Sec. 8-1-2-R404.1.7. - Amendment to Section R404.1.7 of the IRC.

Section R404.1.7 of the IRC is amended to read as follows: Sec. R404.1.7 Backfill placement. Backfill shall not be placed against the wall until one of following conditions has been met: 1. The wall has cured for a minimum of 7 days or, 2. The wall has sufficient strength and has been anchored to the floor above or, 3. The wall has been sufficiently braced to prevent damage by the backfill. Exception: Bracing is not required for walls supporting less than 4 feet (1219 mm) of unbalanced backfill. Compaction of backfill shall not be initiated until the wall has been anchored to the floor above or provided with temporary bracing. Exception: Backfill against contiguous basement walls beneath garage floors may be compacted before the walls have been anchored to the floor above provided that the walls have cured for a minimum of 7 days.

(Ord. No. 25-11267, § 1, 12-8-25)