For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 9-720 — Section 307 amended

Code of Ordinances of the City of Lawrence, Kansas (Codified through Ordinance No. 10209, enacted April 14, 2026 (Supp. No. 4)) · Lawrence Code of Ordinances § 9-720

Corpus is an independent public-information project, not the official City of Lawrence website. Stable reference: corpuslaw.us/code/1fddd82f-5d07-419e-a84a-66926ab1c8f9

Sec. 9-720. - Section 307 amended.

Section 307 of the 2018 International Property Maintenance Code, in its entirety, is hereby deleted. In its place, the governing body enacts the following: 307.1. Handrails. All buildings and structures shall provide handrails in accordance with the building code under which they were constructed. For buildings and structures constructed during a time when no building code provisions relating to handrails were in effect, the following provision shall apply: 307.1.1. Handrails required. Every exterior and interior flight of stairs having more than four risers shall have a handrail on one side of the stairs. Handrails shall not be less than 30 inches (762 mm) in height or more than 42 inches (1,067 mm) in height measured vertically above the nosing of the tread or above the finished floor of the landing or walking surfaces. 307.2. Guardrails. All buildings and structures shall provide guardrails in accordance with the building Code under which they were constructed. For buildings constructed during a time when no building Code provision relating to guardrails were in effect, the following provision shall apply: 307.2.1. Guardrails required. Every open portion of a landing, balcony, porch, deck, ramp or other walking surface that is more than 30 inches (762 mm) above floor or grade below shall have guardrails. Every open portion of a stair that is greater than 42 inches (1,067 mm) above floor or grade below shall have guardrails. Guardrails shall not be less than 30 inches (762 mm) in height above the floor of a landing, balcony, porch, deck, ramp or other walking surface. 307.2.2. Guardrail spacing. Every open portion of a landing, balcony, porch, deck, ramp or other walking surface that is more than 30 inches (762 mm) inches above the floor or grade below shall have guardrails that contain intermediate rails, balusters or other construction methods that are judged to be safe by the code official. Every open portion of a stair, landing, balcony, porch, deck, ramp or other walking surface that is greater than 42 inches (1,067 mm) above floor or grade below shall have guardrails that contain intermediate rails, balusters or other construction methods that do not allow for the passage of a sphere six inches (153 mm) in diameter. Exceptions: 1. Guardrails shall not be required where exempted by the adopted building code. 2. Where required guardrails, intermediate rails, balusters, or other constructions methods are missing in their entirety for a portion of a stair, landing, balcony, porch, deck, ramp, or other walking surface, the building components shall be installed in accordance with the adopted building code. 2. Guardrails, intermediate rails, balusters, and other construction methods located on an open portion of a stair, landing, balcony, porch, deck, ramp, or other walking surface less than 42 inches (1,067 mm) above floor or grade below may be repaired to original condition if judged to be safe by the code official.

(Code 2018, § 9-620)

Ask a question about Lawrence law

Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.