§ 18-5 — Provisions for flood hazard reduction
Municipal Code of the City of Owensboro, Kentucky (Codified through Ordinance No. 13-2026, adopted June 16, 2026. (Supp. No. 54, Update 2)) · Owensboro Municipal Code, App. F, art. XVIII, § 18-5
Corpus is an independent public-information project, not the official City of Owensboro website. Stable reference: corpuslaw.us/code/9372cbd6-d975-4165-bebe-1642241d30b7
18-5. - Provisions for flood hazard reduction.
18-5(a) General Standards. In all areas of special flood hazard, the following provisions are required: (1) All new construction and substantial improvements shall be adequately anchored to prevent flotation, collapse or lateral movement of the structure, resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. (2) Manufactured homes shall be anchored to prevent flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This standard shall be in addition to and consistent with applicable state requirements for resisting wind forces, other acceptable installation standards and acceptable similarity appearance standards. (3) All new construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage. (4) New construction and substantial improvements shall be constructed by methods and practices that minimize flood damage. (5) Electrical, heating, ventilation, plumbing, air conditioning equipment, and other service facilities shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding; and if within Zones AH or AO, so that there are adequate drainage paths around structures on slopes to guide flood waters around and away from proposed structures. (6) New and replacement water supply systems shall be designed to minimize or eliminate infiltration of flood waters into the system. (7) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of flood waters into the systems and discharges from the systems into flood waters. (8) On-site waste disposal systems shall be located and constructed to avoid impairment to them or contamination from them during flooding. (9) Any alteration, repair, reconstruction, or improvements to a structure, which is not in compliance with the provisions of this article, shall meet the requirements of "new construction" as contained in this article, and shall be undertaken only if said nonconformity is not furthered, extended, or replaced. 18-5(b) Specific Standards. In all areas of special flood hazard where base flood elevation data have been provided as set forth in Subsection 18-3(b) or Subsection 18-4(c)(9), the following provisions are required. (1) Residential Construction. New construction or substantial improvement of any residential structure (or manufactured home) shall have the lowest floor, including basement, and mechanical equipment elevated no lower than one (1) foot or greater above the base flood elevation. Ductwork shall be installed above the ceiling unless the finish floor elevation is a minimum of two (2) feet above the base flood elevation and a minimum of two (2) feet above the finish grade. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movements of flood waters shall be provided in accordance with standards of Section 18-5(b)(3). (a) In an AO Zone, new construction or substantial improvement shall be elevated above the highest adjacent grade to a height equal to or exceeding the depth number specified in feet on the FIRM, or elevated at least two feet above the highest adjacent grade if no depth number is specified. (b) In an A Zone, where no technical data has been produced by the Federal Emergency Management Agency, new construction or substantial improvement shall be elevated one (1) foot above the base flood elevation, as determined by this community. The Floodplain Administrator will determine the method by which base flood elevations are determined. Methods include but are not limited to detailed hydrologic and hydraulic analyses, use of existing data available from other sources, use of historical data, best supportable and reasonable judgment in the event no data can be produced. Title 401 KAR (Kentucky Administrative Regulations) Chapter 4, Regulation 060, states as a part of the technical requirements for a state floodplain permit: The applicant shall provide cross sections for determining floodway boundaries (and thereby Base Flood Elevations) at any proposed construction site where FEMA maps are not available. All cross sections shall be referenced to mean sea level and shall have vertical error tolerances of no more than + five-tenths (0.5) foot. Cross sections elevations shall be taken at those points which represent significant breaks in slope and at points where hydraulic characteristics of the base floodplain change. Each cross section shall extend across the entire base floodplain and shall be in the number and at the locations specified by the cabinet. If necessary to ensure that significant flood damage will not occur, the cabinet may require additional cross sections or specific site elevations which extend beyond those needed for making routine regulatory floodway boundary calculations. (c) In all other Zones, new construction or substantial improvement shall be elevated one (1) foot above the base flood elevation. Upon the completion of the structure, the elevation of the lowest floor including basement shall be certified by a licensed professional engineer or surveyor, and verified by the community building inspection department to be