§ 21.8 — Overlay district building form & development standards
Municipal Code of the City of Owensboro, Kentucky (Codified through Ordinance No. 13-2026, adopted June 16, 2026. (Supp. No. 54, Update 2)) · Owensboro Municipal Code, App. F, art. XXI, § 21.8
Corpus is an independent public-information project, not the official City of Owensboro website. Stable reference: corpuslaw.us/code/fe165c59-0568-401b-89ce-72fbfc7ab6cf
21.8. - Overlay district building form & development standards.
21.81 (HC) Historic Core Overlay District. [image omitted; see the official code] 21.81 (a) Building Placement. [image omitted; see the official code] (i) Build-to Line/Zone (BTL/Z) (Distance from property line to edge of the zone) Front (Type "A" Street/Civic Space) (see #15) | 0' | A Front (Type "B" Street) (see #15) | 0' - 6' (see #1) | B (ii) Setback Front (Type "A" Street/Civic Space) (see #15) | 0' (min. and max) | A Front (Type "B" Street) (see #15) | 0' (min.) 6' (max.) | B Side | 0' min.; (see #2) | C Rear | 5' min. | D (iii) Building Form Building Frontage required along "Type A" street/civic space BTZ | 95% (min.) (see #3) | E Building Frontage required along "Type B" street BTZ | 70% (min.) (see #3) | F 21.81 (b) Height. [image omitted; see the official code] (i) Building minimum | 2 stories min. (ii) Building maximum | 5 stories (see #5 and #6) | K (iii) First floor, floor to floor height | Match adjoining historic building (if any) or no less than 15' (see #4) | M (iv) Upper floor(s), floor to floor height | Match adjoining historic building (if any) or no less than 10' | N 21.81 (c) Commercial Frontage Requirements. (i) Ground floor uses, to a minimum depth of 25', along all streets designated as Type "A" in the Historic Core shall be limited to commercial (retail, restaurant, and office), art/dance/music studio, or civic uses only. Residential and lodging uses may be located behind or above the commercial use. Existing institutional uses are exempt from this standard. However, no new institutional uses shall be permitted on the ground floor of Type "A" Streets. 21.81 (d) Parking. [image omitted; see the official code] (i) Location (distance from property line) At & Above Grade Parking Front setback (Type "A" Street) | Shall be located behind the principal building | O Side setback | 0' min. | P Type "B" Street setback | Min. of 3' behind the building facade along that street | Q Rear setback | 0' min. | R Below Grade Parking Allowed up to R-O-W/Property Line Allowed below Civic Space if providing public parking (ii)Required Parking Spaces No required parking for all uses Notes #1 - Area between the building and the edge of the BTZ at the public sidewalk shall be paved to be flush with the sidewalk. #2 - Side setbacks shall be based on minimum fire separation required between buildings, if applicable. #3 - Corner building street facades must be built to the BTZ for a minimum of 25' from the corner along both streets or the width of the corner lot, whichever is less. Recessed entrances are permitted as long as the upper floors meet the build-to zone or build-to line standards. #4 - First floor heights shall not apply to parking structures. #5 - Attics and mezzanines less than 7' (avg.) height shall not be counted as a story. #6 - Corner buildings may exceed the maximum building height by 15% for 20% of the building's frontage along each corresponding street faéade. [image omitted; see the official code] 21.81 (e) Encroachments (see #13). [image omitted; see the official code] (i) Location Type "A" Street/Civic Space (Front) | 50% of the depth of the sidewalk or 6' (whichever is greater) | U Type "B" street (Side) | 6' max | V Rear | 3' max. | W 21.81 (f) Applicability. Building Form and Development Standards in this section shall apply to new construction, additions, or substantial modifications. Notes #7 - All buildings in the Historic Core shall meet the Historic Preservation Standards & Guidelines in Section 21.8(h). #8 - Any frontage along a public street (except alleys) not defined by a building at the BTZ shall be defined by a 4' high Street Screen. #9 - Parking driveway width | 24' max. (at the throat) | S #10 - Driveways shall not be located on a Type "A" Street unless the property has no feasible access to either a Type "B" Street or a vehicular alley. | T #11 - Shared driveways and cross access easements are encouraged between lots to minimize curb cuts. #12 - Article 13.1 of the Owensboro Metropolitan Zoning Ordinance shall apply for design of off-street parking areas. #13 - Canopies, awnings, signs, galleries, and balconies may encroach over the BTZ and setback areas as indicated in the shaded areas as long as the vertical clearance is a minimum of 8' from the finished sidewalk elevation. In no case shall an encroachment be located over an on-street parking or travel lane. All encroachments over the public R-O-W shall meet standards in Article 21.142(m). #14 - Ground and roof mounted mechanical equipment shall be screened from direct ground level view from adjoining public rights-of-way. In addition to a parapet wall no higher than 42," the perimeter of any visible roof mounted mechanical equipment shall be circumscribed by a wall or permanent screen that is at least as tall as the equipment itself. #15 - Setbacks and build-to lines on recessed entries and arcade buildings shall be measured from the front of faéade with the recessed entry or arcade. #16 - Off-street loading and unloading shall be located along Type "B" Streets or alleys only unless the property has no feasible access to either a Type "B" Street or vehicular alley. 