§ 21.9 — Building Design Standards
Municipal Code of the City of Owensboro, Kentucky (Codified through Ordinance No. 13-2026, adopted June 16, 2026. (Supp. No. 54, Update 2)) · Owensboro Municipal Code, App. F, art. XXI, § 21.9
Corpus is an independent public-information project, not the official City of Owensboro website. Stable reference: corpuslaw.us/code/7a8bceff-61a3-426f-af33-73d517206781
21.9. - Building Design Standards.
Photographs used in this section are for illustration and informational purposes only. Specifically, they are intended to show how the standards would apply. 21.91 General to all Overlay Character Districts. a. Building Orientation. Buildings shall be oriented towards Type "A" Streets, where the lot has frontage along Type "A" Streets. All other buildings shall be oriented towards Type "B" Streets or Civic Spaces. Primary entrances to buildings shall be located on the street along which the building is oriented. At intersections, corner buildings may have their primary entrances oriented at an angle to the intersection. All primary entrances shall be oriented to the public sidewalk for ease of pedestrian access. Secondary and service entrances may be located from internal parking areas or alleys. [image omitted; see the official code] b. Design of Parking Structures. All frontages of parking structures located on Type "A" Streets shall be lined by active commercial uses on the ground floor to a minimum depth of 25'. Parking structure facades on all public streets (except alleys) shall be designed with both vertical (façade rhythm of 20' - 30') and horizontal (aligning with horizontal elements in the block) articulation. Where above ground structured parking is located at the perimeter of a building; it shall be screened in such a way that cars are not visible from adjacent buildings or the street on all parking levels. Parking garage ramps shall not be visible from any public street. Ideally, ramps should not be located along the perimeter of the parking structure. Architectural screens shall be used to articulate the façade, hide parked vehicles, and shield lighting. [image omitted; see the official code] c. Design of Automobile Related Building and Site Elements. Drive-through lanes for commercial uses shall not be located along or visible from any Type "A" Street. Along Type "B" Streets, no more than two drive-through lanes shall be permitted along that lot's street frontage. Drive-through lanes shall be hidden behind a Street Screen along the Type "B" street frontage. There shall be no limit to the number of drive-through lanes located along alleys. All off-street loading, unloading, and trash pick up areas shall be located along alleys or Type "B" Streets only unless permitted in the specific overlay district building form and development standards in 21.8. Any off-street loading, unloading, or trash pick up areas shall be screened using a 5' (min.) high Street Screen at the BTZ. d. Design of Major Civic Venues. Two major civic venues have been identified in the Downtown Master Plan and locations have been recommended in the Downtown Overlay Regulating Plan. The following standards provide guidance on the design of these large-scale venues to appropriately address transition and impact on Downtown streetscape. The large-scaled buildings shall be articulated horizontally and vertically with architectural elements to break the mass of the structure down. All frontages along Type "A" Streets shall be lined by active commercial uses on the ground floor to a minimum depth of 25'. Major entrances and exits shall be clearly marked and shall front on plazas and wide sidewalks that allow pedestrians safe ingress and egress into the building. Major entrances and key street intersections, including locations recommended for vista terminations, shall be emphasized with vertical elements that create a unique identity to the venue. Public street frontages shall not be blank walls. Windows, changing building materials, arcades, building articulation, and other architectural elements shall be used to add interest at the street level. [image omitted; see the official code] [image omitted; see the official code] 21.92 Specific to Historic Core (new construction and additions only), Downtown Core, Riverfront Core, Riverfront Crossing, and Frederica Boulevard Overlay Character Districts. a. Roof Form. Buildings shall have flat or low pitched (less than 4:12) roofs with parapets (a minimum of 50% of total roof must have parapets and 100% of portion of roof with public street frontage required to have parapets). Mansard roofs shall be prohibited. [image omitted; see the official code] b. Façade Composition. Buildings shall maintain the traditionally prevalent façade rhythm of 20' - 30'. This rhythm may be expressed by changing materials, or color, or by using design elements such as fenestration, columns and pilasters, or by varying the setback of portions of the building façade. [image omitted; see the official code] Building facades shall be designed with a distinct base, middle, and top. For retail storefront buildings, a transom, display window area, and bulkhead at the base shall be utilized. [image omitted; see the official code] Infill buildings shall generally maintain the alignment of horizontal elements along the block. [image omitted; see the official code] Corner emphasizing architectural features, pedimented gabled parapets, cornices, awnings, blade signs, arcades, colonnades and balconies should be used along commercial storefronts to add pedestrian interest. [image omitted; see the official code] c. Windows and Doors. Windows and doors on street (except alleys) fronting facades shall be vertically proportioned that are similar in size and shape to those used historically. Residentially sized (e.g., 3' × 5') and proportioned windows shall not be permitted. [image omitted; see the official code] [image omitted; see the official code] All ground floor front facades for commercial and mixed use buildings along all streets shall have transparent storefront windows covering no less than 65% of the façade area. Each upper floor of the same building façades facing a street or plaza shall contain transparent windows covering at least 35% of the façade area. All other street facing side facades (except alleys), shall have transparent windows covering at least 30% of the façade area for all floors. [image omitted; see the