§ 16.300.1010.6
Code of the City of Overland Park, Kansas · Overland Park Municipal Code, tit. 16, art. 16.300.100, § 16.300.1010.6
Corpus is an independent public-information project, not the official City of Overland Park website. Stable reference: corpuslaw.us/code/395947fd-6612-41f0-8edc-cb87abaa4698
16.300.1010.6
Section 1010.6 of the International Building Code is hereby added to read as follows: 1010.6 Physical security. 1010.6.1 Purpose. The purpose of this section is to establish minimum standards that incorporate physical security to make dwelling units resistant to unlawful entry. 1010.6.1.1 Scope. The provisions of this section shall apply to all new structures and to additions made to existing buildings. 1010.6.2 Doors. Except for vehicular access doors, all exterior doors of residential buildings and attached garages, including the doors leading from the garage area or interior corridor into the building or dwelling unit, shall comply with Sections 1010.6.2.1 through 1010.6.2.5 for the type of door installed. When approved by the code official and after consultation with the City’s Community Policing Unit, doors into individual dwelling units, that are inside of buildings with access controlled exterior doors meeting the requirements of Sections 1010.6.2 through 1010.6.4 and meeting the lighting requirements in Section 1010.6.6, are exempt from the requirements of Section 1010.6. 1010.6.2.1 Wood doors. Where installed, exterior wood doors shall be of solid core construction such as high-density particleboard, solid wood, or wood block core with a minimum thickness of one and three-fourths (1 ¾) inches at any point. Doors with panel inserts shall be solid wood. The panels shall be a minimum of 1 inch thick. The tapered portion of the panel that inserts into the groove of the door shall be a minimum of one-quarter (¼) inch thick. The groove shall be a dado groove or applied molding construction. The groove shall be a minimum of one-half (½) inch in depth. 1010.6.2.2 Steel doors. Where installed, exterior steel doors shall be a minimum thickness of 24 gauge. 1010.6.2.3 Fiberglass doors. Fiberglass doors shall have a minimum skin thickness of one-sixteenth (1/16) inch and have reinforcement material at the location of the deadbolt. 1010.6.2.4 Double doors. Where installed, the inactive leaf of an exterior double door shall be provided with flush bolts having an engagement of not less than 1 inch into the head and threshold of the doorframe. 1010.6.2.5 Sliding doors. Where installed, exterior sliding doors shall comply with all of the following requirements: (1) 1. Sliding door assemblies shall be installed to prevent the removal of the panels and the glazing from the exterior with the installation of shims or screws in the upper track. (2) 2. All sliding glass doors shall be equipped with a secondary locking device consisting of a metal pin or a surface mounted bolt assembly. Metal pins shall be installed at the intersection of the inner and outer panels of the inside door and shall not penetrate the frame’s exterior surface. The surface mounted bolt assembly shall be installed at the base of the door. 1010.6.2.6 Glass doors and associated frame assemblies. Glass doors and glass storefront assemblies shall be constructed using laminated glass extending up to a minimum of 48 inches above the exterior finished grade. The minimum grade of laminate shall be 0.60 PVB interlayer (refer to ASTM E1996). 1010.6.3 Door frames. The exterior door frames shall be installed prior to a final inspection. Door frames shall comply with Sections 1010.6.3.1 through 1010.6.3.3 for the type of assembly installed. 1010.6.3.1 Wood frames. Wood door frames shall comply with all of the following requirements: (1) 1. All exterior door frames shall be set in frame openings constructed of double studding or equivalent construction, including garage doors, but excluding overhead doors. Door frames, including those with sidelights shall be reinforced in accordance with ASTM F476 Grade 40. (2) 2. In wood framing, horizontal blocking shall be placed between studs at the door lock height for 3 stud spaces or equivalent bracing on each side of the door opening. 1010.6.3.2 Steel frames. All exterior door frames shall be constructed of 18 gauge or heavier steel and reinforced at the hinges and strikes. All steel frames shall be anchored to the wall in accordance with manufacturer specifications. Supporting wall structures shall consist of double studding or framing of equivalent strength. Frames shall be installed to eliminate tolerances inside the rough opening. 1010.6.3.3 Door jambs. Door stops on wooden jambs for in-swinging doors shall be of one-piece construction. Jambs for all doors shall be constructed or protected so as to prevent violation of the strike. 