21.81 (g) Historic Preservation Standards. (i) Applicability. These standards shall apply to all building demolitions, renovations and reconstruction to the exterior facades of existing buildings within the Historic Core Overlay District. These standards shall also apply to additions to existing buildings and new construction within the Historic Core Overlay District. Demolitions of existing buildings shall require a Demolition Permit to be obtained from City only after review and approval by the Owensboro Historic Preservation Board (HPB). Appeals to the Demolition review may be made to the Circuit Court of Daviess County. All renovations and reconstructions of building exteriors within this District shall be required to obtain a Certificate of Appropriateness prior to building permit application or commencing the work. The Certificate of Appropriateness may be approved administratively by the Zoning Administrator after compliance review by the Downtown Design Administrator and appealed to the Historic Preservation Board. The following activities (regardless of whether they require building permits) shall require a Certificate of Appropriateness: i. Additions to existing historic structures; or new buildings or outbuildings on sites containing historic structures. ii. Removal and replacement of any architectural detailing. iii. Construction of roof top additions or decks. iv. Alteration of accessory structures such as garages. v. Installation of exterior access stairs. vi. Window or door replacement with or without alteration of the openings. vii. Installation of antennas and satellite receiving dishes that are visible from adjoining public rights-of-way (except alleys). viii. Masonry work; including without exception, spall repair, pointing, sandblasting, chemical cleaning; or surface refinishing. ix. Installation or alteration of any new exterior sign, or alteration of any sign contributing to the significance of a structure. x. Site features other than vegetation, including without exception fencing, lighting and lighting fixtures, paving and grading. xi. Installation of mechanical equipment on the roof and ground, if visible from the street. The following activities shall not require a Certificate of Appropriateness: a. Work which consists solely of ordinary maintenance; b. Emergency repairs of a temporary nature to remedy problems determined by an outside agency that threaten life, health or safety; or, c. Alteration of interior space and finishes of a historic building (Secretary of the Interior Standards may still apply for interior renovations). (ii) Demolitions Demolitions of existing buildings within the Historic Core Overlay District shall only be permitted after review and approval by the Owensboro Historic Preservation Board after a duly advertised Public Hearing. All applications for demolitions shall be reviewed by the Downtown Design Administrator and recommendations shall be forwarded to the HPB. If an application for demolition is denied by the HPB, it may be appealed to the Circuit Court of Daviess County. All appeals shall be taken in the Circuit Court within thirty (30) days after the action or decisions of the Historic Preservation Board and all decisions which have not been appealed within thirty (30) days shall become final. After the appeal is taken, the procedure shall be governed by the rules of civil procedure. When an appeal has been filed, the Clerk of the Circuit Court shall issue a summons to all parties and shall cause it to be delivered for service as in any other law action. A building permit to demolish a building that has been approved for demolition by the HPB may only be granted after the approval of a building permit for new construction on the same property as the building to be demolished, unless the building has been deemed as a public hazard or attractive nuisance. In reviewing and considering applications for building demolitions, the Downtown Design Administrator and the HPB shall consider the following: a. The public's interest in the preservation of the cultural resource. b. Whether the building is locally or nationally designated as a landmark. c. The age of the cultural resource, its uniqueness or uncommon design, texture, and/or material and its ability to be reproduced without unreasonable difficulty and/or expense. d. The ability of the cultural resource to help preserve and protect a historic place or prehistoric site or area of historic interest in the City. e. The ability of the cultural resource to promote the general welfare of the City by: 1) Encouraging the study of American History, architecture and design; 2) Developing an understanding of the importance and value of the American culture and heritage; and 3) Making the City a more attractive and desirable place in which to live. f. Whether the building is being demolished for new construction on the same site which is more economically feasible than restoring the existing structure. An application for demolition may only be approved by the HPB if: a. A building or part of a building is structurally unstable or in a stage of advanced deterioration and has been deemed by the City as a hazard to public safety or an attractive nuisance; or b. A building or part of a building is structurally unstable or in a stage of advanced deterioration and a technical report has been prepared by an architect or professional engineer experienced in rehabilitation