§ 16.370.C105.2

Code of the City of Overland Park, Kansas · Overland Park Municipal Code, tit. 16, art. 16.370, § 16.370.C105.2

Corpus is an independent public-information project, not the official City of Overland Park website. Stable reference: corpuslaw.us/code/bdc341d7-d74e-4222-9658-58ae73f0b7b8

16.370.C105.2

Section C105.2 of the International Energy Conservation Code is hereby amended to read as follows: C105.2 Information on construction documents. Construction documents shall be drawn to scale on suitable material. Electronic media documents are permitted to be submitted where approved by the code official. Construction documents shall be of sufficient clarity to indicate the location, nature and extent of the work proposed, and show in sufficient detail pertinent data and features of the building, systems and equipment as herein governed. Details shall include, but are not limited to, the following as applicable: (1) 1. Energy compliance path. (2) 2. Insulation materials and their R-values. (3) 3. Fenestration U-factors and solar heat gain coefficients (SHGC). (4) 4. Area-weighted U-factor and solar heat gain coefficient (SHGC) calculations. (5) 5. Air barrier and air sealing details, including the location of the air barrier. (6) 6. Thermal bridges as identified in Section C402.7. (7) 7. Mechanical system design criteria. (8) 8. Mechanical and service water-heating systems and equipment types, sizes and efficiencies. (9) 9. Economizer description. (10) 10. Equipment and system controls. (11) 11. Fan motor horsepower (hp) and controls. (12) 12. Duct sealing, duct and pipe insulation and location. (13) 13. Lighting fixture schedule with wattage and control narrative. (14) 14. Location of daylight zones on floor plans. (15) 15. Location of pathways for routing of raceways or cable from the on-site renewable energy system to the electrical distribution equipment. (16) 16. Location reserved for inverters, metering equipment and energy storage systems (ESS), and a pathway reserved for routing of raceways or conduit from the renewable energy system to the point of interconnection with the electrical service and the ESS. (17) 17. Location and layout of a designated area for ESS. (18) 18. Rated energy capacity and rated power capacity of the installed or planned ESS. (19) 19. The additional energy requirements chosen from Section C406. C105.2.1 Building thermal envelope depiction. The building thermal envelope shall be represented on the construction drawings. (History: Ord. No. BC-3499, §165, 2026) Effective on: 1/1/1901

Ask a question about Overland Park law

Corpus searches the Overland Park sections it holds and shows the ones that match, with their citations. Free, no sign-in.