Sec. 16.24.025. - General criteria—Design and approval.
Grease interceptors shall be constructed in accordance with the design(s) approved by the director and shall have a minimum of two compartments with fittings designed for grease retention. Other grease removal devices or technologies not meeting the gravity grease interceptor definition in Section 16.24.010(j) shall be subject to the written approval of the director. Such approval shall be based on demonstrated removal efficiencies of the proposed technology. Hydro mechanical grease interceptors, also known as "Under the sink" grease interceptors, shall not be approved. Access manholes, with a minimum diameter of 24 inches, shall be provided over each chamber and sanitary tee. The access manholes shall extend at least to finished grade and shall be designed and maintained to prevent water inflow or infiltration. The manholes shall also have readily removable traffic bearing covers to facilitate inspection, grease removal, and wastewater sampling activities. There shall be an adequate number of access points for cleaning and inspecting all areas of the grease interceptor. Manhole covers shall be gas tight in construction. In areas where additional weight loads may exist, the grease interceptor shall be designed to have adequate load-bearing capacity. Permission to use an automatic grease removal device (AGRD) as described in Section 16.24.010(a) must be approved by the director. Prior to using an automatic grease removal device, the permit holder shall submit an Application for Variance to the Pretreatment Administrator. Installation of the AGRD is subject to the approval of the director after examining the information contained in the Application for Variance. The device may be permitted in conjunction with, or in lieu of, a gravity grease interceptor. A solids separator or strainer of sufficient size shall be installed in-line prior to the wastewater entering the automated grease removal device or as an integral part of the device. All manufacturer installation guidelines must be adhered to.
(Ord. No. 47-553, § 3, 8-24-2007; Ord. No. 51-064, § 1, 7-23-19)
Ask a question about Wichita law
Corpus searches the Wichita sections it holds and shows the ones that match, with their citations. Free, no sign-in.