official code] First floor store front windows shall NOT be of a residential type (double hung or casement). First floor windows shall NOT be reflective, tinted or mirrored glass (low E glass is acceptable). d. Building Materials. Historic Core Character District: At least 75% of each street facing façade (except alleys) of all new buildings (excluding doors and windows) shall be externally finished with the traditionally used material of masonry (brick, stone, marble, granite, etc.). Additions to existing buildings, to the extent possible, shall match the existing external finish materials and corresponding proportions of the same. All other non-traditional materials will be considered on a case-by-case basis and may only be approved by the HPB. When any other materials are used, they should appear similar in character to those used traditionally. Such alternative materials should also have demonstrated durability. Downtown Core, Riverfront Core, and Frederica Boulevard Overlay Districts: At least 75% of each street facing (except alleys) façade, of all new buildings (excluding doors and windows) shall be finished in one or more of the following materials: - Masonry (brick, stone, cast stone, rock, marble, granite, or glass block). - Pre-cast concrete panels made to look like stone. Additions to existing buildings, to the extent possible, shall match the existing external finish materials and corresponding proportions of the same. Other materials will be considered as primary building materials on a case-by-case basis and may only be approved by the HPB. No more than 25% of each street facing facade shall use accent materials such as wood, architect metal panel, split-face concrete block, tile, stucco, or Exterior Insulating Finishing System (EIFS). [image omitted; see the official code] Side facades and rear facades (that front on alleys and/or no public streets) shall be of a similar finished quality and color that blend with the front of the building. In addition to the primary and accent façade materials listed above, rear facades may be painted EIFS or painted concrete block matching the same color of the rest of the building if the rear façade faces an alley or is not viewable from a public street or right-of-way. [image omitted; see the official code] Roofing materials visible from any public right-of-way: copper, factory finished standing seam metal, slate, synthetic slate, or similar materials. 21.93 Specific to Riverfront Edge, Downtown Transition, and Downtown Campus Overlay Character District. a. Building Orientation. Garages for Residential Buildings shall be located on alleys at the rear of residential buildings; pull-through garages are allowed if the garage door is set back behind the rear façade of the main structure. If front-loaded garages or carports are utilized on residential uses, the garages and carports shall be no greater than 14 feet wide and set back at least 20 feet measured from the face of the main structure closest to the garage/carport or rotated 90 degrees with windows on the wall facing the street. All garage doors shall be divided into single bays separated by at least a 16-inch pier or column. Front-loaded garages on residential lots less than 40 feet wide shall not be allowed. Town homes and courtyard apartments shall utilize rear-loaded garages. b. Building Massing and Scale. Commercial and Mixed Use Buildings shall be simple, rectilinear forms with flat or low pitched (less than 4:12) roofs with parapets. Residential Buildings shall have relatively flat fronts and simple roofs with most building wing articulations set at the rear of the structure. Window projections, stoops, porches, balconies, and similar extensions are exempt from this standard. Gable roofs, if provided for residential buildings, shall have a minimum pitch of 5/12. When hipped roofs are used, the minimum pitch shall be 5/12. Other roof types shall be appropriate to the architectural style of the building. Porch roofs may be a minimum pitch of 3/12. Mansard roofs shall be prohibited. [image omitted; see the official code] [image omitted; see the official code] c. Façade Composition. Buildings shall maintain the traditionally prevalent façade rhythm of 20' - 30' or multiples thereof. This rhythm may be expressed by changing materials, or color, or by using design elements such as columns and pilasters, or by varying the setback of portions of the building façade. Commercial and Mixed use building facades shall be designed with a distinct base, middle, and top and shall maintain the alignment of horizontal elements along the block. For retail storefronts, a transom, display window area, and bulkhead at the base shall be utilized. Awnings, blade signs, arcades, colonnades, café seating, and balconies should be used along commercial storefronts to add pedestrian interest. Porches, stoops, eaves, and balconies should be added along residential facades to add pedestrian interest along the street. If the residential building is setback less than 10' from the front property line, the grade of the slab or first floor elevation shall be elevated at least 18 inches above the grade of the sidewalk. If the residential structure is setback 10' or more from the front property line and is not elevated above the grade of the sidewalk, a 3' high fence shall be provided at the front property line. Chain link fences shall not be permitted along the front property line in any Overlay District. Plastic vinyl fences shall also not be permitted in the Riverfront Edge and Downtown Campus Overlay Districts. [image omitted; see the official code] d. Windows and Doors. Windows and doors shall be vertically oriented. Windows may have jack arch, keystone arch, flat arch, or ornamental arches. [image omitted; see the official code] All ground floor front building facades for commercial and mixed use buildings along all streets shall have transparent storefront windows covering no less than 65% of the façade area. Each upper floor of the same building façades facing a street or plaza shall contain transparent windows covering at least 35% of the façade area. All other street facing side facades (except alleys), shall have transparent windows covering at least 30% of the façade area for all floors. All building facades of residential buildings fronting on all streets or civic/open spaces, except alleys, shall have transparent windows covering at least 30% of