For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 42-442 — Manufactured homes

Salina Code, City of Salina, Kansas (Codified through Ordinance No. 26-11299 adopted August 24, 2026. (Supp. No. 19)) · Salina Municipal Code § 42-442

Corpus is an independent public-information project, not the official City of Salina website. Stable reference: corpuslaw.us/code/8bd33c1b-44d6-4991-8a2e-f90801ae81e1

Sec. 42-442. - Manufactured homes.

(a) All manufactured homes to be placed within all unnumbered and numbered A zones, AE, and AH zones, on the city's FIRM shall be required to be installed using methods and practices that minimize flood damage. For the purposes of this requirement, manufactured homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. (b) Manufactured homes that are placed or substantially improved within unnumbered or numbered A zones, AE, and AH zones, on the city's FIRM: (1) Located outside of a manufactured home park or subdivision; (2) Located in a new manufactured home park or subdivision; (3) Located in an expansion to an existing manufactured home park or subdivision; or (4) Located in an existing manufactured home park or subdivision on which a manufactured home has incurred substantial damage as the result of a flood, must be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated a minimum of one (1) foot above the base flood elevation and be securely attached to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. Mechanical and HVAC equipment servicing the building must be elevated or flood protected to the same level as the lowest floor. The elevation of the lowest floor shall be certified by a licensed land surveyor or professional engineer. (c) Manufactured homes to be placed or substantially improved on sites in an existing manufactured home park or subdivision within any unnumbered and numbered A zones, AE and AH zones, on the city's FIRM, that are not subject to the provisions of subsection 42-442(b) of this article must be elevated so that either: (1) The lowest floor of the manufactured home is a minimum of one (1) foot above the base flood level; or (2) The manufactured home chassis is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than thirty-six (36) inches in height above grade and securely attached to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. Mechanical and HVAC equipment servicing the building must be elevated or flood protected to the same level as the lowest floor. The elevation of the lowest floor shall be certified by a licensed land surveyor or professional engineer.

(Ord. No. 18-10930, § 1, 4-9-18)

Ask a question about Salina law

Corpus searches the Salina sections it holds and shows the ones that match, with their citations. Free, no sign-in.