§ 42-441 — Specific standards
Salina Code, City of Salina, Kansas (Codified through Ordinance No. 26-11299 adopted August 24, 2026. (Supp. No. 19)) · Salina Municipal Code § 42-441
Corpus is an independent public-information project, not the official City of Salina website. Stable reference: corpuslaw.us/code/7118e465-5c4a-4e26-90fb-994490e84698
Sec. 42-441. - Specific standards.
In all areas identified as numbered and unnumbered A zones, AE, and AH zones, where base flood elevation data have been provided, as set forth in subsection 42-440(b), the following provisions are required: (1) Residential construction. New construction or substantial improvement of any residential structures, including manufactured homes, shall have the lowest floor, including basement, elevated a minimum of one (1) foot above base flood elevation, unless the lowest floor meets the requirements of a below-grade crawlspace as provided in subsection 42-441(4). Mechanical and HVAC equipment servicing the building must be elevated or flood protected to same level as the lowest floor. The elevation of the lowest floor shall be certified by a licensed land surveyor or professional engineer. (2) Non-residential construction. New construction or substantial improvement of any commercial, industrial, or other non-residential structures, including manufactured homes, shall have the lowest floor, including basement, elevated a minimum of one (1) foot above the base flood elevation or, together with attendant utility and sanitary facilities, be floodproofed so that below one (1) foot above the base flood elevation the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. Mechanical and HVAC equipment servicing the building must be elevated or flood protected to same level as the lowest floor. A registered professional engineer or architect shall verify that the standards of this subsection are satisfied. The elevation of the lowest floor shall be certified by a licensed land surveyor or professional engineer. Such certification shall be provided to the floodplain administrator as set forth in subsection 42-438(7)—(9). (3) Enclosures below lowest floor. New construction and substantial improvements of fully enclosed areas below lowest floor used solely for parking of vehicles, building access, or storage in an area other than a basement and that are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of flood waters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: a. A minimum of two (2) openings having a total net area of not less than one (1) square inch for every square foot of enclosed area subject to flooding shall be provided; and b. The bottom of all openings shall be no higher than one (1) foot above grade. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of flood waters. (4) Crawl spaces and below-grade crawl spaces. a. The velocity of floodwaters at the site shall not exceed five (5) feet per second for any crawlspace, as calculated by a registered professional engineer. For velocities in excess of five (5) feet per second, other foundation types should be used or the design must be reviewed and approved by a registered architect or professional engineer. b. The building must be designed and adequately anchored to resist flotation, collapse, and lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. c. The crawlspace is an enclosed area below the BFE and, as such, must have openings that equalize hydrostatic pressures by allowing for the automatic entry and exit of floodwaters. The bottom of each flood vent opening can be no more than one (1) foot above the lowest adjacent grade. d. Portions of the building below one (1) foot above the BFE must be constructed with materials resistant to flood damage. This includes the foundation walls of the crawlspace used to elevate the building, any joists, insulation, or other materials that extend below the BFE. e. Any building utility systems, including ductwork, within the crawlspace must be elevated one (1) foot above BFE or designed so that floodwaters cannot enter or accumulate within the system components during flood conditions. The elevation shall be certified by a licensed land surveyor or professional engineer. f. The interior grade of a crawlspace below the BFE must not be more than two (2) feet below the lowest adjacent exterior grade (LAG). g. The height of the below-grade crawlspace, measured from the interior grade of the crawlspace to the top of the crawlspace foundation wall must not exceed four (4) feet at any point. h. There must be an adequate drainage system that removes floodwaters from the interior area of the crawlspace. The enclosed area should be drained within a reasonable time after a flood event. The type of drainage system will vary because of the site gradient and other drainage characteristics, such as soil types. Possible options include natural drainage through porous, well-drained soils and drainage systems such as perforated pipes, drainage tiles, or gravel or crushed stone drainage by gravity or mechanical means.
(Ord. No. 18-10930, § 1, 4-9-18)
Ask a question about Salina law
Corpus searches the Salina sections it holds and shows the ones that match, with their citations. Free, no sign-in.