§ 16-8 — Special access, surface, and location requirements for garages, parking lots, automobile service stations, and vehicle sales lots

Code of Ordinances, Lexington-Fayette Urban County Government, Kentucky (Republication: codified through Ordinance No. 048-2025, adopted June 26, 2025 (online July 17, 2026)) · Lexington-Fayette Zoning Ordinance § 16-8

Corpus is an independent public-information project, not the official City of Lexington-Fayette urban county website. Stable reference: corpuslaw.us/code/bdb129f4-2db9-47b2-97d0-16eaa6c6080e

Sec. 16-8 - Special access, surface, and location requirements for garages, parking lots, automobile service stations, and vehicle sales lots.

Required Distance Between Service Stations/Garages/Automobile Repair Shops/Automobile and Vehicle Refueling Stations and Residential Zones and/or Institutional Uses. No building, structure or premises intended or designed to be used as a community garage; an automobile repair shop; a service station; an automobile and vehicle refueling station or a parking lot or structure, whether a principal or a conditional use on a property, shall be used, erected or altered, which has an entrance or exit for vehicles in the same block front and within two hundred (200) feet of the property boundary of any school; public playground; place of religious assembly; hospital; public library; convalescent home, nursing home or personal care facility or orphanage. No such entrance or exit, except for a community garage, shall be located within twenty (20) feet of any residential zone; nor shall any structure used for an automobile repair shop or service station, or any part of a parking lot or structure, be located within one hundred (100) feet of any property boundary line of any of the aforesaid public or institutional uses. The term "parking lot," as used herein, does not include off-street parking areas for the public or institutional uses listed above. Required Distance Between Gasoline/Oil Dispensing Facilities and Residential Zones/Uses. No gasoline pump, oil draining pit, or similar appliance for any purpose shall be located within fifteen (15) feet of any right-of-way line, or within fifty (50) feet of a residential zone, except where such a pump, pit or appliance is within a completely enclosed building and distant at least fifteen (15) feet from any vehicular entrance or exit of such building. Notwithstanding the above provision, no gasoline pump, oil draining pit, or similar appliance for any purpose shall be located within sixty-five (65) feet of a single-family residential zone or within sixty-five (65) feet of a single-family detached residential unit located in any residential zone. However, such 65-foot dimension shall not be applicable to the renovation, reconstruction, redevelopment, or construction of such a service station upon a tract used by such a facility within twelve (12) months prior to the application for a building permit. Except for gasoline service stations, no gasoline pump shall be permitted as an accessory use for another activity unless a site plan showing the following is submitted to, and approved by, the Division of Planning. A safe traffic flow pattern shall exist at all times for vehicles to be serviced with gas, including a safe entrance and exit to the service area, and a traffic flow lane not impeded by parked vehicles or other objects. A safe traffic pattern shall exist for pedestrians to ensure that pedestrian flow for other purposes is not routed by the gasoline pumps, thereby exposing such pedestrians to unnecessary hazards. The gasoline pumps shall be operated only by employees of the activity; or if others are permitted to operate them, the facility must comply with Chapter 28 of the Kentucky Fire Prevention Code, specifically Section F-2803.8.2 and Section F-2803.8.2.3. Required Distances Between Automobile and Vehicle Refueling Stations Dispensing Compressed Natural Gas and/or Liquid Natural Gas and Other Uses. In addition to the requirements of this section (above), no stationary dispensing equipment for compressed natural gas or liquid natural gas associated with an automobile and vehicle refueling station may be located within: Ten (10) feet of any sidewalk, walkway, parking lot or property line; Fifteen (15) feet of any electrical source or any overhead electric utility line; Fifty (50) feet of a right-of-way line, a building on another lot, or the nearest rail of any railroad line; Sixty-five (65) feet of a residential zone; and Not less than fifty (50) feet of a fire hydrant. Requirements for Vehicle Sales Lots. Every parcel of land hereafter used as an automobile, truck, mobile home, boat, trailer, or camper sales lot, or as an automobile service station shall be subject to the requirements of this Zoning Ordinance concerning surfacing, lighting, landscaping and screening, and minimum yards and setbacks; and shall be considered, in the application thereof, as the equivalent of a parking area for more than five (5) vehicles, regardless of its size. Community Garages as Conditional Uses. Community garages permitted as a conditional use in a R-3 and R-4 zone shall not be within eighty (80) feet of any right-of-way line or in a R-3 zone be within twenty-five (25) feet of any other lot line; or in a R-4 zone be within twenty (20) feet of any lot line, except the rear lot line of an adjoining Professional Office, Business or Industrial Zone. (Ord. No. 113-2022, § 11, 10-27-2022)

Ask a question about Lexington-Fayette urban county law

Corpus searches the Lexington-Fayette urban county sections it holds and shows the ones that match, with their citations. Free, no sign-in.