For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16-15 — Commercial access standards

Code of Ordinances, Lexington-Fayette Urban County Government, Kentucky (Republication: codified through Ordinance No. 048-2025, adopted June 26, 2025 (online July 17, 2026)) · Lexington-Fayette Zoning Ordinance § 16-15

Corpus is an independent public-information project, not the official City of Lexington-Fayette urban county website. Stable reference: corpuslaw.us/code/94cd463a-3fff-46af-acba-e111a688bc6f

Sec. 16-15 - Commercial access standards.

Commercial access to a property shall be governed by the following standards and in concert with the adopted Land Subdivision Regulations. Commercial access shall defined as access for the following land uses: multi-family residential; professional services, and banks; institutional uses; schools for academic instruction; businesses for retail sales and eating and drinking establishments; places of religious assembly; commercial parking lots or structures; indoor or outdoor recreation and athletic facilities; hotels of any type; nursing homes, personal care facilities, rehabilitation homes and assisted living facilities; community centers and private clubs; light and heavy industrial; warehouses and storage; and other businesses not specifically identified above. Proposed additional or new commercial entrances shall be aligned with existing curb cuts or existing street features on the opposite side of the street. If entrance locations cannot align, then the proposed commercial entrance shall be a minimum distance away from any other entrance based upon the following: Posted Roadway Speed | Distance Between Commercial Entrances 25 MPH | 100 feet 35 MPH | 150 feet 45 MPH or greater | 200 feet Proposed commercial entrances, shall conform to LFUCG Standard Drawing 307-2 and must meet all Fire Code or LFUCG Division of Fire standards. Driveway width, apron flare and curb radius must meet all Fire Code or LFUCG Division of Fire standards. A minimum fifteen (15) foot curb radius shall be provided for commercial entrances, shared access points and for any entrance from an arterial street. A maximum curb radius of thirty-five (35) feet shall be provided and must be supported by tracking path simulation (e.g. AutoTURN). Entrance spacing along frontage roads shall meet local road access spacing, with a maximum of two (2) access points. Proposed commercial entrances shall be a minimum of one hundred (100) feet from any at-grade railroad crossing right-of-way. Where a median exists in the right-of-way, entrances shall be aligned with median openings. Appropriate storage and taper lengths, pavement markings (including raised pavement markings) for left turn lanes and monolithic median noses shall comply with design standards established by the Traffic Engineering Manual and LFUCG Standard Drawings. No parking spaces shall be permitted to back directly into a public or private street right-of-way. Existing parking lots shall be revised to meet current standards when there is a zone change or addition made to a principal structure of more than thirty percent (30%) of the floor area. When a site is redeveloped, existing entrances shall comply with LFUCG Standard Drawing 307 for entrance apron design and width. Commercial entrances shall be located a minimum of three (3) feet from the property line or more to allow the corresponding apron flare to remain inside the projected property line and be in compliance with LFUCG Standard Drawing 307-1 or 307-2. Existing damage or damage caused during construction activity to existing right-of-way shall be repaired or replaced in concert with permitted construction activities, per Article 5 of the Zoning Ordinance. Gated primary entrances for a private street shall be prohibited. Gates shall meet the performance and operation guidelines of the Division of Fire and Emergency Services. Gated access points for "exit only" or "emergency access only" shall be located a minimum of thirty (30) feet from the curb to ensure vehicles can see the gate before entering. A "do not enter" sign shall be posted on the gate. Any proposed modification to existing LFUCG or KYTC signaling equipment must be reviewed and approved by the Division of Traffic Engineering. Grade changes adjacent to existing LFUCG signaling equipment will require replacement to current LFUCG Traffic Engineering Standards. (Ord. No. 036-2025, § 21, 6-12-2025)

Ask a question about Lexington-Fayette urban county law

Corpus searches the Lexington-Fayette urban county sections it holds and shows the ones that match, with their citations. Free, no sign-in.