1010.6.4 Door hardware. Exterior door hardware shall comply with Sections 1010.6.4.1 through 1010.6.4.6. 1010.6.4.1 Hinges. Hinges for exterior swinging doors shall comply with the following: (1) 1. At least 2 screws, 3 inches in length, penetrating at least 1 inch into the wall structure shall be used. Solid wood fillers or shims shall be used to eliminate any space between the wall structure and door frame behind each hinge. (2) 2. Hinges for out-swinging doors shall be equipped with mechanical interlock to preclude the removal of the door from the exterior. 1010.6.4.2 Strike plates. Exterior door strike plates shall be a minimum of 18 gauge metal with 4 offset screw holes. Strike plates shall be attached to wood with not less than 3 inch screws, which shall have a minimum of 1 inch penetration into the nearest stud. For side lighted units, refer to Section 1010.6.4.6. 1010.6.4.3 Escutcheon plates. All exterior doors shall have escutcheon plates or wrap-around door channels installed around the lock protecting the door’s edge. Exceptions: (1) 1. Single seam steel doors. (2) 2. Glass doors. 1010.6.4.4 Locks. Exterior doors shall be provided with a locking device complying with all of the following: Single Cylinder Deadbolt shall have a minimum projection of one inch. The deadbolt shall penetrate at least three-fourths (¾) inch into the strike receiving the projected bolt. The cylinder shall have a twist- resistant, tapered hardened steel cylinder guard. The cylinder shall have a minimum of 5 pin tumblers, shall be connected to the inner portion of the lock by solid metal connecting screws at least one-fourth (¼) inch in diameter and two and one-fourth (2 ¼) inches in length. Bolt assembly (bolt housing) unit shall be of single piece construction. All deadbolts shall meet ANSI grade 2 specifications or BHMA Security Grade “B”. 1010.6.4.5 Entry vision and glazing. All main or front entry doors to dwelling units shall be arranged so that the occupant has a view of the area immediately outside the door without opening the door. The view may be provided by a door viewer having a field of view of not less than 160 degrees, through windows, or through view ports. 1010.6.4.6 Side lighted entry doors. Side light door units shall have framing of double stud construction or equivalent construction complying with Sections 1010.6.3.1, 1010.6.3.2 and 1010.6.3.3. The door frame that separates the door opening from the side light, whether on the latch side or the hinge side, shall be double stud construction or equivalent construction complying with Sections 1010.6.3.1 and 1010.6.3.2. Double stud construction or construction of equivalent strength shall exist between the glazing unit of the side light and wall structure of the dwelling. 1010.6.5 Street numbers. Street numbers shall comply with Section 505 of the International Fire Code. 1010.6.6 Exterior lighting. Exterior lighting shall comply with Sections 1010.6.6.1 through 1010.6.6.2. 1010.6.6.1 Front and street side exterior lighting. All front and street side door entrances should be protected with a minimum of one light outlet having a minimum of 800 lumens of lighting, installed so that the light source is not readily accessible. 1010.6.6.2 Rear exterior lighting. Buildings with windows or doors less than 8 feet above a walking surface on the rear side of the house shall be equipped with a minimum of one light outlet having 1600 lumens lighting and shall be of the flood light type. Those fixtures placed less than 8 feet above a walking surface shall be fixtures manufactured such that the light source is not readily accessible. 1010.6.7 Alternate materials and methods of construction. The provisions of this section are not intended to prevent the use of any material or method of construction not specifically prescribed by this section, provided any such alternate has been approved by the enforcing authority, nor is it the intention of this section to exclude any sound method of structural design or analysis not specifically provided for in this section. The materials, methods of construction and structural design limitations provided for in this section shall be used unless the enforcing authority grants an exception. The enforcing authority is authorized to approve any such alternative provided they find the proposed design, materials and methods of work to be at least equivalent to those prescribed in this section in quality, strength, effectiveness, burglary resistance, durability and safety. (History: Ord. No. BC-3499 §31, 2026; Ord. No. BC-3286 §30, 2020) Effective on: 1/1/1901
Ask a question about Overland Park law
Corpus searches the Overland Park sections it holds and shows the ones that match, with their citations. Free, no sign-in.