Sec. 8-607. - Blasting operations.

(a) Use and handling. (1) Distance from structures. There shall be no blasting within 100 feet of any structure or utility line unless the owner of the structures and/or utility lines consent in writing, and the blasting conforms with the limits recommended by the U.S. Bureau of Mines Table of Scaled Distances. (2) General. Blasting operations shall be conducted only by approved, competent operators familiar with the required safety precautions and the hazards involved. Blasting operations shall be performed in accordance with the instructions of the manufacturer of the explosive materials being used. (3) Blasting in close proximity. When blasting is done in close proximity to a structure, railway or highway, or any other installation, precautions shall be taken to minimize earth vibrations and air blast effects. Blasting mats or other protective means shall be used to prevent fragments from being thrown. (4) Restricted hours. Blasting operations shall only be conducted during daylight hours. (5) Personnel. Persons in charge of blasting shall not be under the influence of alcohol or drugs which impair sensory or motor skills, shall be at least 21 years of age, and shall demonstrate knowledge of all safety precautions related to the storage, handling or use of explosives or explosive materials. Persons 18 years of age or older are allowed to use and handle explosive materials under the direct supervision of a person who possesses a valid permit to blast explosives issued by the state fire marshal. (6) Open flames and lights. Smoking, matches, flame-producing devices, open flames, firearms and firearms cartridges shall not be permitted inside of or within the blast site. (7) Blasting safeguards. Before a blast is fired, the person in charge shall make certain that surplus explosive materials are in a safe place, that persons and equipment are at a safe distance or under sufficient cover, and that a loud warning signal reasonably calculated to be heard by individuals not less than 100 feet of the blast site has been sounded. (8) Electric detonator precautions. Precautions shall be taken to prevent accidental discharge of electric detonators from currents induced by radar and radio transmitters, lightning, adjacent power lines, dust and snowstorms, or other sources of extraneous electricity. (9) Non-electric detonator precautions. Precautions shall be taken to prevent accidental initiation of non-electric detonators from stray currents induced by lightning or static electricity. (10) Non-sparking tools. Tools used for the opening and closing of packages of explosive materials, other than metal slitters for opening paper, plastic or fiberboard containers, shall be made of non-sparking materials. (11) Disposal of packaging. Empty containers and paper and fiber packaging materials that previously contained explosive materials shall be disposed of or reused in an appropriate manner. (12) Abandonment. Explosive materials shall not be abandoned. (13) Transportation. Explosive materials shall be transported in accordance with this chapter and amendments thereto. (14) Blast records. A record of each blast shall be kept and retained by the applicant for at least five years and shall be available for inspection upon request by the Lawrence-Douglas County Fire Medical fire marshal or owners of property within 500 feet of the blast site or as provided by law. These records shall contain the following minimum data: a. Name of blasting contractor. b. Pre-blast survey records. c. Location and time of blast. d. Name of certified blaster in charge. e. Type of material blasted. f. Number of holes bored and spacing. g. Diameter and depth of holes. h. Type and amount of explosives. i. Amount of explosives per delay of eight milliseconds or greater. j. Method of firing and type of circuit. k. Identification, direction, and distance, in feet, from the nearest blast hole to the nearest building or structure outside the permit area. l. Whether or not mats or other precautions were used. m. Type of detonators and delay periods. n. Type and height of stemming. o. Seismograph and air blast records. (15) Post-blast survey of structure. If during the course of the blasting operation, a complaint is made, or a claim of damage is stated, the applicant shall, with the owner's consent, have the surveyor conduct a post-blast inspection of the structure in question. The surveyor, blasting contractor, and/or insurance agency representative shall investigate each complaint or claim thoroughly using where appropriate the surveyor's written report to compare preexisting damages with those being claimed. (16) Other regulations. Blasting operations shall be conducted in accordance with federal, state and local regulations. (b) Ground vibration and airblasts. (1) Maximum peak particle velocity. The maximum peak particle velocity at the nearest structure or utility line shall not exceed one inch per second in any one of three mutually perpendicular directions, unless the property or utility line owners consents in writing. (2) Ground vibration. Regardless of the distance to nearby structures and utility lines, the blasting operations shall be carried out in such a manner that they will not cause flyrock damage or damage from exceeding air blast or ground vibration limits. (3) Seismographic monitoring. Seismographic monitoring of blasts occurring within 500 feet of any structure or utility line shall be provided by a firm independent of the blasting contractor, approved by the fire prevention division, reporting directly to the Lawrence-Douglas County Fire Medical fire marshal and compensated by the applicant. The seismograph monitoring site shall be located between the nearest structure or utility line and the blast site. Seismographic monitoring of blasts occurring at a distance greater than 500 feet of any structure or utility line shall be provided by the blasting contractor or by a firm engaged by the blasting contractor. (4) Calibration/certification of seismology equipment. All seismology equipment used on the job site, by either the applicant or a third party independent firm shall have been calibrated and certified within the year preceding the blasting operations. (5) Airblasts. Airblasts at the location of any structure shall not exceed the maximum limits specified in Table 10.2.1 of NFPA 495. Table 10.2.1. Airblast Limits Lower Frequency Measuring System [Hz(± three dcb)] | Measurement Level (dcb) 0.1 Hz or lower, flat response* | 134 peak 2 Hz or lower, flat response | 133 peak 6 Hz or lower, flat response | 129 peak C-Weighted, slow response* | 105 peak *Only where approved by the authority having jurisdiction. (c) Notice of new storage site. When a new explosive material storage location, including a temporary jobsite, is established, the applicant shall notify 48 hours in advance, not including Saturdays, Sundays and city holidays, the Lawrence-Douglas County Fire Medical, the city police department, and the county emergency management department of the type, quantity and location of explosive materials at the site. (1) The Lawrence-Douglas County Fire Medical fire marshal is authorized to limit the quantity of explosive materials allowed at any location. (2) The fire marshal is authorized to remove, or cause to be removed or disposed of in an approved manner, at the expense of the applicant, explosives and explosive materials stored, possessed, or used in violation of this article. (3) Storage of explosive materials shall comply with this chapter and amendments thereto. (4) The applicant shall possess a valid permit to store explosives from the state fire marshal's office for the storage site. (d) Posting notification. The applicant shall cause to be posted in a conspicuous location, accessible to the public, a weather protected copy of the site map, a copy of the permit to use or possess explosive materials issued by the division of fire prevention, and copies of the permits to blast explosives issued by the state fire marshal's office for all on-site personnel responsible for blasting operations.

(Code 2018, § 8-607; Ord. No. 7925)

Ask a question about Lawrence law

Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.