properly elevated. Such certification and verification shall be provided to the Floodplain Administrator. (2) Nonresidential Construction. New construction or substantial improvement of any commercial, industrial or other nonresidential structure (or manufactured home used for non residential purposes) shall have the lowest floor, including basement, mechanical and electrical equipment, elevated no lower than one (1) foot or greater above the base flood elevation. Ductwork shall be installed above the ceiling unless the finish floor elevation is a minimum of two (2) feet above the base flood elevation and a minimum of two (2) feet above the finish grade. If lowest floor is constructed lower than one (1) foot above the base flood elevation the following provisions shall apply: (a) The structure must be flood-proofed below an elevation one foot above the level of the base flood elevation, provided that all areas of the structure below the required elevation are watertight with walls substantially impermeable to the passage of water: (b) The structure must have all—structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; [(c)] A licensed professional engineer, surveyor or architect shall certify that the standards of this subsection are satisfied. Such certification shall be provided to the official as set forth in Subsection 18-4(c)(7). (3) Elevated Buildings. New construction or substantial improvements of elevated structures on columns, posts, or pilings that include fully enclosed areas formed by foundation and other exterior walls below the base flood elevation shall be designed to preclude finished living space and designed to allow for entry and exit of flood waters to automatically equalize hydrostatic flood forces on exterior walls. (a) Designs for complying with this requirement must either be certified by a professional engineer or architect or meet the following minimum criteria: (i) Provide a minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding: (ii) The bottom of all openings shall be no higher than one foot above foundation interior grade (which must be equal to in elevation or higher than the exterior foundation grade); and, (iii) Openings may be equipped with screens, louvers, valves or other coverings or devices provided they permit the automatic flow of flood waters in both directions. (b) Access to the enclosed area shall be the minimum necessary to allow for parking of vehicles (garage door) or limited storage of maintenance equipment used in connection with the premises (standard exterior door) or entry to the living area (stairway or elevator); and (c) The interior portion of such enclosed area shall not be partitioned or finished into separate rooms. (4) Floodways. Located within areas of special flood hazard established in Subsection 18-3(b) are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of flood waters which carry debris, potential projectiles and has erosion potential, the following provisions shall apply: (a) Prohibit encroachments, including fill, new construction, substantial improvements and other developments unless certification (with supporting technical data) by a licensed professional engineer is provided demonstrating that encroachments shall not result in any increase in flood levels during occurrence of the base flood discharge. (b) If Subsection 18-5(b)(4)(a) is satisfied, all new construction and substantial improvements shall comply with all applicable flood hazard reduction provisions of Section 18-5. (5) Standards for Manufactured Homes and Recreational Vehicles. (a) All new or substantially improved manufactured homes placed on sites located within A, A1-30, AO, AH, and AE on the community's Flood Insurance Rate Map (FIRM) must meet all the requirements for new construction, including elevation and anchoring. Locations include: (i) outside of a manufactured housing park complex or subdivision, (ii) in a new manufactured housing park complex or subdivision, (iii) in an expansion to an existing manufactured housing park complex or subdivision (iv) in an existing manufactured housing park complex or subdivision on which a manufactured home has incurred "substantial damage" as the result of a flood, must meet all the requirements for new construction, including elevation and anchoring, (v) in substantially improved manufactured home park or subdivisions, or (vii) on individual lots or parcels. (b) All manufactured homes placed or substantially improved in an existing manufactured housing park complex or subdivision must be elevated on a permanent foundation so that: (i) The lowest floor of the manufactured home is elevated no lower than one (1) foot above the level of the base flood elevation; (ii) The manufactured home must be securely anchored to the adequately anchored foundation system to resist flotation, collapse and lateral movement; or (iii) In an existing manufactured housing park complex or subdivision on which a manufactured home has incurred "substantial damage" as the result of a flood, any manufactured home placed or substantially improved must meet the standards of Subsection 18-5(b)(5)(b)(i) and (ii) above. (c) All recreational vehicles placed on sites located within A, A1-30, AO, AH, and AE on the community's Flood Insurance Rate Map (FIRM) must either (i) Be on the site for fewer than 180 consecutive days; (ii) Be fully licensed and ready for highway use; or (iii) Meet the permit