For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 11.5 — Improvements

Code of Ordinances of the City of Bossier City, Louisiana (Codified through Ordinance No. 182-2025, adopted December 2, 2025 (Supp. No. 23)) · Bossier City Code of Ordinances § 11.5

Corpus is an independent public-information project, not the official City of Bossier City website. Stable reference: corpuslaw.us/code/6f02a5e3-8e81-41a7-9752-550c71b985e3

Sec. 11.5 - Improvements.

11.5.1 General Public Improvement Standards. A. All public improvements, including but not limited to streets, curbs, gutters, storm sewers and storm drainage, shall comply with the construction standards established by the Bossier City or Bossier Parish Engineer. Such standards, when higher than those specified in this Code or in the Comprehensive Plan, are incorporated herein by reference. B. Construction of improvements for projects within Bossier City shall not be commenced until a Project Permit has been issued by the City Engineer. C. Sufficient grade and alignment stakes shall be set by a licensed professional engineer or licensed land surveyor to assure compliance with plan, profile and drainage of streets and other proposed public improvements, and submitted with the final plat for approval by the Bossier City or Bossier Parish Engineer. D. Compliance with the items listed above and use of appropriate construction methods shall be determined by the Bossier City or Bossier Parish engineer, as applicable. The developer shall comply with any applicable permitting and fee requirements. 11.5.2 Streets. A. Bossier City and the Village Development Areas. Subdivision streets located within Bossier City and areas designated as Village Development Areas in the Comprehensive Plan shall be paved with Portland cement concrete or a combination of asphalt and concrete and constructed to comply with standards adopted by the Bossier City Engineer. B. Rural Area. Subdivision streets located within the Rural Area, at a minimum, shall be constructed to the adopted Bossier Parish roadway standards. 11.5.3 Sidewalks and Pedestrian Ways. A. Required Sidewalks. Sidewalks shall be provided in accordance with Table 11.4.5a. 1. Within the corporate limits of Bossier City, sidewalks shall be installed and completed concurrently with the street. B. Minimum Width and Alignment. Minimum required sidewalks are indicated in Table 11.4.5a. However, width and location of a new sidewalk may be varied to match the width and location of existing sidewalks in the area, provided the sidewalk width is not to less than 4 feet. C. Construction Material and Thickness. Sidewalk construction shall be of non-reinforced Portland cement concrete with a minimum thickness of 4 inches, over 4 inches of compacted sand. Sidewalks shall have a uniform texture with a broom finish. D. Grades and Ramps. 1. Sidewalk slopes may be varied to match the general topography of the area; however, transitions should be gradual. 2. The elevations of a new sidewalk shall match exactly with the elevation of any existing sidewalk at the point of connection. 3. Sidewalks shall provide a curb ramp for accommodation of the handicapped at all intersections and designated crossings. E. Trails. With approval of the Metropolitan Planning Commission, hiking and bicycle trails may be substituted for sidewalks under certain situations where a subdivision is located near a recreational facility or existing trail system. Trail design shall conform to the requirements of the City or Parish Engineer. 11.5.4 Sewers and Sewage Treatment. A. Septic Tanks. 1. Septic tanks are strongly discouraged in any new subdivision that is platted within the Bossier City limits or in the following areas: a. Areas indicated as wetlands or that are located below the 100-year flood plain elevation in the Comprehensive Plan. b. Any area designated as a "Village Development Area" in the Comprehensive Plan. 2. Septic tanks may be permitted for new subdivisions in remaining unincorporated areas of the Bossier City-Parish MPC planning area, subject to the following minimum lot area standards: a. For lots that use well water as the primary potable water source, the minimum lot area for septic tank use is 1 acre. b. For all other lots, the minimum lot area requirement for septic tank use is 22,500 square feet. c. Any portion of land located within the 100-year floodplain shall not be counted calculating lot area for the purpose of meeting minimum lot area requirements for septic tank use. d. In situations where septic systems are permitted, no subdivision shall receive final approval until the developer has presented evidence that percolation conditions for each lot have been approved by the Louisiana Department of Health. B. Community Sewage Systems. 1. Community sewage collection and treatment facilities (including lagoons) shall be provided for any such land and shall be approved by the Louisiana Health Department and shall be designed to allow for future connection to a public sewer system. 2. Maintenance of such facilities shall be provided by a homeowner's association, special purpose district, or other appropriate entity. Evidence shall be submitted at the time of subdivision approval showing the establishment of such an entity to be responsible for maintenance and management of the system. C. Bossier City Sewer System. Subdivisions connecting to the Bossier City sanitary sewer system shall meet the appropriate size requirements and design standards specified by the City Engineer. 11.5.5 Drainage and Stormwater Management. Drainage ditches, storm sewers, storm drainage courses and stormwater detention facilities shall comply with the design standards established by the City or Parish Engineer, as applicable. 11.5.6 Water Distribution and Supply. A. Individual Wells. 1. Individual wells are discouraged within the Bossier City limits. 2. Individual wells are strongly discouraged in any new subdivisions platted within 1,000 feet of the Bossier City limits or in unincorporated areas designated as a "Village Development Area" in the Comprehensive Plan. 3. If a public water supply is not available to the subdivision, any alternate water supplies must be approved by the Louisiana Health Department. B. Bossier City Water System. Subdivisions connecting to the Bossier City water system shall comply with the requirements of the City Engineer and Fire Department. 11.5.7 Electrical Service, Cable Service, Gas, and Telephone. For subdivisions located within the Bossier City limits or areas designated as a "Village Development Area," telephone, cable television and electrical lines shall be located underground. 11.5.8 Street Lighting. Street lights shall be provided by the developer and shall comply with all AEP/SWEPCO standards and the following requirements: A. Output and Mounting Height. 1. Within the Bossier City limits or areas designated as a "Village Development Area," street lighting shall be installed in compliance with the Bossier City municipal street lighting ordinance. 2. In remaining unincorporated areas of Bossier Parish the required lumen output and mounting height shall be as follows: Table 11.5.8 Street Lighting Standards Street Classification | Bossier City and Village Development Areas | Remaining Areas of the MPC Jurisdiction Mounting Height | Output (lumens ASA) | Distribution Pattern | Mounting Height | Output (lumens ASA) | Distribution Pattern Local | Varies | 9,500 | Type III or V | Varies | 8,500 | Type III or V Collector | 9,500—16,000 | Type III, IV or V | 14,500 | Type III Arterial | 30,000 | Type III or V | 23,000 | Type III B. Light Source. The light source shall be high pressure sodium or metal halide lamps with output Lumens as follows: 100 W HPS | 9,500 Lumens 150 W HPS | 16,500 Lumens 250 W HPS | 30,000 Lumens 400 W HPS | 50,000 Lumens 175 W HPS | 14,000 Lumens C. Location of Street Lights. The general criteria for location of street lights shall be as follows: 1. Within Residential Subdivisions in Bossier City, Bossier Parish and designated Village Development Areas, street lights shall be installed on metal or concrete standards and serviced by underground cable. Under normal conditions, streetlights shall be located at all street intersections and on the right-of-way spaced not to exceed 300' intervals. 2. Within the city limits of the City of Bossier City, Commercial and Industrial subdivisions or any development involving public or private street improvements shall have street lighting as described in the paragraph above with the exception that overhead cables and wooden poles can be utilized with the approval of the City Engineer. 11.5.9 Landscaping. Landscaping shall comply with applicable requirements of Article 13 of this Code.

Ask a question about Bossier City law

Corpus searches the Bossier City sections it holds and shows the ones that match, with their citations. Free, no sign-in.