each façade. e. Building Materials. Commercial and Mixed Use Buildings: The following materials shall NOT be permitted on any façade: - Use of lap or shingle siding of any material including wood, vinyl, cementious, or painted or corrugated metal, or roofing materials. At least 60% of the street facing (except alleys) facades of all new buildings (excluding doors and windows) shall be finished in one or more of the following materials: - Masonry (brick, stone, terra cotta, cast stone, rock, marble, granite, glass block and/or tile). - Split face concrete block or pre-cast, or poured in place concrete. - Cementitious-fiber clapboard (not sheet) with at least a 50-year warranty may only be used on the upper floors. - Tilt-up concrete panels that have a grid like appearance - Architectural metal panels Other materials will be considered as primary building materials on a case-by-case basis and may only be approved by the HPB. No more than 40% of the street facing facades shall use accent materials such as wood, metal, stucco, or Exterior Insulating Finishing System (EIFS). Side facades and rear facades (that do not front on any streets) shall be of finished quality and of the same color and materials that blend with the front of the building. Rear facades may be painted EIFS or painted concrete block matching the same color of the rest of the building if the rear façade faces an alley or is not viewable from a public street or right-of-way. [image omitted; see the official code] Residential Buildings: The following shall be permitted finishes for all street fronting facades (except alleys) of residential buildings. No more than three different materials shall be used on any single facade: • Cementitious-fiber clapboard (not sheet) with at least a 50-year warranty; • Lap-sided wood; • Masonry (brick; stone; man-made stone, or stucco utilizing a three-step process). • Vinyl siding (permitted in Downtown Transition Character District only) • Architectural metal panels The following may only be allowed up to 40% as an accent material: • Exterior Insulating Finishing System (EIFS) or similar material over a cementitious base, rock, glass block and tile. Side and rear facades shall be of finished quality and of the same color and materials that blend with the front of the building. Roofing materials (visible from any public right-of-way): copper, factory finished painted metal, slate, synthetic slate, terra cotta, and asphalt shingles. 21.94 Specific to Neighborhood Overlay Character District. a. Building Orientation. Garages for Residential Buildings shall be located on alleys at the rear of residential buildings; pull-through garages are allowed if the garage door is set back behind the rear façade of the main structure. If front-loaded garages or carports are utilized on residential uses, the garages and carports shall be no greater than 12 feet wide and set back at least 20 feet measured from the face of the main structure closest to the garage/carport or rotated 90 degrees with windows on the wall facing the street. On corner lots, the garage may be rotated with windows facing the primary street with driveway access from the secondary street. All garage doors shall be divided into single bays separated by at least a 16-inch pier or column. Front-loaded garages on residential lots less than 40 feet wide shall not be allowed. Town homes and courtyard apartments shall utilize rear-loaded garages. Residential Buildings shall have relatively flat fronts and simple roofs with most building wing articulations set at the rear of the structure. Window projections, stoops, porches, balconies, and similar extensions are exempt from this standard. Gable roofs, if provided for residential buildings, shall have a minimum pitch of 5/12. When hipped roofs are used, the minimum pitch shall be 5/12. Other roof types shall be appropriate to the architectural style of the building. Porch roofs may be a minimum pitch of 3/12. Mansard roofs shall be prohibited. [image omitted; see the official code] [image omitted; see the official code] b. Façade Composition. On residential buildings, at least one of the following shall be utilized: porches, stoops, bay windows, balconies, masonry clad chimneys, attached pergolas or colonnades. Those architectural elements may encroach beyond the setback line. If the residential structure is setback less than 10' from the front property line, the grade of the slab or first floor elevation shall be at least 18 inches above the grade of the sidewalk. If the residential structure is setback 10' or more from the front property line and is not elevated above the grade of the sidewalk, a 3' high fence shall be provided at the front property line. Chain link fences shall not be permitted along the front property line. Architectural embellishments that add visual interest to the roofs, such as dormers and masonry chimneys may be provided. All new residential buildings shall have windows or doors covering no less than 30% of all street facing façades. If window shutters are used they shall be approximately half the window width and the same height of the associated opening (including casing for masonry walls; not including casing for siding walls). All shutters shall be louvered, paneled, or constructed of boards as appropriate to the style of the building. c. Building Materials. The following shall be permitted finishes for all street fronting facades (except alleys) of residential buildings. No more than three different materials shall be used on any single facade: • Cementitious-fiber clapboard (not sheet) with at least a 50-year warranty; • Lap-sided wood; • Masonry (brick; stone; man-made stone, or stucco utilizing a three-step process). • Vinyl siding • Architectural metal panels The following may only be allowed up to 40% as an accent material: • Exterior Insulating Finishing System (EIFS) or similar material over a cementitious base, rock, glass block and tile. Side and rear facades shall be of finished quality and of the same color and materials that blend with the front of the building. Roofing materials (visible from any public right-of-way): copper, factory finished painted metal, slate, synthetic slate, terra cotta, and asphalt shingles.
(Ord. No. 8-2015, § 2, 4-21-2015)
Ask a question about Owensboro law
Corpus searches the Owensboro sections it holds and shows the ones that match, with their citations. Free, no sign-in.
