§ 41-70.3 — Regulated cross connections

Salina Code, City of Salina, Kansas (Codified through Ordinance No. 26-11299 adopted August 24, 2026. (Supp. No. 19)) · Salina Municipal Code § 41-70.3

Corpus is an independent public-information project, not the official City of Salina website. Stable reference: corpuslaw.us/code/dceae4bf-1af5-444c-b8c0-829134c82a59

Sec. 41-70.3. - Regulated cross connections.

Cross connections made in the following installations shall be regulated in the following manner: (1) Boilers. Potable water connections to boiler feed water systems in which boiler water conditioning chemicals are or can be introduced shall be made through an air gap or through a reduced pressure zone backflow preventer located in the potable water line before the point where such chemicals may be introduced. (2) Refrigeration unit condensers and cooling jackets. Except when potable water provided for a refrigeration condenser or cooling jacket is entirely outside the piping or tank containing a toxic refrigerant, the inlet connection shall be provided with an approved backflow preventer. Heat exchangers used to heat water for potable use shall be of the double wall type. (3) Cross connections not subject to backpressure. Where a water cross connection is not subject to back pressure, a vacuum breaker shall be installed on the discharge side of the last valve on the line serving the fixture or equipment. A list of some conditions requiring protective devices of this kind are given in the following table: Partial list of cross connections not subject to back pressure. a. Aspirators and ejectors; b. Commercial dish washing machine; c. Commercial laundry machine; d. Dental units; e. Garbage can cleaning machines; f. Flush tanks; g. Hose bibs; h. Hose outlets; i. Steam tables; j. Tank and vats. (4) Cross connections subject to backpressure. Where a potable water cross connection is made to a line, fixture, tank, vat, pump, or other equipment with a hazard of backflow where the water cross connection is subject to backpressure, an air gap shall be installed. Where an air gap cannot be installed, the utilities department may require the use of an approved reduced pressure zone backflow preventer. A partial list of such connections is shown in the following table: Partial list of cross connections subject to back pressure: a. Chemical lines; b. Dock water outlets; c. Fire sprinkler systems; d. Hose bibs (where hose use is above free water surface); e. Industrial process water lines; f. Pressure tanks; g. Pumps; h. Steam lines; i. Swimming pools; j. Tanks and vats, bottom inlets. (5) Other cross connections. Connection to the public potable water supply system for the following is prohibited unless properly protected by the appropriate backflow prevention device. a. Bidets; b. Operating, dissecting, embalming, and mortuary tables or similar equipment; in such installations the hose used for water supply shall terminate at least twelve (12) inches away from every point of the table or attachments; c. Pumps for nonpotable substances; priming only through an air gap; d. Building drains, sewers, or vent systems; e. Commercial buildings or industrial plants manufacturing or otherwise using polluting or contaminating substances; f. Underground irrigation systems; g. Any fixture of similar hazard.

(Ord. No. 93-9571, § 1, 6-7-93; Ord. No. 03-10145, § 1, 6-2-03)

Ask a question about Salina law

Corpus searches the Salina sections it holds and shows the ones that match, with their citations. Free, no sign-in.