay an application fee as provided in the city fee schedule. (b) For blasting operations occurring at a distance equal to or less than 1,500 feet and greater than 500 feet of any structure or utility line: (1) The application for a permit shall be accompanied by a blasting plan for the blasting operation. The blasting plan shall contain the following information: a. Name of the contractor conducting the blasting operation. b. Names of all responsible on-site personnel with copies of their permits to blast explosives from the state fire marshal. c. Scale drawing prepared by the city GIS coordinator or designee which accurately allows dimensions and all distances relative to the application to be calculated for the following: 1. Distances to all structures, to the extent such data is available on the city's GIS system, within 1,500 feet of the blast site; 2. Distances from structures to the explosive storage magazines. d. Evidence of the notice required by this article, sent by United States mail, to owners of property and/or utility lines located within 1,500 feet of the blast site. The required evidence shall include a copy of the written notification and a list of names and addresses of those notified. Said written notification shall contain the following information: 1. Notice of intent to blast; 2. Name of the blasting contractor; 3. Estimated duration of blasting operations and the general location of the blast site, with a copy of the map included with the notice; 4. Name of the insurance agency providing the blasting contractor's liability insurance coverage and the agency's contact information; and 5. The date, time, and location of the informational meeting with property owners and/or utility company representatives. e. Proof that the seismology equipment to be used at the blasting site has been calibrated and certified within one year of the proposed blasting. (2) The applicant shall maintain and provide proof of liability insurance coverage for the purpose of payment of damages to persons or property which arise from, or are caused by, the blasting operations. The policy shall provide for the following minimum coverage: a. Liability insurance to cover injuries or damages to persons or property which might result from blasting operations: 1. General aggregate (or a combination of general liability insurance and an umbrella policy insuring the blasting operations): $5,000,000.00. 2. Each occurrence: $2,000,000.00. b. Automobile liability insurance combined single limit: $1,000,000.00. c. Workers' compensation: statutory coverage. (3) The applicant shall pay an application fee as provided in the city fee schedule. (c) For blasting operations occurring at a distance equal to or less than 500 feet of any structure or utility line: No blasting shall occur within 100 feet of any structure or utility line unless the owners of the structures and/or utility lines consent in writing, and the blasting conforms to the limits recommended by the U.S. Bureau of Mines Table of Scaled Distances. (1) The application for a permit shall be accompanied by a blasting plan for the blasting operation. The blasting plan shall contain the following information: a. The name of the contractor conducting the blasting operation; b. The names of all responsible on-site personnel with copies of the blasters certificates; c. Scale drawing prepared by the city GIS coordinator or designee that accurately allows dimensions and all distances relative to the application to be calculated for the following: 1. Distances to all structures, to the extent such data is available on the city's GIS system, within 1,500 feet of the blast site. 2. Distances from structures to the explosive storage magazines. 3. Designation of proposed pre-blast surveyed structures within 500 feet of the blast site. d. Name of the independent firm, approved by the fire prevention division and reporting directly to the fire marshal, which shall conduct the seismographic monitoring of blasts occurring within 500 feet of any structure or utility line. e. Proof that the seismology equipment to be used at the blasting site has been calibrated and certified within one year of the proposed blasting. f. Evidence of the notification required by this article, sent by U.S. mail, to owners of property and utility lines located within 1,500 feet of the blast site. The required evidence shall include a copy of the written notification and a list of names and addresses of those notified. Said written notification shall contain the following information: 1. Notice of intent to blast; 2. Name of the blasting contractor; 3. Estimated duration of blasting operations and the general location of the blast site, with a copy of the map included with the notice; 4. Name of the insurance agency providing the blasting contractor's liability insurance coverage and the agency's contact information; and 5. The date, time, and location of the informational meeting with property owners and/or utility company representatives. g. Evidence of the notification required by this article, sent by certified mail, return receipt requested, not less than 15 days before blasting commences to owners of property and utility lines located within 500 feet of the blast site. The required evidence shall include a copy of the written notification and a list of names and addresses of those notified. Said written notification shall contain the following information