§ 16.24.060 — Grease interceptor maintenance
The Code of the City of Wichita, Kansas (Supp. No. 36, Update 1: codified through Ordinance No. 53-088, adopted July 28, 2026) · Wichita City Code § 16.24.060
Corpus is an independent public-information project, not the official City of Wichita website. Stable reference: corpuslaw.us/code/5d00ae96-da1f-43d2-bd21-536d8c770f8b
Sec. 16.24.060. - Grease interceptor maintenance.
(a) Pumping. All grease interceptors shall be maintained by the user at the user's expense. Maintenance shall include the complete removal of all contents, including floating materials, wastewater, and bottom sludge and solids. Decanting or discharging of removed waste back into the interceptor from which the waste was removed or any other grease interceptor, for the purpose of reducing the volume to be disposed, is prohibited. (b) Pumping Frequency. Grease interceptors must be pumped out completely a minimum of once every 90 days, or more frequently as needed, to prevent carryover of grease into the sanitary sewer collection system, unless it can be demonstrated to the director that the pumping frequency can be extended past the three-month period. If the owner/operator wishes to extend the pumping period of the interceptor past 90 days, the facility owner/operator must complete a variance to the grease interceptor maintenance schedule. A variance request fee of not less than $50.00 may apply to recover the costs the city may incur for the variance study. (c) Disposal of Grease Interceptor Pumpage. All waste removed from each grease interceptor must be disposed of at a facility permitted by the city to receive such waste in accordance with the provisions of this chapter. In no way shall the pumpage be returned to any private or public portion of the sanitary sewer collection system or the sewage treatment plants, without prior written approval from the director. (d) Additives. Any additive(s) placed into the grease interceptor or building discharge line system on a constant, regular, or scheduled basis shall be reported to the director. Such additives shall include, but not be limited to, commercially available bacteria or other additives designed to absorb, purge, consume, treat or otherwise eliminate grease and oils. Additives containing enzymes are prohibited. The use of additives shall in no way be considered as a substitution to the maintenance procedures required herein. (e) Physical integrity. All grease interceptors shall be maintained in operable condition and to meet the criteria described in Section 16.24.025 at all times. The integrity of the baffle wall separating the two compartments shall be maintained; rebar shall not be exposed, and grease interceptors with leaks or holes shall be repaired or replaced at the discretion of the director.
(Ord. No. 47-553, § 7, 8-24-2007; Ord. No. 51-064, § 1, 7-23-19)
Ask a question about Wichita law
Corpus searches the Wichita sections it holds and shows the ones that match, with their citations. Free, no sign-in.
