16.310.E3901.4.3
Section E3901.4.3 of the 2024 International Residential Code is hereby amended to read as follows: E3901.4.3 Receptacle outlet location. Receptacle outlets shall be located in one or more of the following: (1) 1. On or above, but not more than 20 inches (508 mm) above, the countertop or work surface. (2) 2. In countertop or work surfaces, receptacle outlet assemblies listed for use in countertops or work surfaces shall be permitted to be installed in countertops or work surfaces. (3) 3. Below countertop or work surfaces, not more than 12 inches below the countertop or work surface. Receptacles installed below a countertop or work surface shall not be located where the countertop or work surface extends more than 6 inches beyond its support base. (History: Ord. No. BC-3513, §46, 2026) Effective on: 1/1/1901