requirements for new construction of this ordinance, including anchoring and elevation requirements for "manufactured homes". A recreational vehicle is ready for highway use if it is licensed and insured in accordance with the State of Kentucky motor vehicle regulations, is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions. 18-5(c) Standards for Areas of Shallow Flooding (AO Zones). Located within the areas of special flood hazard established in Section 18-3(b) are areas designated as shallow flooding areas. These areas have special flood hazards associated with base flood depths of one to three feet (1'-3') where a clearly defined channel does not exist and where the path of flooding is unpredictable and indeterminate; therefore, the following provisions apply: (1) All new construction and substantial improvements of residential structures shall have the lowest floor, including basement, elevated above the highest adjacent grade, at least as high as the depth number specified on the applicable Flood Insurance Rate Map. If no depth number is specified, the lowest floor, including basement, shall be elevated at least two (2) feet above the highest adjacent grade. (2) All new construction and substantial improvements of nonresidential structures shall: (a) have the lowest floor, including basement, elevated above the highest adjacent grade at least as high as the depth number specified on the applicable Flood Insurance Rate Map. If no depth number is specified, the lowest floor, including basement, shall be elevated at least two (2) feet above the highest adjacent grade, or (b) together with attendant utility and sanitary facilities be completely flood-proofed to or above that level so that any space below that level is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. 18-5(d) Standards for All Subdivision Proposals and Development Plans. (1) All subdivision proposals and development plans shall identify the flood hazard area and the elevation of the base flood and be consistent with the need to minimize flood damage. (2) All subdivision proposals and development plans shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize flood damage. (3) All subdivision proposals and development plans shall have adequate drainage provided to reduce exposure to flood hazards. (4) Base flood elevation data shall be provided for all subdivision proposals, development plans, and other proposed development (including manufactured housing park complexes and subdivisions). When a subdivision proposal, development plan, or other proposed development involves streams where no base flood data has been provided or where base flood data has been provided without floodways, the plat or plan drawings shall be accompanied by a certification and supporting data, as specified in Subsection 18-5(e) below. (5) All subdivision plans will include the elevation of proposed structure(s) and lowest adjacent grade. If the site is filled above the base flood elevation, the lowest floor and lowest adjacent grade elevations shall be certified by a licensed professional engineer, surveyor or architect and provided to the Floodplain Administrator. 18-5(e) Standards for Streams without Established Base Flood Elevations and/or Floodways. Located within the areas of special flood hazard established in Subsection 18-3(b), where streams exist but where no base flood data has been provided or where base flood data has been provided without floodways, the following provisions apply: (1) No encroachments, including fill material or structures, shall be located within areas of special flood hazard, unless certification by a licensed professional engineer is provided demonstrating that the cumulative effects of the proposed development, when combined with all other existing and anticipated development will not increase the water surface elevation of the base flood more than one (1) foot at any point within the community. The engineering certification should be supported by technical data that conforms to standard hydraulic engineering principles. (2) New construction or substantial improvements of buildings shall be elevated or flood-proofed to elevations established in accordance with Subsection 18-4(c)(9). 18-5(f) Standards for Accessory Structures in all Zones Beginning with the Letter A. For all accessory structures in a Special Flood Hazard Areas designated "A" the following provisions shall apply: (1) Structure must be non-habitable; (2) Must be anchored to resist flotation forces; (3) If built below base flood elevation will require flood openings/vents no more than one foot above grade, total openings are to be one square inch per one square foot of floor area, at least two openings required on opposite walls; (4) Built of flood resistant materials below a level above the base flood elevation; (5) Must elevate electrical and mechanical equipment above the base flood elevation; (6) Can only be used for storage or parking; (7) Cannot be modified for a different use after permitting; and, (8) If structure is equipped with a heating system, it must meet the requirements for residential or non-residential construction as per Articles 18-5(b)(1) and 18-5(b)(2)
(Ord. No. 16-2009, § 2, 5-5-2009; Ord. No. 3-2025, § 2(Exh. A), 3-18-2025)
Ask a question about Owensboro law
Corpus searches the Owensboro sections it holds and shows the ones that match, with their citations. Free, no sign-in.