of historic structures detailing the building's structural soundness and suitability for rehabilitation including the nature and extent of the specific problems and reasonable cost estimates to rectify them. In addition the following shall be required: • A financial report is submitted with the application detailing the costs of rehabilitation, and evidencing that the existing improvement is incapable of reasonable use or producing an economic return, and • Demolition application is submitted with complete plans for the new development proposed on the site, together with a timetable and a budget for both the demolition and the reconstruction, as well as satisfactory evidence that adequate financing is available. (iii) Renovation of Existing Buildings The following standards shall apply in reviewing and approving applications for Certificates of Appropriateness for renovation of existing buildings within the Historic Core Overlay District. Photographs used in this section are for illustration purposes only. Specifically, they are intended to show how the standards would apply when buildings are renovated and do not impose any requirements on existing buildings. a. Historic Façade. Maintain the original character of the façade of historic building. [image omitted; see the official code] [image omitted; see the official code] b. Horizontal Alignment. Reinforce the established horizontal lines of facades on the block. Restore or recreate the historic horizontal alignment of architectural features such as cornices, window sills and parapets. c. Storefronts. Storefront buildings should maintain the original size, shape, and design of the storefront opening. Large ground floor windows shall be maintained and darkly tinted or mirrored glass is not permitted. Doors shall use painted frames. Window and door frames may be metal with anodized or painted finish or varnished or painted wood. Residential type of opaque and paneled doors shall not be permitted. Unfinished aluminum or stainless steel frames are not permitted. [image omitted; see the official code] d. Recessed Entrances. Maintain traditional recessed storefront entrances where they exist. [image omitted; see the official code] e. Storefront Kickplates. Maintain and/or restore kickplate below storefront windows. Appropriate kickplate materials include painted wood, smooth stone, glazed tile, opaque glass, or painted metal in muted tones. [image omitted; see the official code] f. Façade Elements. Preserve primary façade elements and building materials. If the original façade has been concealed, it shall be uncovered. If portions of the original building material must be replaced, duplicate the material used or use a similar material to the original. Use of "barn" wood or other boarded surfaces which are inconsistent with the original building design shall not be permitted. Materials that are similar in texture, pattern, and color to those of the dominant brick work found in historic buildings shall be required. [image omitted; see the official code] g. Original Ornamentation. Preserve and restore original ornamentation and details of the façade using photographic and other evidence. [image omitted; see the official code] [image omitted; see the official code] h. Upper Story Windows. Along street facing facades, preserve the size and shape of upper story windows. Reopen any blocked upper story windows. Maintain the original spacing of windows. i. Window Materials. Unfinished Aluminum tube type windows, unfinished wood or unfinished stainless steel fames shall not be permitted along any street facing facades. Solid vinyl windows are only permitted as long as the window has a minimum frame depth of 4-1/2," and is fabricated to fit the original window opening size. Vinyl clad wood windows may be permitted. j. Transom. Preserve the original transom, if it exists. The transom shall be clear glass or shall be used for a sign or decorative panel. [image omitted; see the official code] k. Storefront Doors. Maintain and repair the original door or replace with a door of similar design and materials. Standard aluminum and glass commercial doors and frames are permitted. Replacement doors shall be commercial type doors and shall not be of residential proportions or design. [image omitted; see the official code] l. Building Colors. Building color scheme shall visually link the building with others in the area. The colors chosen should relate to the established masonry tones within the Historic Core. BE AWARE that if Historic Tax Credits are being sought, that the Secretary of the Interior Standards may limit whether a building can be painted or existing paint removed. The following shall only be recommendations to follow to develop appropriate building color palettes: Three colors are sufficient to highlight any façade: [image omitted; see the official code] Base Color - is that on the upper walls and piers flanking the storefront. This shall be natural masonry or painted to look as natural as possible. Major Trim - is the color that defines the decorative elements of the building, tying together the upper façade trim and the storefront. The trim color should complement the base color. Major trim elements include the building cornice, storefront cornice, window frames, sills and hoods, and storefront frame, columns, and bulkheads (kickplate). Minor Trim - should enhance the color scheme established by the base and major trim. Often a darker shade of the major trim is used to highlight the window sashes, doors, and