and/or statements: 1. Notice of intent to blast; 2. Name of blasting contractor; 3. Estimated duration of blasting operations and the general location of the blast site, with a copy of the map included with the notice; 4. Name of the insurance agency providing the blasting contractor's liability insurance coverage and the agency's contact information; 5. The date, time, and location of the informational meeting with owners of property located within 500 feet of the blast site and/or with representatives of utility companies with utility lines located within 500 feet of the blast site; 6. Name of the company performing the pre-blast surveys; 7. Contact information for the company performing the pre-blast surveys; 8. An offer to permit representatives of notified utility companies to be present during blasting operations; 9. A statement advising the utility company that if it fails within ten days of receipt of the notice to object to the intent to blast, or to request additional time to review the plans, any objections are deemed waived; and 10. A statement advising the utility company that the utility company is responsible for identifying the need for, and requesting, a pre-blast survey of utility company structures. h. A copy of a pre-blast survey log which contains a list of properties with structures and/or utility lines eligible for pre-blast surveys, and a list of properties with structures and/or utility lines which received pre-blast surveys. i. The name, address, and telephone number of the qualified blasting expert who shall review and analyze the blasting plan, including the items listed below, anytime blasting occurs within 500 feet of any structure or utility line. The qualified blasting expert shall be experienced in blasting operations. The blasting expert shall be approved by, and report to, the Lawrence-Douglas County Fire Medical fire marshal. Said blasting expert shall be independent of the blasting contractor and shall be compensated by the applicant. The blasting expert shall provide the Lawrence-Douglas County Fire Medical fire marshal with proof of general liability insurance in an amount consistent with industry standards. The blasting expert shall review and analyze the following: 1. Pre-blast survey records to confirm the pre-blast surveys were performed in accordance with this article; 2. The notice of the informational meeting for property and utility line owners, to verify it was sent in accordance with this article; 3. Proposed location and time of the blasts; 4. Credentials of the certified blaster designated to be in charge of the blasting operation; 5. Type of material to be blasted; 6. Number of proposed holes to be bored and the spacing thereof; 7. Proposed diameter of, and proposed depth of, holes; 8. Type and amount of explosives to be used; 9. Amount of explosives per delay of eight milliseconds or greater; 10. Proposed method of firing and proposed type of circuit to be used; 11. Verification that no blasting shall occur within 100 feet of any structure or utility line, unless a written consent from the owners of the structure or utility line is on file with the fire marshal, and the planned blasting conforms with the limits recommended by the U.S. Bureau of Mines Table of Scaled Distances (NFPA 495); 12. Whether or not mats or other precautions will be used; 13. Type of proposed detonators and delay periods; 14. Type and height of proposed stemming; 15. Proposed locations of seismology equipment during blasting operations and verification of the equipment's calibration/certification within one year of the proposed blasts; 16. Verification of notice to utility companies; and 17. Subsurface analysis of the site. j. Upon completion of the review and analysis required by subsection (c)(1)a of this section, the blasting expert shall provide a written statement to the Lawrence-Douglas County Fire Medical fire marshal certifying that the proposed blasting operation does or does not meet the city Code. k. The applicant shall offer pre-blast surveys to residents or owners of structures and utility lines located within 500 feet of the blasting site. The pre-blast surveys shall conform to the requirements of this article. The pre-blast surveys shall be completed before the initiation of blasting may occur, unless permission to conduct a pre-blast survey has been denied or contact with the owner or occupant of the structure or utility line could not be made after due diligence on the part of the pre-blast survey company representative to make such contact. (2) The applicant shall maintain and provide proof of liability insurance coverage for the purpose of payment of damages to persons or property which arise from, or are caused by, the blasting operations. The policy shall provide for the following minimum coverage: a. Liability insurance to cover injuries or damages to persons or property which might result from blasting operations: 1. General aggregate (or a combination of general liability insurance and an umbrella policy insuring the blasting operations): $5,000,000.00. 2. Each occurrence: $2,000,000.00. b. Automobile liability insurance combined single limit: $1,000,000.00. c. Workers' compensation: statutory coverage. (3) The applicant shall pay an application fee as provided in the city fee schedule.

(Code 2018, § 8-603; Ord. No. 7925)

Ask a question about Lawrence law

Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.