selective cornice and bulkhead details. (iv) New Construction and Additions to Existing Buildings Article 21.9 shall apply to the design of new buildings and additions to existing buildings 21.82 (DT-C) Downtown Core Overlay District. [image omitted; see the official code] 21.82 (a) Building Placement. [image omitted; see the official code] (i) Build-to Zone (BTZ) (Distance from property line to edge of the zone) Front (Type "A" Street/Civic Space) | 0' - 6' (see #1) | A Front (Secondary Street) | 0' - 6' (see #1) | B (ii) Setback Front (Type "A" Street/Civic Space) | 0' (min.) 6' (max.) | A Front (Secondary Street) | 0' (min.) 6' (max.) | B Side | 0' min. (see #2) | C Rear | 5' min. | D (iii) Building Form Building Frontage required along "Type A" street/civic space BTZ | 95% (min.) (see #3) | E Building Frontage required along "Type B" street BTZ | 70% (min.) (see #3) | F 21.82 (b) Height. [image omitted; see the official code] (i) | Building minimum | 2 stories min. (ii) | Building maximum | 6 stories (see #4 and #5) | K (iii) | First floor, floor to floor height | 12' min. | M (iv) | Upper floor(s), floor to floor height | 10' min. | N 21.82 (c) Special Requirements. Ground floor uses, to a minimum depth of 25 feet from the front facade of the building, along all streets designated as Type "A" in the Downtown Core shall be limited to commercial (retail, restaurant, or office) or civic uses only. Residential and lodging rooms may be located behind or above the commercial use. Existing institutional uses are exempt from this standard. However, no new institutional uses shall be permitted on the ground floor of Type "A" Streets. 21.82 (d) Parking. [image omitted; see the official code] 1. Location (distance from property line) At Grade Parking Front setback | Shall be located behind the principal structure on the lot | O Side setback | 0' min. | P Type "B" Street setback | Min. of 3' behind the building facade along that street | Q Rear setback | 0' min. | R Below and Above Grade Parking Allowed up to R-O-W/Property Line Allowed below Civic Space if providing public parking 2. Required Parking Spaces No required parking for all uses 21.82 (e) Historic Preservation. Any changes to historic building facades or demolition of or additions to historic buildings in the Downtown Core shall meet the standards established in Article 21.81 (g). 21.82 (f) Encroachments (see #11). [image omitted; see the official code] (i) Location Type "A" Street/Civic Space (Front) | 50% of the depth of the sidewalk or 6' (whichever is greater) | U Type "B" street (Side) | 6' max | V Rear | 3' max. | W 21.82 (g) Applicability. Building Form and Development Standards in this Article shall apply to new construction, additions, or substantial modifications that exceed the threshold established under Article 21.142 (o) Non-Conforming Buildings and Uses except as specified under Historic Preservation in 21.82 (e). Notes #1 - Area between the building and the edge of the BTZ at the public sidewalk shall be paved to be flush with the sidewalk. #2 - Side setbacks shall be based on minimum fire separation required between buildings, if applicable. #3 - Corner building street facades must be built to the BTZ for a minimum of 25' from the corner along both streets or the width of the corner lot, whichever is less. Recessed entrances are permitted as long as the upper floors meet the build-to zone requirements. #4 - Attics and mezzanines less than 7' (avg.) height shall not be counted as a story. #5 - Corner buildings may exceed the maximum building height by 15% for 20% of the building's frontage along each corresponding street façade. [image omitted; see the official code] #6 - Any frontage along a public street (except alleys) not defined by a building at the BTZ shall be defined by a 4' high Street Screen. #7 - Parking driveway width | 24' max. | S #8 - Driveways shall not be located on a Type "A" Street unless the property has no feasible access to either a Type "B" Street or a vehicular alley. | T #9 - Shared driveways and cross access easements are encouraged between lots to minimize curb cuts. #10 - Article 13.1 of the Owensboro Metropolitan Zoning Ordinance shall apply for design of off-street parking areas. #11 - Canopies, awnings, signs, galleries, and balconies may encroach over the BTZ and setback areas as indicated in the shaded areas as long as the vertical clearance is a minimum of 8' from the finished sidewalk elevation. In no case shall an encroachment be located over an on-street parking or travel lane. All encroachments over the public R-O-W shall meet standards in Article 21.142(m). #12 - Setbacks and build-to lines on recessed entries, stoops, and arcade buildings shall be measured from the front of the façade with the recessed entry or arcade. #13 - Ground and roof mounted mechanical equipment shall be screened from direct ground level view from adjoining public rights-of-way. In addition to a parapet wall no higher than 42," the perimeter of any visible roof mounted mechanical equipment shall be circumscribed by a wall or permanent screen that is at least as tall as the equipment itself. #14 - Off-street loading and unloading shall be located along Type "B" Streets or alleys only unless the property has no feasible access to either a Type "B" Street or vehicular alley.
(Ord. No. 8-2015, § 2, 4-21-2015)
Ask a question about Owensboro law
Corpus searches the Owensboro sections it holds and shows the ones that match, with their citations. Free, no sign-in.